SSA-970803
Vulnerability from csaf_siemens - Published: 2026-11-10 00:00 - Updated: 2026-11-10 00:00Summary
SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems
Notes
Summary: The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user.
Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.
7.5 (High)
Affected products
Known affected
14 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC BATCH V9.1
Siemens / SIMATIC BATCH V9.1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC WinCC Runtime Professional V20
Siemens / SIMATIC WinCC Runtime Professional V20
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Runtime Professional V21
Siemens / SIMATIC WinCC Runtime Professional V21
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC V7.5
Siemens / SIMATIC WinCC V7.5
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC V8.0
Siemens / SIMATIC WinCC V8.0
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC V8.1
Siemens / SIMATIC WinCC V8.1
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC Information Server 2020
Siemens / SIMATIC Information Server 2020
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC Information Server 2022
Siemens / SIMATIC Information Server 2022
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC PCS 7 V9.1
Siemens / SIMATIC PCS 7 V9.1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC Process Historian 2020
Siemens / SIMATIC Process Historian 2020
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC Process Historian 2022
Siemens / SIMATIC Process Historian 2022
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC WinCC Runtime Professional V17
Siemens / SIMATIC WinCC Runtime Professional V17
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Runtime Professional V18
Siemens / SIMATIC WinCC Runtime Professional V18
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Runtime Professional V19
Siemens / SIMATIC WinCC Runtime Professional V19
|
vers:all/* |
Mitigation
None Available
|
References
2 references
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user.\n\nSiemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-970803.html"
},
{
"category": "self",
"summary": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-970803.json"
}
],
"title": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems",
"tracking": {
"current_release_date": "2026-11-10T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-970803",
"initial_release_date": "2026-11-10T00:00:00.000Z",
"revision_history": [
{
"date": "2026-11-10T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC BATCH V9.1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V9.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Information Server 2020",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC Information Server 2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Information Server 2022",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC Information Server 2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V9.1",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V9.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Process Historian 2020",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC Process Historian 2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Process Historian 2022",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC Process Historian 2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional V17",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional V18",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional V19",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional V20",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional V21",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V21"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC V7.5",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7.5"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC V8.0",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V8.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC V8.1",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V8.1"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-58114",
"cwe": {
"id": "CWE-1390",
"name": "Weak Authentication"
},
"notes": [
{
"category": "description",
"text": "Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"10",
"11",
"12",
"13",
"14",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635\u0026lc=en-ID",
"product_ids": [
"1",
"10",
"11",
"12",
"13",
"14",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"10",
"11",
"12",
"13",
"14",
"7",
"8",
"9"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"10",
"11",
"12",
"13",
"14",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2026-58114"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…