Search

Find a vulnerability

Search criteria

    68 vulnerabilities by iconics

    CVE-2024-9852 (GCVE-0-2024-9852)

    Vulnerability from nvd – Published: 2024-11-28 22:20 – Updated: 2026-04-08 13:38
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 18:39 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    References
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS32 Affected: all versions
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS32 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-9852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T18:39:20.927830Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T18:43:35.929Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:38:42.201Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-9852",
        "datePublished": "2024-11-28T22:20:28.303Z",
        "dateReserved": "2024-10-11T01:20:49.722Z",
        "dateUpdated": "2026-04-08T13:38:42.201Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-8300 (GCVE-0-2024-8300)

    Vulnerability from nvd – Published: 2024-11-28 22:18 – Updated: 2026-01-09 07:52
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64 and ICONICS Suite
    Summary
    Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 18:50 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation GENESIS64 Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    iconics genesis64 Affected: 10.97.2
    Affected: 10.97.2cfr1
    Affected: 10.97.2cfr2
    Affected: 10.97.3
        cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric genesis64 Affected: 10.97.2
    Affected: 10.97.2cfr1
    Affected: 10.97.2cfr2
    Affected: 10.97.3
        cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "10.97.2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr1"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.3"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "status": "affected",
                    "version": "10.97.2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr1"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.3"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8300",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T18:50:37.535229Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T18:53:27.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-561",
                  "description": "CWE-561 Dead Code",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T07:52:13.107Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64 and ICONICS Suite",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-8300",
        "datePublished": "2024-11-28T22:18:28.358Z",
        "dateReserved": "2024-08-29T06:26:41.397Z",
        "dateUpdated": "2026-01-09T07:52:13.107Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-8299 (GCVE-0-2024-8299)

    Vulnerability from nvd – Published: 2024-11-28 22:16 – Updated: 2026-04-08 13:35
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 16:37 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8299",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T16:37:52.677330Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T16:40:42.486Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:35:35.670Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-8299",
        "datePublished": "2024-11-28T22:16:31.396Z",
        "dateReserved": "2024-08-29T06:26:34.979Z",
        "dateUpdated": "2026-04-08T13:35:35.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-7587 (GCVE-0-2024-7587)

    Vulnerability from nvd – Published: 2024-10-22 22:19 – Updated: 2026-01-09 05:46
    VLAI
    Title
    Information Disclosure, Information Tampering and Denial of Service (DoS) Vulnerability in GENESIS64, ICONICS Suite, MC Works64, and GENESIS32
    Summary
    Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-23 14:15 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThanOrEqual": "10.97.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7587",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-23T14:15:49.960141Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T15:50:04.628Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.70.300.23 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.70.300.23 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32."
                }
              ],
              "value": "Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Information Disclosure, Information Tampering and Denial of Service (DoS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276 Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:46:11.126Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU95548104"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-296-01"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure, Information Tampering and Denial of Service (DoS) Vulnerability in GENESIS64, ICONICS Suite, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-7587",
        "datePublished": "2024-10-22T22:19:20.646Z",
        "dateReserved": "2024-08-07T08:06:04.877Z",
        "dateUpdated": "2026-01-09T05:46:11.126Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1574 (GCVE-0-2024-1574)

    Vulnerability from nvd – Published: 2024-07-04 09:02 – Updated: 2026-04-08 13:31
    VLAI
    Summary
    Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-05 14:44 UTC
    CWE
    • CWE-470 - Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS32 Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS32 Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions BizViz Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation BizViz Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 10.97 , < 10.97.92 (custom)
        cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , ≤ * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "10.97.92",
                    "status": "affected",
                    "version": "10.97",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-05T14:44:19.238774Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T14:45:36.502Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.447Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-470",
                  "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:31:05.753Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1574",
        "datePublished": "2024-07-04T09:02:35.260Z",
        "dateReserved": "2024-02-16T01:30:45.960Z",
        "dateUpdated": "2026-04-08T13:31:05.753Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1573 (GCVE-0-2024-1573)

    Vulnerability from nvd – Published: 2024-07-04 08:59 – Updated: 2026-04-13 22:47
    VLAI
    Summary
    Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-05 14:46 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions IoTWorX Affected: version 10.95
    Create a notification for this product.
    Mitsubishi Electric Corporation IoTWorX Affected: version 10.95
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 10.97 , < 10.97.92 (custom)
        cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , ≤ * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "10.97.92",
                    "status": "affected",
                    "version": "10.97",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1573",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-05T14:46:51.356597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T14:46:55.563Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.409Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "version 10.95"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "version 10.95"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
                }
              ],
              "value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-13T22:47:17.575Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1573",
        "datePublished": "2024-07-04T08:59:44.079Z",
        "dateReserved": "2024-02-16T01:30:41.285Z",
        "dateUpdated": "2026-04-13T22:47:17.575Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1182 (GCVE-0-2024-1182)

    Vulnerability from nvd – Published: 2024-07-04 08:53 – Updated: 2026-04-08 13:28
    VLAI
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-19 15:23 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:33:24.701Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1182",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-19T15:23:47.078975Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-19T15:25:49.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:28:11.189Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1182",
        "datePublished": "2024-07-04T08:53:41.217Z",
        "dateReserved": "2024-02-02T00:20:48.886Z",
        "dateUpdated": "2026-04-08T13:28:11.189Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-26314 (GCVE-0-2024-26314)

    Vulnerability from nvd – Published: 2024-07-02 00:00 – Updated: 2025-03-21 20:37
    VLAI
    Summary
    Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 16:03 UTC
    CWE
    • n/a
    • CWE-269 - Improper Privilege Management
    Impacted products
    Vendor Product Version
    mitsubishielectric cpu_module_logging_configuration_tool Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_works2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric cw_configurator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric data_transfer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric ezsocket Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:ezsocket:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fr_configurator_sw3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fr_configurator2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    iconics genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_designer3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_softgot1000 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_softgot2000 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_developer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_logviewer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_works3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric melsoft_navigator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mi_configurator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mi_configurator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fcsb1224 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fcsb1224:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mr_configurator2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mr_configurator2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mrzjw3-mc2-utl Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mx_component Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mx_opc_server_da\/ua Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mx_opc_server_da\/ua:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric px_developer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric rt_toolbox3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric rt_visualbox Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:rt_visualbox:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric c_controller_module_setting_and_monitoring_tool Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw0dnc-mneth-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccbd2-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccief-j Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccief-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-mnetg-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-mnetg-b:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-qsccf-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnd-emsdk-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cpu_module_logging_configuration_tool",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cw_configurator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "data_transfer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:ezsocket:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ezsocket",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fr_configurator_sw3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fr_configurator2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_designer3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_softgot1000",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_softgot2000",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_developer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_logviewer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "melsoft_navigator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mi_configurator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mi_configurator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fcsb1224:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fcsb1224",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mr_configurator2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mr_configurator2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mrzjw3-mc2-utl",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mx_component",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mx_opc_server_da\\/ua",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "px_developer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "rt_toolbox3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:rt_visualbox:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "rt_visualbox",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "c_controller_module_setting_and_monitoring_tool",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw0dnc-mneth-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccbd2-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccief-j",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccief-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-mnetg-b:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-mnetg-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-qsccf-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnd-emsdk-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26314",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T16:03:22.624752Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-21T20:37:15.710Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.173Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jungo.com/windriver/versions/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-02T15:39:18.038Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://jungo.com/windriver/versions/"
            },
            {
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26314",
        "datePublished": "2024-07-02T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2025-03-21T20:37:15.710Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40264 (GCVE-0-2022-40264)

    Vulnerability from nvd – Published: 2022-12-13 23:32 – Updated: 2025-04-18 14:46
    VLAI
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-18 14:45 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:40.199Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-014_en.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU95858406/index.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://iconics.com/About/Security/CERT"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40264",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-18T14:45:23.695408Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-18T14:46:00.625Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "ICONICS and Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.96 to 10.97.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker."
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-13T23:32:57.049Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-014_en.pdf"
            },
            {
              "url": "https://jvn.jp/vu/JVNVU95858406/index.html"
            },
            {
              "url": "https://iconics.com/About/Security/CERT"
            },
            {
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-01"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-40264",
        "datePublished": "2022-12-13T23:32:57.049Z",
        "dateReserved": "2022-09-08T19:40:16.930Z",
        "dateUpdated": "2025-04-18T14:46:00.625Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-33320 (GCVE-0-2022-33320)

    Vulnerability from nvd – Published: 2022-07-20 16:56 – Updated: 2026-01-09 05:16
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:16:27.798Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33320",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33320",
        "datePublished": "2022-07-20T16:56:24.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:16:27.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33319 (GCVE-0-2022-33319)

    Vulnerability from nvd – Published: 2022-07-20 16:58 – Updated: 2026-01-09 05:14
    VLAI
    Summary
    Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
                }
              ],
              "value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:14:32.690Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33319",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33319",
        "datePublished": "2022-07-20T16:58:49.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:14:32.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33318 (GCVE-0-2022-33318)

    Vulnerability from nvd – Published: 2022-07-20 16:57 – Updated: 2026-01-09 05:12
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:12:41.871Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33318",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33318",
        "datePublished": "2022-07-20T16:57:38.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:12:41.871Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33317 (GCVE-0-2022-33317)

    Vulnerability from nvd – Published: 2022-07-20 16:53 – Updated: 2026-01-09 05:09
    VLAI
    Summary
    Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.143Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
                }
              ],
              "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:09:15.556Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33317",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Inclusion of Functionality from Untrusted Control Sphere"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33317",
        "datePublished": "2022-07-20T16:53:59.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:09:15.556Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33316 (GCVE-0-2022-33316)

    Vulnerability from nvd – Published: 2022-07-20 16:51 – Updated: 2026-01-09 05:07
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.142Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:07:12.066Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33316",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33316",
        "datePublished": "2022-07-20T16:51:27.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:07:12.066Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33315 (GCVE-0-2022-33315)

    Vulnerability from nvd – Published: 2022-07-20 16:55 – Updated: 2026-01-09 04:58
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:01:20.500Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T04:58:25.913Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33315",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33315",
        "datePublished": "2022-07-20T16:55:13.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T04:58:25.913Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-29834 (GCVE-0-2022-29834)

    Vulnerability from nvd – Published: 2022-07-20 16:48 – Updated: 2026-01-09 04:54
    VLAI
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen.
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T06:33:42.679Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen."
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T04:54:48.324Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-29834",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97 to 10.97.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-29834",
        "datePublished": "2022-07-20T16:48:46.000Z",
        "dateReserved": "2022-04-27T00:00:00.000Z",
        "dateUpdated": "2026-01-09T04:54:48.324Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-9852 (GCVE-0-2024-9852)

    Vulnerability from cvelistv5 – Published: 2024-11-28 22:20 – Updated: 2026-04-08 13:38
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 18:39 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    References
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS32 Affected: all versions
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.3 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS32 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-9852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T18:39:20.927830Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T18:43:35.929Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:38:42.201Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-9852",
        "datePublished": "2024-11-28T22:20:28.303Z",
        "dateReserved": "2024-10-11T01:20:49.722Z",
        "dateUpdated": "2026-04-08T13:38:42.201Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-8300 (GCVE-0-2024-8300)

    Vulnerability from cvelistv5 – Published: 2024-11-28 22:18 – Updated: 2026-01-09 07:52
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64 and ICONICS Suite
    Summary
    Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 18:50 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation GENESIS64 Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: Version 10.97.2
    Affected: Version 10.97.2 CFR1
    Affected: Version 10.97.2 CRF2
    Affected: Version 10.97.3
    Create a notification for this product.
    iconics genesis64 Affected: 10.97.2
    Affected: 10.97.2cfr1
    Affected: 10.97.2cfr2
    Affected: 10.97.3
        cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric genesis64 Affected: 10.97.2
    Affected: 10.97.2cfr1
    Affected: 10.97.2cfr2
    Affected: 10.97.3
        cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "10.97.2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr1"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.3"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "status": "affected",
                    "version": "10.97.2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr1"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.2cfr2"
                  },
                  {
                    "status": "affected",
                    "version": "10.97.3"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8300",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T18:50:37.535229Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T18:53:27.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 10.97.2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CFR1"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.2 CRF2"
                },
                {
                  "status": "affected",
                  "version": "Version 10.97.3"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-561",
                  "description": "CWE-561 Dead Code",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T07:52:13.107Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64 and ICONICS Suite",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-8300",
        "datePublished": "2024-11-28T22:18:28.358Z",
        "dateReserved": "2024-08-29T06:26:41.397Z",
        "dateUpdated": "2026-01-09T07:52:13.107Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-8299 (GCVE-0-2024-8299)

    Vulnerability from cvelistv5 – Published: 2024-11-28 22:16 – Updated: 2026-04-08 13:35
    VLAI
    Title
    Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-29 16:37 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8299",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-29T16:37:52.677330Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-29T16:40:42.486Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Asher Davila of Palo Alto Networks"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Malav Vyas of Palo Alto Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or to cause a denial of service (DoS) condition on the products."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:35:35.670Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-010_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU93891820"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-338-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-8299",
        "datePublished": "2024-11-28T22:16:31.396Z",
        "dateReserved": "2024-08-29T06:26:34.979Z",
        "dateUpdated": "2026-04-08T13:35:35.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-7587 (GCVE-0-2024-7587)

    Vulnerability from cvelistv5 – Published: 2024-10-22 22:19 – Updated: 2026-01-09 05:46
    VLAI
    Title
    Information Disclosure, Information Tampering and Denial of Service (DoS) Vulnerability in GENESIS64, ICONICS Suite, MC Works64, and GENESIS32
    Summary
    Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-23 14:15 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThanOrEqual": "10.97.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7587",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-23T14:15:49.960141Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T15:50:04.628Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.70.300.23 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.70.300.23 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32."
                }
              ],
              "value": "Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Information Disclosure, Information Tampering and Denial of Service (DoS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276 Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:46:11.126Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU95548104"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-296-01"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure, Information Tampering and Denial of Service (DoS) Vulnerability in GENESIS64, ICONICS Suite, MC Works64, and GENESIS32",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-7587",
        "datePublished": "2024-10-22T22:19:20.646Z",
        "dateReserved": "2024-08-07T08:06:04.877Z",
        "dateUpdated": "2026-01-09T05:46:11.126Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1574 (GCVE-0-2024-1574)

    Vulnerability from cvelistv5 – Published: 2024-07-04 09:02 – Updated: 2026-04-08 13:31
    VLAI
    Summary
    Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-05 14:44 UTC
    CWE
    • CWE-470 - Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions GENESIS32 Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS32 Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions BizViz Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation BizViz Affected: versions 9.7 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 10.97 , < 10.97.92 (custom)
        cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , ≤ * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "10.97.92",
                    "status": "affected",
                    "version": "10.97",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-05T14:44:19.238774Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T14:45:36.502Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.447Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-470",
                  "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:31:05.753Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1574",
        "datePublished": "2024-07-04T09:02:35.260Z",
        "dateReserved": "2024-02-16T01:30:45.960Z",
        "dateUpdated": "2026-04-08T13:31:05.753Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1573 (GCVE-0-2024-1573)

    Vulnerability from cvelistv5 – Published: 2024-07-04 08:59 – Updated: 2026-04-13 22:47
    VLAI
    Summary
    Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-05 14:46 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation AnalytiX Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Corporation MobileHMI Affected: versions 10.97.2 and prior
    Create a notification for this product.
    Mitsubishi Electric Iconics Digital Solutions IoTWorX Affected: version 10.95
    Create a notification for this product.
    Mitsubishi Electric Corporation IoTWorX Affected: version 10.95
    Create a notification for this product.
    Mitsubishi Electric Corporation MC Works64 Affected: all versions
    Create a notification for this product.
    iconics genesis64 Affected: 10.97 , < 10.97.92 (custom)
        cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mc_works64 Affected: 0 , ≤ * (custom)
        cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "10.97.92",
                    "status": "affected",
                    "version": "10.97",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1573",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-05T14:46:51.356597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T14:46:55.563Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.409Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.2 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "version 10.95"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "version 10.95"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
                }
              ],
              "value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-13T22:47:17.575Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1573",
        "datePublished": "2024-07-04T08:59:44.079Z",
        "dateReserved": "2024-02-16T01:30:41.285Z",
        "dateUpdated": "2026-04-13T22:47:17.575Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-1182 (GCVE-0-2024-1182)

    Vulnerability from cvelistv5 – Published: 2024-07-04 08:53 – Updated: 2026-04-08 13:28
    VLAI
    Summary
    Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-19 15:23 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:33:24.701Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU98894016/"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mc_works64",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1182",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-19T15:23:47.078975Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-19T15:25:49.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Malicious Code Execution"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-08T13:28:11.189Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU98894016/"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2024-1182",
        "datePublished": "2024-07-04T08:53:41.217Z",
        "dateReserved": "2024-02-02T00:20:48.886Z",
        "dateUpdated": "2026-04-08T13:28:11.189Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-26314 (GCVE-0-2024-26314)

    Vulnerability from cvelistv5 – Published: 2024-07-02 00:00 – Updated: 2025-03-21 20:37
    VLAI
    Summary
    Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 16:03 UTC
    CWE
    • n/a
    • CWE-269 - Improper Privilege Management
    Impacted products
    Vendor Product Version
    mitsubishielectric cpu_module_logging_configuration_tool Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_works2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric cw_configurator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric data_transfer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric ezsocket Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:ezsocket:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fr_configurator_sw3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fr_configurator2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    iconics genesis64 Affected: 0 , < * (custom)
        cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_designer3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_softgot1000 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gt_softgot2000 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_developer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_logviewer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric gx_works3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric melsoft_navigator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mi_configurator Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mi_configurator:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric fcsb1224 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:fcsb1224:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mr_configurator2 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mr_configurator2:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mrzjw3-mc2-utl Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mx_component Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric mx_opc_server_da\/ua Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:mx_opc_server_da\/ua:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric px_developer Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric rt_toolbox3 Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric rt_visualbox Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:rt_visualbox:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric c_controller_module_setting_and_monitoring_tool Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw0dnc-mneth-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccbd2-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccief-j Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-ccief-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-mnetg-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-mnetg-b:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnc-qsccf-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mitsubishielectric sw1dnd-emsdk-b Affected: 0 , < * (custom)
        cpe:2.3:a:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cpu_module_logging_configuration_tool",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cw_configurator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "data_transfer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:ezsocket:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ezsocket",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fr_configurator_sw3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fr_configurator2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "genesis64",
                "vendor": "iconics",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_designer3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_softgot1000",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gt_softgot2000",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_developer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_logviewer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gx_works3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "melsoft_navigator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mi_configurator:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mi_configurator",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:fcsb1224:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fcsb1224",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mr_configurator2:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mr_configurator2",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mrzjw3-mc2-utl",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mx_component",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mx_opc_server_da\\/ua",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "px_developer",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "rt_toolbox3",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:rt_visualbox:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "rt_visualbox",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "c_controller_module_setting_and_monitoring_tool",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw0dnc-mneth-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccbd2-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccief-j",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-ccief-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-mnetg-b:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-mnetg-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnc-qsccf-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sw1dnd-emsdk-b",
                "vendor": "mitsubishielectric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26314",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T16:03:22.624752Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-21T20:37:15.710Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.173Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jungo.com/windriver/versions/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-02T15:39:18.038Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://jungo.com/windriver/versions/"
            },
            {
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26314",
        "datePublished": "2024-07-02T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2025-03-21T20:37:15.710Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40264 (GCVE-0-2022-40264)

    Vulnerability from cvelistv5 – Published: 2022-12-13 23:32 – Updated: 2025-04-18 14:46
    VLAI
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-18 14:45 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:40.199Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-014_en.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU95858406/index.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://iconics.com/About/Security/CERT"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40264",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-18T14:45:23.695408Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-18T14:46:00.625Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "ICONICS and Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.96 to 10.97.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker."
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-13T23:32:57.049Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-014_en.pdf"
            },
            {
              "url": "https://jvn.jp/vu/JVNVU95858406/index.html"
            },
            {
              "url": "https://iconics.com/About/Security/CERT"
            },
            {
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-01"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-40264",
        "datePublished": "2022-12-13T23:32:57.049Z",
        "dateReserved": "2022-09-08T19:40:16.930Z",
        "dateUpdated": "2025-04-18T14:46:00.625Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-33319 (GCVE-0-2022-33319)

    Vulnerability from cvelistv5 – Published: 2022-07-20 16:58 – Updated: 2026-01-09 05:14
    VLAI
    Summary
    Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
                }
              ],
              "value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:14:32.690Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33319",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33319",
        "datePublished": "2022-07-20T16:58:49.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:14:32.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33318 (GCVE-0-2022-33318)

    Vulnerability from cvelistv5 – Published: 2022-07-20 16:57 – Updated: 2026-01-09 05:12
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.7 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:12:41.871Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33318",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33318",
        "datePublished": "2022-07-20T16:57:38.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:12:41.871Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33320 (GCVE-0-2022-33320)

    Vulnerability from cvelistv5 – Published: 2022-07-20 16:56 – Updated: 2026-01-09 05:16
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:16:27.798Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33320",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33320",
        "datePublished": "2022-07-20T16:56:24.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:16:27.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33315 (GCVE-0-2022-33315)

    Vulnerability from cvelistv5 – Published: 2022-07-20 16:55 – Updated: 2026-01-09 04:58
    VLAI
    Summary
    Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:01:20.500Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ],
              "value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T04:58:25.913Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33315",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Deserialization of Untrusted Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33315",
        "datePublished": "2022-07-20T16:55:13.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T04:58:25.913Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33317 (GCVE-0-2022-33317)

    Vulnerability from cvelistv5 – Published: 2022-07-20 16:53 – Updated: 2026-01-09 05:09
    VLAI
    Summary
    Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:09:21.143Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 10.97 to 10.97.1"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 4.04E and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
                }
              ],
              "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T05:09:15.556Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "ID": "CVE-2022-33317",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
                              },
                              {
                                "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Inclusion of Functionality from Untrusted Control Sphere"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU96480474/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU96480474/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2022-33317",
        "datePublished": "2022-07-20T16:53:59.000Z",
        "dateReserved": "2022-06-14T00:00:00.000Z",
        "dateUpdated": "2026-01-09T05:09:15.556Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }