Search

Find a vulnerability

Search criteria

    359 vulnerabilities by ABB

    CVE-2026-15953 (GCVE-0-2026-15953)

    Vulnerability from nvd – Published: 2026-09-28 13:17 – Updated: 2026-09-28 16:32
    VLAI
    Title
    Path Traversal During Project Archive Import
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Protection and control IED manager (PCM600). This issue affects Protection and control IED manager (PCM600): through 2.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-28 15:48 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15953",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-28T15:48:49.199702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-28T16:32:28.788Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Protection and control IED manager (PCM600)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Protection and control IED manager (PCM600).\u003cp\u003eThis issue affects Protection and control IED manager (PCM600): through 2.14.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Protection and control IED manager (PCM600).\n\nThis issue affects Protection and control IED manager (PCM600): through 2.14."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-28T13:17:46.752Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA003179\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal During Project Archive Import",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-15953",
        "datePublished": "2026-09-28T13:17:46.752Z",
        "dateReserved": "2026-07-16T13:14:19.501Z",
        "dateUpdated": "2026-09-28T16:32:28.788Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-15952 (GCVE-0-2026-15952)

    Vulnerability from nvd – Published: 2026-09-28 13:10 – Updated: 2026-09-28 17:59
    VLAI
    Title
    Improper Permission Assignment in Scheduler Service
    Summary
    Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600). This issue affects Protection and control IED manager (PCM600): through 2.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-28 17:59 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15952",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-28T17:59:16.963827Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-28T17:59:28.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Protection and control IED manager (PCM600)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).\u003cp\u003eThis issue affects Protection and control IED manager (PCM600): through 2.14.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).\n\nThis issue affects Protection and control IED manager (PCM600): through 2.14."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-28T13:10:28.374Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA003170\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper Permission Assignment in Scheduler Service",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-15952",
        "datePublished": "2026-09-28T13:10:28.374Z",
        "dateReserved": "2026-07-16T13:14:17.355Z",
        "dateUpdated": "2026-09-28T17:59:28.712Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19438 (GCVE-0-2026-19438)

    Vulnerability from nvd – Published: 2026-09-23 05:05 – Updated: 2026-09-23 14:11
    VLAI
    Title
    Mint Workbench I Path traversal Vulnerability
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Mint Workbench I. This issue affects Mint Workbench I: through 5876.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 14:09 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Vendor Product Version
    ABB Mint Workbench I Affected: 0 , ≤ 5876 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19438",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T14:09:43.306887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T14:11:12.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Mint Workbench I",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "5876",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Mint Workbench I.\u003cp\u003eThis issue affects Mint Workbench I: through 5876.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Mint Workbench I.\n\nThis issue affects Mint Workbench I: through 5876."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-23T05:05:16.249Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108473A3188\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Mint Workbench I Path traversal Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-19438",
        "datePublished": "2026-09-23T05:05:16.249Z",
        "dateReserved": "2026-08-10T12:59:29.728Z",
        "dateUpdated": "2026-09-23T14:11:12.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-5778 (GCVE-0-2023-5778)

    Vulnerability from nvd – Published: 2026-09-18 13:19 – Updated: 2026-09-18 14:31
    VLAI
    Title
    Missing Length Check
    Summary
    Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900. This issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-18 14:12 UTC
    CWE
    • CWE-130 - Improper handling of length parameter inconsistency
    Impacted products
    Vendor Product Version
    ABB Freelance Controller DCP Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC700 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC800 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC900 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-18T14:12:56.535431Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-18T14:31:45.340Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller DCP",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC700",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC800",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC900",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900.\u003cp\u003eThis issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1.\u003c/p\u003e"
                }
              ],
              "value": "Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900.\n\nThis issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/AU:Y/R:U/V:C/RE:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "HIGH"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-130",
                  "description": "CWE-130 Improper handling of length parameter inconsistency",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-18T13:19:47.850Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA010706\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing Length Check",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2023-5778",
        "datePublished": "2026-09-18T13:19:47.850Z",
        "dateReserved": "2023-10-26T01:57:08.369Z",
        "dateUpdated": "2026-09-18T14:31:45.340Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12705 (GCVE-0-2026-12705)

    Vulnerability from nvd – Published: 2026-07-17 14:30 – Updated: 2026-07-17 15:25
    VLAI
    Title
    Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool
    Summary
    Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE). This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-07-17 15:25 UTC
    CWE
    • CWE-353 - Missing support for integrity check
    Impacted products
    Vendor Product Version
    ABB KNX Update Tool (ABB) Affected: 0 , ≤ 2.0.175 (custom)
    Create a notification for this product.
    ABB KNX Update Tool (BJE) Affected: 0 , ≤ 2.0.175 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12705",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-17T15:25:25.663244Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-17T15:25:38.129Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "KNX Update Tool (ABB)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.175",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "KNX Update Tool (BJE)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.175",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\u003cp\u003eThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.\u003c/p\u003e"
                }
              ],
              "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\n\nThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-353",
                  "description": "CWE-353 Missing support for integrity check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-17T14:30:48.974Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A9270\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-12705",
        "datePublished": "2026-07-17T14:30:48.974Z",
        "dateReserved": "2026-06-19T10:24:46.696Z",
        "dateUpdated": "2026-07-17T15:25:38.129Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13162 (GCVE-0-2025-13162)

    Vulnerability from nvd – Published: 2026-06-23 16:12 – Updated: 2026-06-23 17:21
    VLAI
    Title
    Advant Master Online Builder DLL vulnerability
    Summary
    Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-23 17:20 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    Impacted products
    Vendor Product Version
    ABB Control Builder A Affected: 0 , ≤ 1.4/4 (custom)
    Create a notification for this product.
    ABB 800xA for Advant Master Affected: 0 , ≤ 6.0.3-1 (custom)
    Affected: 0 , ≤ 6.1.1-1 (custom)
    Affected: 6.1.1-3 (custom)
    Affected: 6.2.0-1 (custom)
    Unaffected: 6.1.1-2 (custom)
    Unaffected: 6.1.1-4 (custom)
    Unaffected: 6.2.0-2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13162",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-23T17:20:43.036189Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-23T17:21:02.465Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control Builder A",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.4/4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "800xA for Advant Master",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.0.3-1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.1.1-3",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.2.0-1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.1.1-2",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.1.1-4",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.2.0-2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.\u003cp\u003eThis issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.\u003c/p\u003e"
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.\n\nThis issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 4.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-23T16:19:27.088Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020047\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Advant Master Online Builder DLL vulnerability",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13162",
        "datePublished": "2026-06-23T16:12:54.330Z",
        "dateReserved": "2025-11-14T03:20:45.405Z",
        "dateUpdated": "2026-06-23T17:21:02.465Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-7064 (GCVE-0-2025-7064)

    Vulnerability from nvd – Published: 2026-06-11 09:07 – Updated: 2026-06-11 12:43
    VLAI
    Title
    Freelance Security Lock – Access to Windows OS
    Summary
    Authentication bypass by primary weakness vulnerability in ABB Freelance. This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-11 12:43 UTC
    CWE
    • CWE-305 - Authentication bypass by primary weakness
    Impacted products
    Vendor Product Version
    ABB Freelance Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Affected: 2019 SP1 FP1 (custom)
    Affected: 2024 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7064",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-11T12:43:43.075897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-11T12:43:52.186Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Freelance",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\u003cp\u003eThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\n\nThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:H/SA:L/E:P/AU:N/R:U/V:D/RE:L/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-305",
                  "description": "CWE-305 Authentication bypass by primary weakness",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-11T09:07:30.912Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Freelance Security Lock \u2013 Access to Windows OS",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7064",
        "datePublished": "2026-06-11T09:07:30.912Z",
        "dateReserved": "2025-07-04T09:09:57.969Z",
        "dateUpdated": "2026-06-11T12:43:52.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14774 (GCVE-0-2025-14774)

    Vulnerability from nvd – Published: 2026-06-03 09:48 – Updated: 2026-06-03 12:16
    VLAI
    Title
    Communication analysis between the Card Reader and TP2CardReaderService daemon
    Summary
    Incorrect Authorization vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:14 UTC
    CWE
    • CWE-863 - Incorrect Authorization
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:14:15.995844Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:16:24.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:48:00.681Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Communication analysis between the Card Reader and TP2CardReaderService daemon",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14774",
        "datePublished": "2026-06-03T09:48:00.681Z",
        "dateReserved": "2025-12-16T03:47:14.477Z",
        "dateUpdated": "2026-06-03T12:16:24.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14773 (GCVE-0-2025-14773)

    Vulnerability from nvd – Published: 2026-06-03 09:40 – Updated: 2026-06-03 12:24
    VLAI
    Title
    Stored Cross-Site Scripting in ABB T-MAC Plus web application
    Summary
    Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:23 UTC
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14773",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:23:55.931603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:24:07.651Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:A/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:40:00.432Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stored Cross-Site Scripting in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14773",
        "datePublished": "2026-06-03T09:40:00.432Z",
        "dateReserved": "2025-12-16T03:47:13.941Z",
        "dateUpdated": "2026-06-03T12:24:07.651Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14772 (GCVE-0-2025-14772)

    Vulnerability from nvd – Published: 2026-06-03 09:25 – Updated: 2026-06-03 12:49
    VLAI
    Title
    Broken Access Control in ABB T-MAC Plus web application
    Summary
    Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:47 UTC
    CWE
    • CWE-639 - Authorization bypass through User-Controlled key
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14772",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:47:39.611706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:49:14.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization bypass through User-Controlled key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:25:56.511Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Broken Access Control in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14772",
        "datePublished": "2026-06-03T09:25:56.511Z",
        "dateReserved": "2025-12-16T03:47:13.359Z",
        "dateUpdated": "2026-06-03T12:49:14.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14771 (GCVE-0-2025-14771)

    Vulnerability from nvd – Published: 2026-06-03 09:16 – Updated: 2026-06-03 13:02
    VLAI
    Title
    File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC plus Server - Default IIS Web Site
    Summary
    Files or directories accessible to external parties vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:56 UTC
    CWE
    • CWE-552 - Files or directories accessible to external parties
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14771",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:56:59.726942Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T13:02:53.833Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or directories accessible to external parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:16:02.527Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC  plus Server - Default IIS Web Site",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14771",
        "datePublished": "2026-06-03T09:16:02.527Z",
        "dateReserved": "2025-12-16T03:47:13.262Z",
        "dateUpdated": "2026-06-03T13:02:53.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-3756 (GCVE-0-2025-3756)

    Vulnerability from nvd – Published: 2026-04-13 17:11 – Updated: 2026-04-13 18:03
    VLAI
    Title
    Denial of Service Vulnerabilities in System 800xA, Symphony® Plus IEC 61850
    Summary
    A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.  The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.     This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-13 18:02 UTC
    CWE
    • CWE-1284 - Improper validation of specified quantity in input
    Impacted products
    Vendor Product Version
    ABB AC800M (System 800xA) Affected: 6.0.0x , ≤ 6.0.0303.0 (custom)
    Affected: 6.1.0x , ≤ 6.1.0031.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1004.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1202.0 (custom)
    Affected: 6.2.0x , ≤ 6.2.0006.0 (custom)
    Create a notification for this product.
    ABB Symphony Plus SD Series Affected: A_0 (custom)
    Affected: A_1 (custom)
    Affected: A_2.003 (custom)
    Affected: A_3.005 (custom)
    Affected: A_4.001 (custom)
    Affected: B_0.005 (custom)
    Create a notification for this product.
    ABB Symphony Plus MR (Melody Rack) Affected: 3.10 , ≤ 3.52 (custom)
    Create a notification for this product.
    ABB S+ Operations Affected: 2.1 (custom)
    Affected: 2.2 (custom)
    Affected: 2.3 (custom)
    Affected: 3.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3756",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-13T18:02:41.810841Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-13T18:03:41.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI868"
              ],
              "product": "AC800M (System 800xA)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.0.0303.0",
                  "status": "affected",
                  "version": "6.0.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.0031.0",
                  "status": "affected",
                  "version": "6.1.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1004.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1202.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.2.0006.0",
                  "status": "affected",
                  "version": "6.2.0x",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI850"
              ],
              "product": "Symphony Plus SD Series",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "A_0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_2.003",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_3.005",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_4.001",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "B_0.005",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "PM 877"
              ],
              "product": "Symphony Plus MR (Melody Rack)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "3.52",
                  "status": "affected",
                  "version": "3.10",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "S+ Operations",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.3",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "3.3",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB thanks Hitachi Energy for sharing the information affecting a commonly used software component."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003eA vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\u003c/div\u003e\u003cdiv\u003e\u0026nbsp; \u0026nbsp;\u003c/div\u003e\u003c/div\u003e\u003cp\u003eThis issue affects AC800M (System 800xA):\u0026nbsp;\u003cspan\u003efrom 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u00a0\n\n\n\n\nThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\n\n\u00a0 \u00a0\n\n\n\nThis issue affects AC800M (System 800xA):\u00a0from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1284",
                  "description": "CWE-1284 Improper validation of specified quantity in input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-13T17:11:08.412Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Denial of Service Vulnerabilities in System  800xA, Symphony\u00ae Plus IEC 61850",
          "x_generator": {
            "engine": "Vulnogram 1.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-3756",
        "datePublished": "2026-04-13T17:11:08.412Z",
        "dateReserved": "2025-04-17T10:42:33.414Z",
        "dateUpdated": "2026-04-13T18:03:41.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13779 (GCVE-0-2025-13779)

    Vulnerability from nvd – Published: 2026-03-13 13:11 – Updated: 2026-03-13 14:11
    VLAI
    Title
    Configuration Data Spill
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 14:11 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T14:11:49.624286Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T14:11:57.527Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:11:11.547Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Configuration Data Spill",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13779",
        "datePublished": "2026-03-13T13:11:11.547Z",
        "dateReserved": "2025-11-28T14:22:33.792Z",
        "dateUpdated": "2026-03-13T14:11:57.527Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13778 (GCVE-0-2025-13778)

    Vulnerability from nvd – Published: 2026-03-13 13:08 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Device Reboot Control
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 13:35 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:12.366891Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:18.364Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:12:03.419Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Device Reboot Control",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13778",
        "datePublished": "2026-03-13T13:08:40.380Z",
        "dateReserved": "2025-11-28T14:22:33.054Z",
        "dateUpdated": "2026-03-13T13:35:18.364Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13777 (GCVE-0-2025-13777)

    Vulnerability from nvd – Published: 2026-03-13 13:05 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Authentication Bypass due to Improper Session Validation
    Summary
    Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 13:35 UTC
    CWE
    • CWE-294 - Authentication bypass by capture-replay
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13777",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:31.062507Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:36.115Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication bypass by capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:05:26.329Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication Bypass due to Improper Session Validation",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13777",
        "datePublished": "2026-03-13T13:05:26.329Z",
        "dateReserved": "2025-11-28T14:22:32.497Z",
        "dateUpdated": "2026-03-13T13:35:36.115Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-15953 (GCVE-0-2026-15953)

    Vulnerability from cvelistv5 – Published: 2026-09-28 13:17 – Updated: 2026-09-28 16:32
    VLAI
    Title
    Path Traversal During Project Archive Import
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Protection and control IED manager (PCM600). This issue affects Protection and control IED manager (PCM600): through 2.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-28 15:48 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15953",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-28T15:48:49.199702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-28T16:32:28.788Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Protection and control IED manager (PCM600)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Protection and control IED manager (PCM600).\u003cp\u003eThis issue affects Protection and control IED manager (PCM600): through 2.14.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Protection and control IED manager (PCM600).\n\nThis issue affects Protection and control IED manager (PCM600): through 2.14."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-28T13:17:46.752Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA003179\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal During Project Archive Import",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-15953",
        "datePublished": "2026-09-28T13:17:46.752Z",
        "dateReserved": "2026-07-16T13:14:19.501Z",
        "dateUpdated": "2026-09-28T16:32:28.788Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-15952 (GCVE-0-2026-15952)

    Vulnerability from cvelistv5 – Published: 2026-09-28 13:10 – Updated: 2026-09-28 17:59
    VLAI
    Title
    Improper Permission Assignment in Scheduler Service
    Summary
    Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600). This issue affects Protection and control IED manager (PCM600): through 2.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-28 17:59 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15952",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-28T17:59:16.963827Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-28T17:59:28.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Protection and control IED manager (PCM600)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).\u003cp\u003eThis issue affects Protection and control IED manager (PCM600): through 2.14.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).\n\nThis issue affects Protection and control IED manager (PCM600): through 2.14."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-28T13:10:28.374Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA003170\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper Permission Assignment in Scheduler Service",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-15952",
        "datePublished": "2026-09-28T13:10:28.374Z",
        "dateReserved": "2026-07-16T13:14:17.355Z",
        "dateUpdated": "2026-09-28T17:59:28.712Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19438 (GCVE-0-2026-19438)

    Vulnerability from cvelistv5 – Published: 2026-09-23 05:05 – Updated: 2026-09-23 14:11
    VLAI
    Title
    Mint Workbench I Path traversal Vulnerability
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Mint Workbench I. This issue affects Mint Workbench I: through 5876.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 14:09 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Impacted products
    Vendor Product Version
    ABB Mint Workbench I Affected: 0 , ≤ 5876 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19438",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T14:09:43.306887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T14:11:12.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Mint Workbench I",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "5876",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Mint Workbench I.\u003cp\u003eThis issue affects Mint Workbench I: through 5876.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB Mint Workbench I.\n\nThis issue affects Mint Workbench I: through 5876."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-23T05:05:16.249Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108473A3188\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Mint Workbench I Path traversal Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-19438",
        "datePublished": "2026-09-23T05:05:16.249Z",
        "dateReserved": "2026-08-10T12:59:29.728Z",
        "dateUpdated": "2026-09-23T14:11:12.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-5778 (GCVE-0-2023-5778)

    Vulnerability from cvelistv5 – Published: 2026-09-18 13:19 – Updated: 2026-09-18 14:31
    VLAI
    Title
    Missing Length Check
    Summary
    Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900. This issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-18 14:12 UTC
    CWE
    • CWE-130 - Improper handling of length parameter inconsistency
    Impacted products
    Vendor Product Version
    ABB Freelance Controller DCP Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC700 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC800 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    ABB Freelance Controller AC900 Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Unaffected: 2019 SP1 FP1 (custom)
    Unaffected: 2024 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-18T14:12:56.535431Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-18T14:31:45.340Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller DCP",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC700",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC800",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Freelance Controller AC900",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900.\u003cp\u003eThis issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1.\u003c/p\u003e"
                }
              ],
              "value": "Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900.\n\nThis issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/AU:Y/R:U/V:C/RE:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "HIGH"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-130",
                  "description": "CWE-130 Improper handling of length parameter inconsistency",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-18T13:19:47.850Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA010706\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing Length Check",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2023-5778",
        "datePublished": "2026-09-18T13:19:47.850Z",
        "dateReserved": "2023-10-26T01:57:08.369Z",
        "dateUpdated": "2026-09-18T14:31:45.340Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12705 (GCVE-0-2026-12705)

    Vulnerability from cvelistv5 – Published: 2026-07-17 14:30 – Updated: 2026-07-17 15:25
    VLAI
    Title
    Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool
    Summary
    Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE). This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-07-17 15:25 UTC
    CWE
    • CWE-353 - Missing support for integrity check
    Impacted products
    Vendor Product Version
    ABB KNX Update Tool (ABB) Affected: 0 , ≤ 2.0.175 (custom)
    Create a notification for this product.
    ABB KNX Update Tool (BJE) Affected: 0 , ≤ 2.0.175 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12705",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-17T15:25:25.663244Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-17T15:25:38.129Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "KNX Update Tool (ABB)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.175",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "KNX Update Tool (BJE)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.175",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\u003cp\u003eThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.\u003c/p\u003e"
                }
              ],
              "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\n\nThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-353",
                  "description": "CWE-353 Missing support for integrity check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-17T14:30:48.974Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A9270\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-12705",
        "datePublished": "2026-07-17T14:30:48.974Z",
        "dateReserved": "2026-06-19T10:24:46.696Z",
        "dateUpdated": "2026-07-17T15:25:38.129Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13162 (GCVE-0-2025-13162)

    Vulnerability from cvelistv5 – Published: 2026-06-23 16:12 – Updated: 2026-06-23 17:21
    VLAI
    Title
    Advant Master Online Builder DLL vulnerability
    Summary
    Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-23 17:20 UTC
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    Impacted products
    Vendor Product Version
    ABB Control Builder A Affected: 0 , ≤ 1.4/4 (custom)
    Create a notification for this product.
    ABB 800xA for Advant Master Affected: 0 , ≤ 6.0.3-1 (custom)
    Affected: 0 , ≤ 6.1.1-1 (custom)
    Affected: 6.1.1-3 (custom)
    Affected: 6.2.0-1 (custom)
    Unaffected: 6.1.1-2 (custom)
    Unaffected: 6.1.1-4 (custom)
    Unaffected: 6.2.0-2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13162",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-23T17:20:43.036189Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-23T17:21:02.465Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control Builder A",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.4/4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "800xA for Advant Master",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.0.3-1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.1.1-3",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.2.0-1",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.1.1-2",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.1.1-4",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.2.0-2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.\u003cp\u003eThis issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.\u003c/p\u003e"
                }
              ],
              "value": "Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.\n\nThis issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 4.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-23T16:19:27.088Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020047\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Advant Master Online Builder DLL vulnerability",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13162",
        "datePublished": "2026-06-23T16:12:54.330Z",
        "dateReserved": "2025-11-14T03:20:45.405Z",
        "dateUpdated": "2026-06-23T17:21:02.465Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-7064 (GCVE-0-2025-7064)

    Vulnerability from cvelistv5 – Published: 2026-06-11 09:07 – Updated: 2026-06-11 12:43
    VLAI
    Title
    Freelance Security Lock – Access to Windows OS
    Summary
    Authentication bypass by primary weakness vulnerability in ABB Freelance. This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-11 12:43 UTC
    CWE
    • CWE-305 - Authentication bypass by primary weakness
    Impacted products
    Vendor Product Version
    ABB Freelance Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Affected: 2019 SP1 FP1 (custom)
    Affected: 2024 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7064",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-11T12:43:43.075897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-11T12:43:52.186Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Freelance",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\u003cp\u003eThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\n\nThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:H/SA:L/E:P/AU:N/R:U/V:D/RE:L/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-305",
                  "description": "CWE-305 Authentication bypass by primary weakness",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-11T09:07:30.912Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Freelance Security Lock \u2013 Access to Windows OS",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7064",
        "datePublished": "2026-06-11T09:07:30.912Z",
        "dateReserved": "2025-07-04T09:09:57.969Z",
        "dateUpdated": "2026-06-11T12:43:52.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14774 (GCVE-0-2025-14774)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:48 – Updated: 2026-06-03 12:16
    VLAI
    Title
    Communication analysis between the Card Reader and TP2CardReaderService daemon
    Summary
    Incorrect Authorization vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:14 UTC
    CWE
    • CWE-863 - Incorrect Authorization
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:14:15.995844Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:16:24.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:48:00.681Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Communication analysis between the Card Reader and TP2CardReaderService daemon",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14774",
        "datePublished": "2026-06-03T09:48:00.681Z",
        "dateReserved": "2025-12-16T03:47:14.477Z",
        "dateUpdated": "2026-06-03T12:16:24.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14773 (GCVE-0-2025-14773)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:40 – Updated: 2026-06-03 12:24
    VLAI
    Title
    Stored Cross-Site Scripting in ABB T-MAC Plus web application
    Summary
    Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:23 UTC
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14773",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:23:55.931603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:24:07.651Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:A/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:40:00.432Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stored Cross-Site Scripting in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14773",
        "datePublished": "2026-06-03T09:40:00.432Z",
        "dateReserved": "2025-12-16T03:47:13.941Z",
        "dateUpdated": "2026-06-03T12:24:07.651Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14772 (GCVE-0-2025-14772)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:25 – Updated: 2026-06-03 12:49
    VLAI
    Title
    Broken Access Control in ABB T-MAC Plus web application
    Summary
    Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:47 UTC
    CWE
    • CWE-639 - Authorization bypass through User-Controlled key
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14772",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:47:39.611706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:49:14.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization bypass through User-Controlled key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:25:56.511Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Broken Access Control in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14772",
        "datePublished": "2026-06-03T09:25:56.511Z",
        "dateReserved": "2025-12-16T03:47:13.359Z",
        "dateUpdated": "2026-06-03T12:49:14.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14771 (GCVE-0-2025-14771)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:16 – Updated: 2026-06-03 13:02
    VLAI
    Title
    File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC plus Server - Default IIS Web Site
    Summary
    Files or directories accessible to external parties vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-03 12:56 UTC
    CWE
    • CWE-552 - Files or directories accessible to external parties
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14771",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:56:59.726942Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T13:02:53.833Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or directories accessible to external parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:16:02.527Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC  plus Server - Default IIS Web Site",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14771",
        "datePublished": "2026-06-03T09:16:02.527Z",
        "dateReserved": "2025-12-16T03:47:13.262Z",
        "dateUpdated": "2026-06-03T13:02:53.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-3756 (GCVE-0-2025-3756)

    Vulnerability from cvelistv5 – Published: 2026-04-13 17:11 – Updated: 2026-04-13 18:03
    VLAI
    Title
    Denial of Service Vulnerabilities in System 800xA, Symphony® Plus IEC 61850
    Summary
    A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.  The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.     This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-13 18:02 UTC
    CWE
    • CWE-1284 - Improper validation of specified quantity in input
    Impacted products
    Vendor Product Version
    ABB AC800M (System 800xA) Affected: 6.0.0x , ≤ 6.0.0303.0 (custom)
    Affected: 6.1.0x , ≤ 6.1.0031.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1004.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1202.0 (custom)
    Affected: 6.2.0x , ≤ 6.2.0006.0 (custom)
    Create a notification for this product.
    ABB Symphony Plus SD Series Affected: A_0 (custom)
    Affected: A_1 (custom)
    Affected: A_2.003 (custom)
    Affected: A_3.005 (custom)
    Affected: A_4.001 (custom)
    Affected: B_0.005 (custom)
    Create a notification for this product.
    ABB Symphony Plus MR (Melody Rack) Affected: 3.10 , ≤ 3.52 (custom)
    Create a notification for this product.
    ABB S+ Operations Affected: 2.1 (custom)
    Affected: 2.2 (custom)
    Affected: 2.3 (custom)
    Affected: 3.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3756",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-13T18:02:41.810841Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-13T18:03:41.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI868"
              ],
              "product": "AC800M (System 800xA)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.0.0303.0",
                  "status": "affected",
                  "version": "6.0.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.0031.0",
                  "status": "affected",
                  "version": "6.1.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1004.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1202.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.2.0006.0",
                  "status": "affected",
                  "version": "6.2.0x",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI850"
              ],
              "product": "Symphony Plus SD Series",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "A_0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_2.003",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_3.005",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_4.001",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "B_0.005",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "PM 877"
              ],
              "product": "Symphony Plus MR (Melody Rack)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "3.52",
                  "status": "affected",
                  "version": "3.10",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "S+ Operations",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.3",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "3.3",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB thanks Hitachi Energy for sharing the information affecting a commonly used software component."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003eA vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\u003c/div\u003e\u003cdiv\u003e\u0026nbsp; \u0026nbsp;\u003c/div\u003e\u003c/div\u003e\u003cp\u003eThis issue affects AC800M (System 800xA):\u0026nbsp;\u003cspan\u003efrom 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u00a0\n\n\n\n\nThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\n\n\u00a0 \u00a0\n\n\n\nThis issue affects AC800M (System 800xA):\u00a0from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1284",
                  "description": "CWE-1284 Improper validation of specified quantity in input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-13T17:11:08.412Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Denial of Service Vulnerabilities in System  800xA, Symphony\u00ae Plus IEC 61850",
          "x_generator": {
            "engine": "Vulnogram 1.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-3756",
        "datePublished": "2026-04-13T17:11:08.412Z",
        "dateReserved": "2025-04-17T10:42:33.414Z",
        "dateUpdated": "2026-04-13T18:03:41.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13779 (GCVE-0-2025-13779)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:11 – Updated: 2026-03-13 14:11
    VLAI
    Title
    Configuration Data Spill
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 14:11 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T14:11:49.624286Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T14:11:57.527Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:11:11.547Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Configuration Data Spill",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13779",
        "datePublished": "2026-03-13T13:11:11.547Z",
        "dateReserved": "2025-11-28T14:22:33.792Z",
        "dateUpdated": "2026-03-13T14:11:57.527Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13778 (GCVE-0-2025-13778)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:08 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Device Reboot Control
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 13:35 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:12.366891Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:18.364Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:12:03.419Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Device Reboot Control",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13778",
        "datePublished": "2026-03-13T13:08:40.380Z",
        "dateReserved": "2025-11-28T14:22:33.054Z",
        "dateUpdated": "2026-03-13T13:35:18.364Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13777 (GCVE-0-2025-13777)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:05 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Authentication Bypass due to Improper Session Validation
    Summary
    Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-13 13:35 UTC
    CWE
    • CWE-294 - Authentication bypass by capture-replay
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13777",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:31.062507Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:36.115Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication bypass by capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:05:26.329Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication Bypass due to Improper Session Validation",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13777",
        "datePublished": "2026-03-13T13:05:26.329Z",
        "dateReserved": "2025-11-28T14:22:32.497Z",
        "dateUpdated": "2026-03-13T13:35:36.115Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }