Action not permitted
Modal body text goes here.
Modal Title
Modal Body
VDE-2026-160
Vulnerability from csaf_helmholzgmbhcokg - Published: 2026-11-10 10:00 - Updated: 2026-11-10 10:00PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31005 | — | ||
| Unresolved product id: CSAFPID-31006 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31001 | — | ||
| Unresolved product id: CSAFPID-31002 | — |
PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "Critical"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "Helmholz myREX24V2/myREX24V2.virtual ships with a bundled PHP version that is affected by two vulnerabilities known as \"php2shell\".",
"title": "Summary"
},
{
"category": "description",
"text": "Both vulnerabilities can lead to unauthenticated remote code execution (RCE) resulting in a total loss of confidentiality, integrity and availability.",
"title": "Impact"
},
{
"category": "description",
"text": "Update the myREX24V2/myREX24V2.virtual instance to version 2.21.6.",
"title": "Remediation"
},
{
"category": "legal_disclaimer",
"text": "Helmholz shall not be held responsible for any indirect, incidental, special, or consequential damages arising from the distribution or use of this document, or from any actions taken in reliance upon its contents. The information contained herein is provided by Helmholz in good faith and free of charge. To the extent permitted under applicable law, such information does not constitute any representation, warranty, guarantee, contractual commitment, or legal obligation on the part of Helmholz. Users remain solely responsible for evaluating the suitability and impact of the information on their specific systems or installations prior to implementation. If any adverse effects are identified, the information must not be applied.",
"title": "Disclaimer"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@helmholz.de",
"name": "Helmholz GmbH \u0026 Co. KG",
"namespace": "https://www.helmholz.de"
},
"references": [
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Helmholz",
"url": "https://certvde.com/en/advisories/vendor/helmholz"
},
{
"category": "self",
"summary": "VDE-2026-160: Helmholz: php2shell in myREX24V2/myREX24V2.virtual - HTML",
"url": "https://certvde.com/en/advisories/VDE-2026-160"
},
{
"category": "self",
"summary": "VDE-2026-160: Helmholz: php2shell in myREX24V2/myREX24V2.virtual - CSAF",
"url": "https://helmholz.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-160.json"
}
],
"title": "Helmholz: php2shell in myREX24V2/myREX24V2.virtual",
"tracking": {
"aliases": [
"VDE-2026-160",
"SIM#2026-06"
],
"current_release_date": "2026-11-10T10:00:00.000Z",
"generator": {
"date": "2026-11-09T09:27:57.819Z",
"engine": {
"name": "Secvisogram",
"version": "2.6.16"
}
},
"id": "VDE-2026-160",
"initial_release_date": "2026-11-10T10:00:00.000Z",
"revision_history": [
{
"date": "2026-11-10T10:00:00.000Z",
"number": "1.0.0",
"summary": "Initial revision."
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_family",
"name": "myREX24V2",
"product": {
"name": "Helmholz myREX24V2",
"product_id": "CSAFPID-11001",
"product_identification_helper": {
"cpe": "cpe:2.3:h:helmholz:myREX24V2:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "myREX24V2.virtual",
"product": {
"name": "Helmholz myREX24V2.virtual",
"product_id": "CSAFPID-11002",
"product_identification_helper": {
"cpe": "cpe:2.3:h:helmholz:myREX24V2virtual:*:*:*:*:*:*:*:*"
}
}
}
],
"category": "product_family",
"name": "Hardware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.0.0|\u003c2.21.6",
"product": {
"name": "Firmware \u003c2.21.6",
"product_id": "CSAFPID-21001",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2_firmware:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "2.21.6",
"product": {
"name": "Firmware 2.21.6",
"product_id": "CSAFPID-21002",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2_firmware:2.21.6:*:*:*:*:*:*:*"
}
}
}
],
"category": "product_family",
"name": "Firmware"
}
],
"category": "vendor",
"name": "Helmholz"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-31005",
"CSAFPID-31006"
],
"summary": "Fixed products."
},
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002"
],
"summary": "Affected products"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware \u003c2.21.6 installed on Helmholz myREX24V2",
"product_id": "CSAFPID-31001",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2_firmware:*:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware \u003c2.21.6 installed on Helmholz myREX24V2.virtual",
"product_id": "CSAFPID-31002",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2virtual:*:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware 2.21.6 installed on Helmholz myREX24V2",
"product_id": "CSAFPID-31005",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2_firmware:2.21.6:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware 2.21.6 installed on Helmholz myREX24V2.virtual",
"product_id": "CSAFPID-31006",
"product_identification_helper": {
"cpe": "cpe:2.3:o:helmholz:myREX24V2virtual:2.21.6:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11002"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-109618",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"CSAFPID-31005",
"CSAFPID-31006"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 9.2 / Critical",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update the myREX24V2/myREX24V2.virtual instance to version 2.21.6.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "RCE via OOM corruption"
},
{
"cve": "CVE-2026-109619",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"CSAFPID-31005",
"CSAFPID-31006"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 9.2 / Critical",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update the myREX24V2/myREX24V2.virtual instance to version 2.21.6.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "RCE via stale global state"
}
]
}
CVE-2026-109618 (GCVE-0-2026-109618)
Vulnerability from cvelistv5 – Published: 2026-10-21 13:48 – Updated: 2026-11-16 15:18| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109618",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:46.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109618 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-11-15T00:15:58.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
},
{
"url": "http://seclists.org/fulldisclosure/2026/Oct/51"
},
{
"url": "https://github.com/rapid7/metasploit-framework/pull/22139"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:23.272Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "finder",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
}
],
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:48:34.845Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via OOM corruption",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109618",
"datePublished": "2026-10-21T13:48:34.845Z",
"dateReserved": "2026-10-12T21:03:58.117Z",
"dateUpdated": "2026-11-16T15:18:23.272Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-109619 (GCVE-0-2026-109619)
Vulnerability from cvelistv5 – Published: 2026-10-21 13:54 – Updated: 2026-11-16 15:18| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109619",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:47.838Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109619 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-10-23T14:07:57.152Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:24.606Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:54:43.866Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via stale global state",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109619",
"datePublished": "2026-10-21T13:54:43.866Z",
"dateReserved": "2026-10-12T21:04:00.504Z",
"dateUpdated": "2026-11-16T15:18:24.606Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.