Search
Find a vulnerability
Search criteria
28 vulnerabilities found for dialink by deltaww
CVE-2025-58321 (GCVE-0-2025-58321)
Vulnerability from nvd – Published: 2025-09-11 08:50 – Updated: 2025-09-11 14:36
VLAI
EPSS
VEX
Title
DIALink - Directory Traversal Authentication Bypass Vulnerability
Summary
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-11 13:29 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
0 , ≤ 1.6.0.0
(custom)
|
Date Public
2025-09-11 07:22
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-11T13:29:52.053857Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T14:36:18.886Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Independent researcher Rangin Sima (Kamel)"
}
],
"datePublic": "2025-09-11T07:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T08:50:41.974Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58321",
"datePublished": "2025-09-11T08:50:12.379Z",
"dateReserved": "2025-08-28T06:15:58.627Z",
"dateUpdated": "2025-09-11T14:36:18.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58320 (GCVE-0-2025-58320)
Vulnerability from nvd – Published: 2025-09-11 08:51 – Updated: 2025-09-11 14:36
VLAI
EPSS
VEX
Title
DIALink - Directory Traversal Authentication Bypass Vulnerability
Summary
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
Severity
7.3 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-11 13:29 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
0 , ≤ 1.6.0.0
(custom)
|
Date Public
2025-09-11 07:22
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58320",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-11T13:29:29.552980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T14:36:13.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Independent researcher Rangin Sima (Kamel)"
}
],
"datePublic": "2025-09-11T07:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T08:51:49.981Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58320",
"datePublished": "2025-09-11T08:51:49.981Z",
"dateReserved": "2025-08-28T06:15:58.627Z",
"dateUpdated": "2025-09-11T14:36:13.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2660 (GCVE-0-2022-2660)
Vulnerability from nvd – Published: 2022-12-13 21:26 – Updated: 2025-04-16 16:04
VLAI
EPSS
VEX
Summary
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:52 UTC
CWE
- CWE-321 - Use of Hard-Coded Cryptographic Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | Industrial Automation DIALink |
Affected:
0 , ≤ 1.4.0.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:46:03.794Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:52:26.337503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:04:37.830Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Industrial Automation DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": " 1.4.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Y4er working with Trend Micro Zero Day Initiative reported this vulnerability to CISA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDelta Industrial Automation DIALink versions 1.4.0.0 and prior are\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e\n\n\u003c/p\u003e"
}
],
"value": "Delta Industrial Automation DIALink versions 1.4.0.0 and prior are\u00a0vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-Coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T21:26:57.865Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMitigation measures have been added in DIALink v1.5.0.0.\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users contact Delta Electronics \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003ecustomer service\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or a Delta Electronics representative for this release, as it will not be released publicly.\u003c/span\u003e\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "\nMitigation measures have been added in DIALink v1.5.0.0.\u00a0\n\nDelta Electronics recommends users contact Delta Electronics customer service https://www.deltaww.com/en/customerService \u00a0or a Delta Electronics representative for this release, as it will not be released publicly.\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2660",
"datePublished": "2022-12-13T21:26:57.865Z",
"dateReserved": "2022-08-04T14:26:47.606Z",
"dateUpdated": "2025-04-16T16:04:37.830Z",
"requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2969 (GCVE-0-2022-2969)
Vulnerability from nvd – Published: 2022-12-01 17:08 – Updated: 2025-04-16 16:05
VLAI
EPSS
VEX
Title
ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal
Summary
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:49 UTC
CWE
- CWE-22 - Path Traversa
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Industrial Automation | DIALink |
Affected:
0 , < 1.5.0.0 Beta 4
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:53:00.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2969",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:49:14.906906Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:05:33.867Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DIALink",
"vendor": "Delta Industrial Automation",
"versions": [
{
"lessThan": "1.5.0.0 Beta 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Y4er, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory."
}
],
"value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Path Traversa",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-01T17:08:19.327Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2969",
"datePublished": "2022-12-01T17:08:19.327Z",
"dateReserved": "2022-08-23T15:43:56.589Z",
"dateUpdated": "2025-04-16T16:05:33.867Z",
"requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38488 (GCVE-0-2021-38488)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-17 03:13
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.928Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38488",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38488",
"datePublished": "2021-11-03T19:05:54.595Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:13:03.362Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38428 (GCVE-0-2021-38428)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-17 02:56
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:41.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38428",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38428",
"datePublished": "2021-11-03T19:05:41.591Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:56:47.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38424 (GCVE-0-2021-38424)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-16 20:41
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
Severity
5.9 (Medium)
CWE
- CWE-1236 - Improper Neutralization of Formula Elements in a CSV File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.181Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1236",
"description": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:22.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38424",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38424",
"datePublished": "2021-11-03T19:05:22.305Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:41:42.309Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38422 (GCVE-0-2021-38422)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-16 17:47
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
Severity
7.8 (High)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:10.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38422",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38422",
"datePublished": "2021-11-03T19:05:10.286Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:47:43.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38420 (GCVE-0-2021-38420)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-16 18:08
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.
Severity
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:35.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38420",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38420",
"datePublished": "2021-11-03T19:05:35.434Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:08:35.145Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38418 (GCVE-0-2021-38418)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-16 19:35
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.
Severity
8.8 (High)
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.386Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:03.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38418",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319 Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38418",
"datePublished": "2021-11-03T19:05:03.549Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:35:30.633Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38416 (GCVE-0-2021-38416)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-16 18:54
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
Severity
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:48.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38416",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38416",
"datePublished": "2021-11-03T19:05:48.466Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:54:21.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38411 (GCVE-0-2021-38411)
Vulnerability from nvd – Published: 2021-11-03 19:04 – Updated: 2024-09-16 23:11
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.583Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:04:57.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38411",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38411",
"datePublished": "2021-11-03T19:04:57.862Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:11:29.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38407 (GCVE-0-2021-38407)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-17 00:02
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:29.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38407",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38407",
"datePublished": "2021-11-03T19:05:29.498Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:02:16.946Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38403 (GCVE-0-2021-38403)
Vulnerability from nvd – Published: 2021-11-03 19:05 – Updated: 2024-09-17 01:01
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:15.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38403",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38403",
"datePublished": "2021-11-03T19:05:15.432Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:01:27.067Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58320 (GCVE-0-2025-58320)
Vulnerability from cvelistv5 – Published: 2025-09-11 08:51 – Updated: 2025-09-11 14:36
VLAI
EPSS
VEX
Title
DIALink - Directory Traversal Authentication Bypass Vulnerability
Summary
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
Severity
7.3 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-11 13:29 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
0 , ≤ 1.6.0.0
(custom)
|
Date Public
2025-09-11 07:22
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58320",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-11T13:29:29.552980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T14:36:13.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Independent researcher Rangin Sima (Kamel)"
}
],
"datePublic": "2025-09-11T07:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T08:51:49.981Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58320",
"datePublished": "2025-09-11T08:51:49.981Z",
"dateReserved": "2025-08-28T06:15:58.627Z",
"dateUpdated": "2025-09-11T14:36:13.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58321 (GCVE-0-2025-58321)
Vulnerability from cvelistv5 – Published: 2025-09-11 08:50 – Updated: 2025-09-11 14:36
VLAI
EPSS
VEX
Title
DIALink - Directory Traversal Authentication Bypass Vulnerability
Summary
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-11 13:29 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
0 , ≤ 1.6.0.0
(custom)
|
Date Public
2025-09-11 07:22
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-11T13:29:52.053857Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T14:36:18.886Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.6.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Independent researcher Rangin Sima (Kamel)"
}
],
"datePublic": "2025-09-11T07:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-11T08:50:41.974Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58321",
"datePublished": "2025-09-11T08:50:12.379Z",
"dateReserved": "2025-08-28T06:15:58.627Z",
"dateUpdated": "2025-09-11T14:36:18.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2660 (GCVE-0-2022-2660)
Vulnerability from cvelistv5 – Published: 2022-12-13 21:26 – Updated: 2025-04-16 16:04
VLAI
EPSS
VEX
Summary
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:52 UTC
CWE
- CWE-321 - Use of Hard-Coded Cryptographic Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | Industrial Automation DIALink |
Affected:
0 , ≤ 1.4.0.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:46:03.794Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:52:26.337503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:04:37.830Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Industrial Automation DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": " 1.4.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Y4er working with Trend Micro Zero Day Initiative reported this vulnerability to CISA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDelta Industrial Automation DIALink versions 1.4.0.0 and prior are\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e\n\n\u003c/p\u003e"
}
],
"value": "Delta Industrial Automation DIALink versions 1.4.0.0 and prior are\u00a0vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-Coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T21:26:57.865Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMitigation measures have been added in DIALink v1.5.0.0.\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users contact Delta Electronics \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003ecustomer service\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or a Delta Electronics representative for this release, as it will not be released publicly.\u003c/span\u003e\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "\nMitigation measures have been added in DIALink v1.5.0.0.\u00a0\n\nDelta Electronics recommends users contact Delta Electronics customer service https://www.deltaww.com/en/customerService \u00a0or a Delta Electronics representative for this release, as it will not be released publicly.\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2660",
"datePublished": "2022-12-13T21:26:57.865Z",
"dateReserved": "2022-08-04T14:26:47.606Z",
"dateUpdated": "2025-04-16T16:04:37.830Z",
"requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2969 (GCVE-0-2022-2969)
Vulnerability from cvelistv5 – Published: 2022-12-01 17:08 – Updated: 2025-04-16 16:05
VLAI
EPSS
VEX
Title
ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal
Summary
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:49 UTC
CWE
- CWE-22 - Path Traversa
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Industrial Automation | DIALink |
Affected:
0 , < 1.5.0.0 Beta 4
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:53:00.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2969",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:49:14.906906Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:05:33.867Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DIALink",
"vendor": "Delta Industrial Automation",
"versions": [
{
"lessThan": "1.5.0.0 Beta 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Y4er, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory."
}
],
"value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Path Traversa",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-01T17:08:19.327Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2969",
"datePublished": "2022-12-01T17:08:19.327Z",
"dateReserved": "2022-08-23T15:43:56.589Z",
"dateUpdated": "2025-04-16T16:05:33.867Z",
"requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38488 (GCVE-0-2021-38488)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-17 03:13
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.928Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38488",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38488",
"datePublished": "2021-11-03T19:05:54.595Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:13:03.362Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38416 (GCVE-0-2021-38416)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 18:54
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
Severity
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:48.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38416",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38416",
"datePublished": "2021-11-03T19:05:48.466Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:54:21.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38428 (GCVE-0-2021-38428)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-17 02:56
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:41.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38428",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38428",
"datePublished": "2021-11-03T19:05:41.591Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:56:47.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38420 (GCVE-0-2021-38420)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 18:08
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.
Severity
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:35.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38420",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38420",
"datePublished": "2021-11-03T19:05:35.434Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:08:35.145Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38407 (GCVE-0-2021-38407)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-17 00:02
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:29.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38407",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38407",
"datePublished": "2021-11-03T19:05:29.498Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:02:16.946Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38424 (GCVE-0-2021-38424)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 20:41
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
Severity
5.9 (Medium)
CWE
- CWE-1236 - Improper Neutralization of Formula Elements in a CSV File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.181Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1236",
"description": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:22.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38424",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38424",
"datePublished": "2021-11-03T19:05:22.305Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:41:42.309Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38403 (GCVE-0-2021-38403)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-17 01:01
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:15.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38403",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38403",
"datePublished": "2021-11-03T19:05:15.432Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:01:27.067Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38422 (GCVE-0-2021-38422)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 17:47
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
Severity
7.8 (High)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:10.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38422",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38422",
"datePublished": "2021-11-03T19:05:10.286Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:47:43.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38418 (GCVE-0-2021-38418)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 19:35
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.
Severity
8.8 (High)
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.386Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:05:03.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38418",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319 Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38418",
"datePublished": "2021-11-03T19:05:03.549Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:35:30.633Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38411 (GCVE-0-2021-38411)
Vulnerability from cvelistv5 – Published: 2021-11-03 19:04 – Updated: 2024-09-16 23:11
VLAI
EPSS
VEX
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code.
Severity
5.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIALink |
Affected:
All , ≤ 1.2.4.0
(custom)
|
Date Public
2021-10-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.583Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIALink",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.2.4.0",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-03T19:04:57.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
],
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DIALink",
"workarounds": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
"ID": "CVE-2021-38411",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DIALink"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIALink",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "1.2.4.0"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
}
]
},
"source": {
"advisory": "ICSA-21-294-02",
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38411",
"datePublished": "2021-11-03T19:04:57.862Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:11:29.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}