SSA-242944
Vulnerability from csaf_siemens - Published: 2026-11-10 00:00 - Updated: 2026-11-10 00:00A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
COMOS Walkinside
Siemens / COMOS Walkinside
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Runtime Professional
Siemens / SIMATIC WinCC Runtime Professional
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified for Industrial Edge
Siemens / SIMATIC WinCC Unified for Industrial Edge
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified PC Runtime
Siemens / SIMATIC WinCC Unified PC Runtime
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified SIQENCE
Siemens / SIMATIC WinCC Unified SIQENCE
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC V7/V8
Siemens / SIMATIC WinCC V7/V8
|
vers:all/* |
Mitigation
None Available
|
|
|
TIA Administrator
Siemens / TIA Administrator
|
vers:all/* |
Mitigation
None Available
|
|
|
User Management Component (UMC)
Siemens / User Management Component (UMC)
|
vers:all/* |
Mitigation
None Available
|
|
|
Project Server Web Administration Tool
Siemens / Project Server Web Administration Tool
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC BRAUMAT >= V8.2 Update 1 < V8.2 Update 5
Siemens / SIMATIC BRAUMAT
|
vers:intdot/>=8.2.0.1|<8.2.0.5 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC Profiling Tool
Siemens / SIMATIC Profiling Tool
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC SISTAR >= V8.2 Update 1 < V8.2 Update 5
Siemens / SIMATIC SISTAR
|
vers:intdot/>=8.2.0.1|<8.2.0.5 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinCC Companion
Siemens / SIMATIC WinCC Companion
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC OA V3.20 < V3.20 P17.1
Siemens / SIMATIC WinCC OA V3.20
|
vers:intdot/<3.20.17.1 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC OA V3.21
Siemens / SIMATIC WinCC OA V3.21
|
vers:all/* |
Mitigation
None Available
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
gDAP (gPROMS Digital Application Platform)
Siemens / gDAP (gPROMS Digital Application Platform)
|
vers:all/* |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens products.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-242944: Node2Shell Vulnerability in Siemens Industrial Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
},
{
"category": "self",
"summary": "SSA-242944: Node2Shell Vulnerability in Siemens Industrial Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-242944.json"
}
],
"title": "SSA-242944: Node2Shell Vulnerability in Siemens Industrial Products",
"tracking": {
"current_release_date": "2026-11-10T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-242944",
"initial_release_date": "2026-11-10T00:00:00.000Z",
"revision_history": [
{
"date": "2026-11-10T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "COMOS Walkinside",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "COMOS Walkinside"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "gDAP (gPROMS Digital Application Platform)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "gDAP (gPROMS Digital Application Platform)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Project Server Web Administration Tool",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Project Server Web Administration Tool"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=8.2.0.1|\u003c8.2.0.5",
"product": {
"name": "SIMATIC BRAUMAT \u003e= V8.2 Update 1 \u003c V8.2 Update 5",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC BRAUMAT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Profiling Tool",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC Profiling Tool"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=8.2.0.1|\u003c8.2.0.5",
"product": {
"name": "SIMATIC SISTAR \u003e= V8.2 Update 1 \u003c V8.2 Update 5",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC SISTAR"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Companion",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Companion"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.20.17.1",
"product": {
"name": "SIMATIC WinCC OA V3.20 \u003c V3.20 P17.1",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC OA V3.21",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.21"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified for Industrial Edge",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified for Industrial Edge"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified PC Runtime",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified PC Runtime"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified SIQENCE",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified SIQENCE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC V7/V8",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7/V8"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "TIA Administrator",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "TIA Administrator"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "User Management Component (UMC)",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "User Management Component (UMC)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-111497",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"2"
]
}
],
"notes": [
{
"category": "description",
"text": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\r\n\r\n\r\n\r\n\r\n\r\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
],
"known_not_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required",
"product_ids": [
"1",
"10",
"11",
"12",
"13",
"14",
"3",
"4",
"5",
"6",
"7",
"9"
]
},
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. If UMC authentication is enabled, block requests that use Brotli compression: in IIS Manager, select the Default Web Site, open \"Request Filtering\" \u003e \"Rules\", click \"Add Filtering Rule\", enter Name \"CVE-2026-111497\", Scan Headers \"Content-Encoding\" and Deny Strings \"br\", then click OK.",
"product_ids": [
"15"
]
},
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. In IIS Manager, select the Default Web Site, open \"Request Filtering\" \u003e \"Rules\", click \"Add Filtering Rule\", enter Name \"CVE-2026-111497\", Scan Headers \"Content-Encoding\" and Deny Strings \"br\", then click OK.",
"product_ids": [
"16"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"5"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"3",
"7",
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.20 P17.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/110007354/"
},
{
"category": "vendor_fix",
"details": "Update to V8.2 Update 5 or later version",
"product_ids": [
"4",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109976926/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"threats": [
{
"category": "impact",
"details": "not shipped as part of the product",
"product_ids": [
"2"
]
}
],
"title": "CVE-2026-111497"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.