CVE-2026-118460 (GCVE-0-2026-118460)

Vulnerability from cvelistv5 – Published: 2026-11-09 11:48 – Updated: 2026-11-12 16:07
VLAI
Title
AIS embedded private keys enable practitioner impersonation
Summary
Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-12 16:07 UTC
CWE
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-118460",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-11-12T16:07:00.394183Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-11-12T16:07:25.645Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.farmaci",
          "product": "Infantia",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "6.09.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.farmaci",
          "product": "Profim",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "6.09.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.farmaci",
          "product": "Venere",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "6.09.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.farmaci",
          "product": "Phronesis",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "6.09.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.common",
          "product": "Infantia",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "5.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.common",
          "product": "Profim",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "5.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.common",
          "product": "Venere",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "5.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "packageName": "cgm.it.ais.common",
          "product": "Phronesis",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThanOrEqual": "5.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marco Sala"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "CSIRT-IT"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "ApoCert srl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
            }
          ],
          "value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "exploitMaturity": "UNREPORTED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-11-09T11:48:31.899Z",
        "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "shortName": "ENISA"
      },
      "references": [
        {
          "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
        },
        {
          "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "AIS embedded private keys enable practitioner impersonation",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
    "assignerShortName": "ENISA",
    "cveId": "CVE-2026-118460",
    "datePublished": "2026-11-09T11:48:31.899Z",
    "dateReserved": "2026-10-28T08:46:25.411Z",
    "dateUpdated": "2026-11-12T16:07:25.645Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-118460",
      "date": "2026-11-16",
      "epss": "0.00249",
      "percentile": "0.16344"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.farmaci",
                "product": "Infantia",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "6.09.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.farmaci",
                "product": "Profim",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "6.09.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.farmaci",
                "product": "Venere",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "6.09.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.farmaci",
                "product": "Phronesis",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "6.09.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.common",
                "product": "Infantia",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.common",
                "product": "Profim",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.common",
                "product": "Venere",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "packageName": "cgm.it.ais.common",
                "product": "Phronesis",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
          }
        ],
        "id": "CVE-2026-118460",
        "lastModified": "2026-11-12T20:07:11.090",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "UNREPORTED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-118460",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-11-12T16:07:00.394183Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-11-09T12:16:36.863",
        "references": [
          {
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
          },
          {
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
          }
        ],
        "sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-321"
              }
            ],
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-118460",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-12T16:07:00.394183Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-12T16:07:20.646Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.farmaci",
              "product": "Infantia",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "6.09.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.farmaci",
              "product": "Profim",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "6.09.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.farmaci",
              "product": "Venere",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "6.09.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.farmaci",
              "product": "Phronesis",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "6.09.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.common",
              "product": "Infantia",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.common",
              "product": "Profim",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.common",
              "product": "Venere",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "packageName": "cgm.it.ais.common",
              "product": "Phronesis",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marco Sala"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CSIRT-IT"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "ApoCert srl"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
                }
              ],
              "value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-09T11:48:31.899Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
            },
            {
              "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AIS embedded private keys enable practitioner impersonation",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-118460",
        "datePublished": "2026-11-09T11:48:31.899Z",
        "dateReserved": "2026-10-28T08:46:25.411Z",
        "dateUpdated": "2026-11-12T16:07:25.645Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…