    CVE-2026-131813 (GCVE-0-2026-131813)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:45
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP UpdateFirmware requests. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-29487.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:35 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    References
    Impacted products
    Date Public
    2026-11-19 15:54
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131813",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:35:04.842933Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:45:58.080Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:56:07.285Z",
          "datePublic": "2026-11-19T15:54:03.686Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP UpdateFirmware requests. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-29487."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:44.280Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1038",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1038/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Autocrypt(Hoyong Jin, Jaewoo Jeong, Chanhyeok Jung, Minsoo Son, Kisang Choi)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131813",
        "datePublished": "2026-11-19T16:08:44.280Z",
        "dateReserved": "2026-11-17T22:56:07.256Z",
        "dateUpdated": "2026-11-19T16:45:58.080Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131812 (GCVE-0-2026-131812)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131812",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:59.218747Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:02.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:56:03.583Z",
          "datePublic": "2026-11-18T20:03:26.707Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:23.127Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1034",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1034/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Hyeongseok Lee (@fluorite_pwn), Yunje Shin (@YunjeShin), Chaeeul Hyun (@yskm_Gunter), Ingyu Yang (@Mafty5275), Hoseok Kang (@clay419), Seungyeon Park (@vvsy46), and Wonjun Choi (@won6_choi) of BoB::Takedown"
          },
          "title": "United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131812",
        "datePublished": "2026-11-19T16:08:23.127Z",
        "dateReserved": "2026-11-17T22:56:03.551Z",
        "dateUpdated": "2026-11-19T16:47:02.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131811 (GCVE-0-2026-131811)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the OCPP backend settings interface. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29056.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    References
    Impacted products
    Date Public
    2026-11-18 20:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131811",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:49.875124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:31.879Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.027-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:59.356Z",
          "datePublic": "2026-11-18T20:02:58.149Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the OCPP backend settings interface. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29056."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:13.101Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1032",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1032/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Taejin Kim(@_tae3_), Junsu Yeo(@junactually), Sunmin Park(@sunminpark4503), Sungmin Son(@_ssm98), Hoseok Lee of SKShieldus(@EQSTLab)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131811",
        "datePublished": "2026-11-19T16:08:13.101Z",
        "dateReserved": "2026-11-17T22:55:59.322Z",
        "dateUpdated": "2026-11-19T16:47:31.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131810 (GCVE-0-2026-131810)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper verification of firmware integrity prior to installation. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28957.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:34 UTC
    CWE
    • CWE-494 - Download of Code Without Integrity Check
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131810",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:34:25.495548Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:48.515Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.027-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:55.405Z",
          "datePublic": "2026-11-18T20:03:34.299Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper verification of firmware integrity prior to installation. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28957."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494: Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:28.078Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1035",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1035/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Taejin Kim(@_tae3_), Junsu Yeo(@junactually), Sunmin Park(@sunminpark4503), Sungmin Son(@_ssm98), Hoseok Lee of SKShieldus(@EQSTLab)"
          },
          "title": "United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131810",
        "datePublished": "2026-11-19T16:08:28.078Z",
        "dateReserved": "2026-11-17T22:55:55.377Z",
        "dateUpdated": "2026-11-19T16:46:48.515Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131809 (GCVE-0-2026-131809)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP backend configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29063.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:35 UTC
    CWE
    • CWE-425 - Direct Request ('Forced Browsing')
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131809",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:35:22.606766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:16.758Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:51.290Z",
          "datePublic": "2026-11-18T20:03:50.976Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP backend configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29063."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-425",
                  "description": "CWE-425: Direct Request (\u0027Forced Browsing\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:38.420Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1037",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1037/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Cyrill Bannwart, Emanuele Barbeno, Yves Bieri, Lukasz D., Urs Mueller of Compass Security"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131809",
        "datePublished": "2026-11-19T16:08:38.420Z",
        "dateReserved": "2026-11-17T22:55:51.258Z",
        "dateUpdated": "2026-11-19T16:46:16.758Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131808 (GCVE-0-2026-131808)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability. This vulnerability allows network-adjacent attackers to modify Wi-Fi configuration on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of Wi-Fi configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29068.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:34 UTC
    CWE
    • CWE-425 - Direct Request ('Forced Browsing')
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131808",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:34:50.997558Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:33.503Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:47.949Z",
          "datePublic": "2026-11-18T20:03:42.168Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability. This vulnerability allows network-adjacent attackers to modify Wi-Fi configuration on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of Wi-Fi configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29068."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-425",
                  "description": "CWE-425: Direct Request (\u0027Forced Browsing\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:33.912Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1036",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1036/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Bongeun Koo (@kiddo_pwn) and Evangelos Daravigkas (@freddo_1337) of Team DDOS"
          },
          "title": "United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131808",
        "datePublished": "2026-11-19T16:08:33.912Z",
        "dateReserved": "2026-11-17T22:55:47.919Z",
        "dateUpdated": "2026-11-19T16:46:33.503Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131807 (GCVE-0-2026-131807)

    Vulnerability from nvd – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. When parsing GetConfiguration requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28968.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131807",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:34.046748Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:17.429Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:44.706Z",
          "datePublic": "2026-11-18T20:03:17.512Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP messages. When parsing GetConfiguration requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28968."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:17.793Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1033",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1033/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "PetoWorks (@petoworks)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131807",
        "datePublished": "2026-11-19T16:08:17.793Z",
        "dateReserved": "2026-11-17T22:55:44.653Z",
        "dateUpdated": "2026-11-19T16:47:17.429Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131813 (GCVE-0-2026-131813)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:45
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP UpdateFirmware requests. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-29487.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:35 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    References
    Impacted products
    Date Public
    2026-11-19 15:54
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131813",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:35:04.842933Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:45:58.080Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:56:07.285Z",
          "datePublic": "2026-11-19T15:54:03.686Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP UpdateFirmware requests. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-29487."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:44.280Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1038",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1038/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Autocrypt(Hoyong Jin, Jaewoo Jeong, Chanhyeok Jung, Minsoo Son, Kisang Choi)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP UpdateFirmware Out-Of-Bounds Write Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131813",
        "datePublished": "2026-11-19T16:08:44.280Z",
        "dateReserved": "2026-11-17T22:56:07.256Z",
        "dateUpdated": "2026-11-19T16:45:58.080Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131809 (GCVE-0-2026-131809)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP backend configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29063.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:35 UTC
    CWE
    • CWE-425 - Direct Request ('Forced Browsing')
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131809",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:35:22.606766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:16.758Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:51.290Z",
          "datePublic": "2026-11-18T20:03:50.976Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP backend configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29063."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-425",
                  "description": "CWE-425: Direct Request (\u0027Forced Browsing\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:38.420Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1037",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1037/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Cyrill Bannwart, Emanuele Barbeno, Yves Bieri, Lukasz D., Urs Mueller of Compass Security"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131809",
        "datePublished": "2026-11-19T16:08:38.420Z",
        "dateReserved": "2026-11-17T22:55:51.258Z",
        "dateUpdated": "2026-11-19T16:46:16.758Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131808 (GCVE-0-2026-131808)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability. This vulnerability allows network-adjacent attackers to modify Wi-Fi configuration on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of Wi-Fi configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29068.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:34 UTC
    CWE
    • CWE-425 - Direct Request ('Forced Browsing')
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131808",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:34:50.997558Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:33.503Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:47.949Z",
          "datePublic": "2026-11-18T20:03:42.168Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability. This vulnerability allows network-adjacent attackers to modify Wi-Fi configuration on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of Wi-Fi configuration requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29068."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-425",
                  "description": "CWE-425: Direct Request (\u0027Forced Browsing\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:33.912Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1036",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1036/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Bongeun Koo (@kiddo_pwn) and Evangelos Daravigkas (@freddo_1337) of Team DDOS"
          },
          "title": "United Chargers Grizzl-E Smart 40A Wi-Fi Configuration Server Missing Authentication Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131808",
        "datePublished": "2026-11-19T16:08:33.912Z",
        "dateReserved": "2026-11-17T22:55:47.919Z",
        "dateUpdated": "2026-11-19T16:46:33.503Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131810 (GCVE-0-2026-131810)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:46
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper verification of firmware integrity prior to installation. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28957.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:34 UTC
    CWE
    • CWE-494 - Download of Code Without Integrity Check
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131810",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:34:25.495548Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:46:48.515Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.027-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:55.405Z",
          "datePublic": "2026-11-18T20:03:34.299Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper verification of firmware integrity prior to installation. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28957."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494: Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:28.078Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1035",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1035/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Taejin Kim(@_tae3_), Junsu Yeo(@junactually), Sunmin Park(@sunminpark4503), Sungmin Son(@_ssm98), Hoseok Lee of SKShieldus(@EQSTLab)"
          },
          "title": "United Chargers Grizzl-E Smart 40A Download of Code Without Integrity Check Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131810",
        "datePublished": "2026-11-19T16:08:28.078Z",
        "dateReserved": "2026-11-17T22:55:55.377Z",
        "dateUpdated": "2026-11-19T16:46:48.515Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131812 (GCVE-0-2026-131812)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131812",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:59.218747Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:02.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:56:03.583Z",
          "datePublic": "2026-11-18T20:03:26.707Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:23.127Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1034",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1034/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Hyeongseok Lee (@fluorite_pwn), Yunje Shin (@YunjeShin), Chaeeul Hyun (@yskm_Gunter), Ingyu Yang (@Mafty5275), Hoseok Kang (@clay419), Seungyeon Park (@vvsy46), and Wonjun Choi (@won6_choi) of BoB::Takedown"
          },
          "title": "United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131812",
        "datePublished": "2026-11-19T16:08:23.127Z",
        "dateReserved": "2026-11-17T22:56:03.551Z",
        "dateUpdated": "2026-11-19T16:47:02.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131807 (GCVE-0-2026-131807)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. When parsing GetConfiguration requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28968.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Date Public
    2026-11-18 20:03
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131807",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:34.046748Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:17.429Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.029-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:44.706Z",
          "datePublic": "2026-11-18T20:03:17.512Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP messages. When parsing GetConfiguration requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28968."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:17.793Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1033",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1033/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "PetoWorks (@petoworks)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP GetConfiguration Stack-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131807",
        "datePublished": "2026-11-19T16:08:17.793Z",
        "dateReserved": "2026-11-17T22:55:44.653Z",
        "dateUpdated": "2026-11-19T16:47:17.429Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-131811 (GCVE-0-2026-131811)

    Vulnerability from cvelistv5 – Published: 2026-11-19 16:08 – Updated: 2026-11-19 16:47
    VLAI
    Title
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability
    Summary
    United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the OCPP backend settings interface. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29056.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-19 16:33 UTC
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    References
    Impacted products
    Date Public
    2026-11-18 20:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-131811",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-19T16:33:49.875124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-19T16:47:31.879Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Grizzl-E Smart 40A",
              "vendor": "United Chargers",
              "versions": [
                {
                  "status": "affected",
                  "version": "GWM-07.027-03"
                }
              ]
            }
          ],
          "dateAssigned": "2026-11-17T22:55:59.356Z",
          "datePublic": "2026-11-18T20:02:58.149Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the OCPP backend settings interface. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29056."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-19T16:08:13.101Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-1032",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-1032/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Taejin Kim(@_tae3_), Junsu Yeo(@junactually), Sunmin Park(@sunminpark4503), Sungmin Son(@_ssm98), Hoseok Lee of SKShieldus(@EQSTLab)"
          },
          "title": "United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-131811",
        "datePublished": "2026-11-19T16:08:13.101Z",
        "dateReserved": "2026-11-17T22:55:59.322Z",
        "dateUpdated": "2026-11-19T16:47:31.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }