VDE-2026-155

Vulnerability from csaf_welotecgmbh - Published: 2026-11-16 11:00 - Updated: 2026-11-16 11:00
Summary
Welotec: IPv4 TCP Use-After-Free in egOS
Severity
Critical
Notes
Summary: The Linux kernel used by the affected egOS releases contains a use-after-free vulnerability in the IPv4 TCP connection-handling path. An unauthenticated remote attacker can send specially crafted IPv4 TCP packets containing IP options to a listening service and race retransmitted connection requests against connection establishment or teardown. Successful exploitation may disclose or corrupt kernel memory, crash the device, or potentially allow arbitrary code execution with kernel privileges.
Impact: Successful exploitation may expose adjacent kernel heap contents, cause out-of-bounds writes and kernel memory corruption, or crash the affected device and make it unavailable. Under suitable conditions, memory corruption may allow arbitrary code execution with kernel privileges and complete compromise of the device. Researchers have demonstrated unauthenticated remote code execution against systems with a Multipath TCP listener.
Mitigation: - Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks. - Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN. - At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected. - Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability. - Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.
Remediation: Update egOS on all affected products to version 1.11.2 or later.

In the Linux kernel, the following vulnerability has been resolved: ipv4: free inet_opt and ireq_opt after an RCU grace period tcp_v4_syn_recv_sock() transfers ownership of ireq->ireq_opt to the child socket (newinet->inet_opt) without copying it. Another cpu can concurrently process a retransmitted SYN for the same request socket, and send a SYNACK from tcp_check_req(). tcp_v4_send_synack() and inet_csk_route_req() read ireq->ireq_opt under rcu_read_lock() only, and ip_build_and_send_pkt() and ip_options_build() then read opt->optlen twice. Note that the SYNACK timer itself is not an issue: it holds a reference on its request socket, and inet_csk_reqsk_queue_drop() calls timer_delete_sync() before the child can be freed. Since commit 079096f103fa ("tcp/dccp: install syn_recv requests into ehash table"), request sockets are processed without holding the listener lock, so nothing prevents the child socket from being freed while the SYNACK is still being built. TCP child sockets do not have SOCK_RCU_FREE, and inet_sock_destruct() frees inet_opt with a plain kfree(), leading to a use-after-free in ip_options_build(). A similar issue exists with request socket migration (net.ipv4.tcp_migrate_req=1, or a BPF_SK_REUSEPORT_SELECT_OR_MIGRATE program). reqsk_timer_handler() clones the request socket with inet_reqsk_clone(), so that the old request socket and its clone share the same ireq_opt, then reqsk_migrate_reset() clears the pointer in the old one. Another cpu holding a reference on the old request socket can still be using these options (sending a SYNACK, or creating a child in tcp_v4_syn_recv_sock()) when the clone is freed, and tcp_v4_reqsk_destructor() also uses a plain kfree(). Readers already use RCU, and other paths replacing inet_opt (do_ip_setsockopt(), cipso_v4_sock_setattr()...) already use kfree_rcu(). Use kfree_rcu() in inet_sock_destruct() and tcp_v4_reqsk_destructor() as well. IPv6 is not affected by the first issue, because tcp_v6_syn_recv_sock() duplicates the options. tcp_v6_reqsk_destructor() has the same migration issue with ipv6_opt, which is only set by CALIPSO. This will be addressed in a separate patch.

CWE-416 - Use After Free
Mitigation - Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks. - Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN. - At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected. - Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability. - Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.
Vendor Fix Update egOS on all affected products to version 1.11.2 or later.
Affected products
Product Identifier Version Remediation
Unresolved product id: CSAFPID-32001 —
Unresolved product id: CSAFPID-32002 —
Unresolved product id: CSAFPID-32003 —
Unresolved product id: CSAFPID-32004 —
Unresolved product id: CSAFPID-32005 —
Unresolved product id: CSAFPID-32006 —
Product Identifier Version Remediation
Unresolved product id: CSAFPID-31001 —
Unresolved product id: CSAFPID-31002 —
Unresolved product id: CSAFPID-31003 —
Unresolved product id: CSAFPID-31004 —
Unresolved product id: CSAFPID-31005 —
Unresolved product id: CSAFPID-31006 —

{
  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      },
      {
        "names": [
          "Xinyang Ge"
        ],
        "organization": "Anthropic",
        "summary": "reporting the underlying Linux kernel vulnerability"
      }
    ],
    "aggregate_severity": {
      "namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
      "text": "Critical"
    },
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "The Linux kernel used by the affected egOS releases contains a use-after-free vulnerability in the IPv4 TCP connection-handling path. An unauthenticated remote attacker can send specially crafted IPv4 TCP packets containing IP options to a listening service and race retransmitted connection requests against connection establishment or teardown. Successful exploitation may disclose or corrupt kernel memory, crash the device, or potentially allow arbitrary code execution with kernel privileges.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "Successful exploitation may expose adjacent kernel heap contents, cause out-of-bounds writes and kernel memory corruption, or crash the affected device and make it unavailable. Under suitable conditions, memory corruption may allow arbitrary code execution with kernel privileges and complete compromise of the device. Researchers have demonstrated unauthenticated remote code execution against systems with a Multipath TCP listener.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "- Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks.\n- Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN.\n- At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected.\n- Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability.\n- Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.",
        "title": "Mitigation"
      },
      {
        "category": "description",
        "text": "Update egOS on all affected products to version 1.11.2 or later.",
        "title": "Remediation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@welotec.com",
      "name": "Welotec GmbH",
      "namespace": "https://welotec.com"
    },
    "references": [
      {
        "category": "external",
        "summary": "Welotec PSIRT",
        "url": "https://welotec.com/de/pages/coordinated-vulnerability-disclosure-policy"
      },
      {
        "category": "external",
        "summary": "CERT@VDE Security Advisories for Welotec",
        "url": "https://certvde.com/de/advisories/vendor/welotec"
      },
      {
        "category": "self",
        "summary": "VDE-2026-155: Welotec: IPv4 TCP Use-After-Free in egOS - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2026-155/"
      },
      {
        "category": "self",
        "summary": "VDE-2026-155: Welotec: IPv4 TCP Use-After-Free in egOS - CSAF",
        "url": "https://welotec.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-155.json"
      }
    ],
    "title": "Welotec: IPv4 TCP Use-After-Free in egOS",
    "tracking": {
      "aliases": [
        "VDE-2026-155"
      ],
      "current_release_date": "2026-11-16T11:00:00.000Z",
      "generator": {
        "date": "2026-11-16T10:08:25.236Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.6.16"
        }
      },
      "id": "VDE-2026-155",
      "initial_release_date": "2026-11-16T11:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-11-16T11:00:00.000Z",
          "number": "1.0.0",
          "summary": "Initial release"
        }
      ],
      "status": "final",
      "version": "1.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_name",
                    "name": "EG400 Mk2",
                    "product": {
                      "name": "EG400 Mk2",
                      "product_id": "CSAFPID-11001",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg400_mk2:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG400Mk2-D11001-000101",
                          "EG400Mk2-D11101-000101"
                        ],
                        "skus": [
                          "WEG500100210",
                          "WEG500100580"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_name",
                    "name": "EG500",
                    "product": {
                      "name": "EG500",
                      "product_id": "CSAFPID-11002",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg500_mk1:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG503W",
                          "EG503L",
                          "EG503W_4GB",
                          "EG503L_4GB",
                          "EG503L-G"
                        ],
                        "skus": [
                          "WEG500100010",
                          "WEG500100020",
                          "WEG500100030",
                          "WEG500100040",
                          "WEG500100130"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_name",
                    "name": "EG500 Mk2",
                    "product": {
                      "name": "EG500 Mk2",
                      "product_id": "CSAFPID-11003",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg500_mk2:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG500Mk2-A11101-000101",
                          "EG500Mk2-A11001-000101",
                          "EG500Mk2-B11101-000101",
                          "EG500Mk2-B11001-000101",
                          "EG500Mk2-C11101-000101",
                          "EG500Mk2-C11001-000101",
                          "EG500Mk2-A12011-000101",
                          "EG500Mk2-A11001-000201",
                          "EG500Mk2-A21101-000101"
                        ],
                        "skus": [
                          "WEG500100160",
                          "WEG500100170",
                          "WEG500100180",
                          "WEG500100190",
                          "WEG500100260",
                          "WEG500100270",
                          "WEG500100280",
                          "WEG500100290",
                          "WEG500100650"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_name",
                    "name": "EG600",
                    "product": {
                      "name": "EG600",
                      "product_id": "CSAFPID-11004",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg600_mk1:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG602W",
                          "EG602L"
                        ],
                        "skus": [
                          "WEG600100010",
                          "WEG600100020"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_name",
                    "name": "EG600 Mk2",
                    "product": {
                      "name": "EG600 Mk2",
                      "product_id": "CSAFPID-11005",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg600_mk2:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG603W Mk2",
                          "EG603L Mk2"
                        ],
                        "skus": [
                          "WEG600100140",
                          "WEG600100150"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_name",
                    "name": "EG800",
                    "product": {
                      "name": "EG800",
                      "product_id": "CSAFPID-11006",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:h:welotec:eg800_mk1:*:*:*:*:*:*:*:*",
                        "model_numbers": [
                          "EG802W",
                          "EG804W",
                          "EG802W_i7_512GB_DinRail",
                          "EG802W_i7_512GB_w/o DinRail",
                          "EG804W Pro"
                        ],
                        "skus": [
                          "WEG800100010",
                          "WEG800100020",
                          "WEG800100040",
                          "WEG800100050",
                          "WEG800100090"
                        ]
                      }
                    }
                  }
                ],
                "category": "product_family",
                "name": "Edge Gateways"
              }
            ],
            "category": "product_family",
            "name": "Hardware"
          },
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "vers:semver/\u003e=0.0.0|\u003c1.11.2",
                    "product": {
                      "name": "egOS \u003c1.11.2",
                      "product_id": "CSAFPID-21001",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:*:*"
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "1.11.2",
                    "product": {
                      "name": "egOS 1.11.2",
                      "product_id": "CSAFPID-22001",
                      "product_identification_helper": {
                        "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:*:*"
                      }
                    }
                  }
                ],
                "category": "product_name",
                "name": "egOS"
              }
            ],
            "category": "product_family",
            "name": "Firmware"
          }
        ],
        "category": "vendor",
        "name": "Welotec"
      }
    ],
    "product_groups": [
      {
        "group_id": "CSAFGID-0001",
        "product_ids": [
          "CSAFPID-31001",
          "CSAFPID-31002",
          "CSAFPID-31003",
          "CSAFPID-31004",
          "CSAFPID-31005",
          "CSAFPID-31006"
        ],
        "summary": "Affected products running egOS versions earlier than 1.11.2."
      },
      {
        "group_id": "CSAFGID-0002",
        "product_ids": [
          "CSAFPID-32001",
          "CSAFPID-32002",
          "CSAFPID-32003",
          "CSAFPID-32004",
          "CSAFPID-32005",
          "CSAFPID-32006"
        ],
        "summary": "Fixed products running egOS 1.11.2."
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG400 Mk2",
          "product_id": "CSAFPID-31001",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg400_mk2:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG500",
          "product_id": "CSAFPID-31002",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg500_mk1:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11002"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG500 Mk2",
          "product_id": "CSAFPID-31003",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg500_mk2:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11003"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG600",
          "product_id": "CSAFPID-31004",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg600_mk1:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11004"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG600 Mk2",
          "product_id": "CSAFPID-31005",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg600_mk2:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11005"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS \u003c1.11.2 installed on EG800",
          "product_id": "CSAFPID-31006",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:*:*:*:*:*:*:eg800_mk1:*"
          }
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11006"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG400 Mk2",
          "product_id": "CSAFPID-32001",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg400_mk2:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG500",
          "product_id": "CSAFPID-32002",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg500_mk1:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11002"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG500 Mk2",
          "product_id": "CSAFPID-32003",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg500_mk2:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11003"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG600",
          "product_id": "CSAFPID-32004",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg600_mk1:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11004"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG600 Mk2",
          "product_id": "CSAFPID-32005",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg600_mk2:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11005"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "egOS 1.11.2 installed on EG800",
          "product_id": "CSAFPID-32006",
          "product_identification_helper": {
            "cpe": "cpe:2.3:o:welotec:egos:1.11.2:*:*:*:*:*:eg800_mk1:*"
          }
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11006"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2026-98432",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "description",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nipv4: free inet_opt and ireq_opt after an RCU grace period\n\ntcp_v4_syn_recv_sock() transfers ownership of ireq-\u003eireq_opt to the\nchild socket (newinet-\u003einet_opt) without copying it.\n\nAnother cpu can concurrently process a retransmitted SYN for the same\nrequest socket, and send a SYNACK from tcp_check_req().\ntcp_v4_send_synack() and inet_csk_route_req() read ireq-\u003eireq_opt\nunder rcu_read_lock() only, and ip_build_and_send_pkt() and\nip_options_build() then read opt-\u003eoptlen twice.\n\nNote that the SYNACK timer itself is not an issue: it holds a\nreference on its request socket, and inet_csk_reqsk_queue_drop()\ncalls timer_delete_sync() before the child can be freed.\n\nSince commit 079096f103fa (\"tcp/dccp: install syn_recv requests\ninto ehash table\"), request sockets are processed without holding\nthe listener lock, so nothing prevents the child socket from being\nfreed while the SYNACK is still being built. TCP child sockets do\nnot have SOCK_RCU_FREE, and inet_sock_destruct() frees inet_opt\nwith a plain kfree(), leading to a use-after-free in\nip_options_build().\n\nA similar issue exists with request socket migration\n(net.ipv4.tcp_migrate_req=1, or a BPF_SK_REUSEPORT_SELECT_OR_MIGRATE\nprogram). reqsk_timer_handler() clones the request socket with\ninet_reqsk_clone(), so that the old request socket and its clone\nshare the same ireq_opt, then reqsk_migrate_reset() clears the\npointer in the old one. Another cpu holding a reference on the old\nrequest socket can still be using these options (sending a SYNACK,\nor creating a child in tcp_v4_syn_recv_sock()) when the clone is\nfreed, and tcp_v4_reqsk_destructor() also uses a plain kfree().\n\nReaders already use RCU, and other paths replacing inet_opt\n(do_ip_setsockopt(), cipso_v4_sock_setattr()...) already use\nkfree_rcu(). Use kfree_rcu() in inet_sock_destruct() and\ntcp_v4_reqsk_destructor() as well.\n\nIPv6 is not affected by the first issue, because tcp_v6_syn_recv_sock()\nduplicates the options. tcp_v6_reqsk_destructor() has the same\nmigration issue with ipv6_opt, which is only set by CALIPSO. This\nwill be addressed in a separate patch.",
          "title": "CVE description"
        },
        {
          "category": "summary",
          "text": "The affected Linux kernel transfers IPv4 options from a TCP request socket to a child socket without copying them. Concurrent processing of a retransmitted SYN packet or request-socket migration may free the options while another CPU still uses them to construct a SYN-ACK packet. An unauthenticated remote attacker can trigger this race with crafted IPv4 TCP traffic containing Record Route or Timestamp options.",
          "title": "Vulnerability summary"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-32001",
          "CSAFPID-32002",
          "CSAFPID-32003",
          "CSAFPID-32004",
          "CSAFPID-32005",
          "CSAFPID-32006"
        ],
        "known_affected": [
          "CSAFPID-31001",
          "CSAFPID-31002",
          "CSAFPID-31003",
          "CSAFPID-31004",
          "CSAFPID-31005",
          "CSAFPID-31006"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "CVE Record: CVE-2026-98432",
          "url": "https://www.cve.org/CVERecord?id=CVE-2026-98432"
        },
        {
          "category": "external",
          "summary": "CVSS v4.0 Score: 9.3 / Critical",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "- Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks.\n- Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN.\n- At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected.\n- Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability.\n- Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.",
          "group_ids": [
            "CSAFGID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update egOS on all affected products to version 1.11.2 or later.",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31001",
            "CSAFPID-31002",
            "CSAFPID-31003",
            "CSAFPID-31004",
            "CSAFPID-31005",
            "CSAFPID-31006"
          ]
        }
      ],
      "title": "ipv4: free inet_opt and ireq_opt after an RCU grace period"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…