ICSMA-18-219-01
Vulnerability from csaf_cisa - Published: 2018-08-07 06:00 - Updated: 2026-05-07 06:00Summary
Medtronic MyCareLink 24950 Patient Monitor (Update A)
Notes
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Summary: Successful exploitation of these vulnerabilities may allow an attacker with physical access to obtain per-product credentials that are utilized to authenticate data uploads and encrypt data at rest. Additionally, an attacker with access to a set of these credentials and additional identifiers can upload invalid data to the Medtronic CareLink network.
Critical infrastructure sectors: Healthcare and Public Health
Countries/areas deployed: Worldwide
Company headquarters location: Ireland
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices: No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.
4.4 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Medtronic 24950 MyCareLink Monitor: vers:all/*
Medtronic / 24950 MyCareLink Monitor
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
fix
|
|
|
Medtronic 24952 MyCareLink Monitor: vers:all/*
Medtronic / 24952 MyCareLink Monitor
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
fix
Mitigation
fix
|
6.8 (Medium)
Affected products
Known affected
2 products, the same list as for
CVE-2018-10626
References
18 references
{
"document": {
"acknowledgments": [
{
"names": [
"Billy Rios",
"Jesse Young",
"Jonathan Butts"
],
"organization": "Whitescope LLC",
"summary": "reported these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities may allow an attacker with physical access to obtain per-product credentials that are utilized to authenticate data uploads and encrypt data at rest. Additionally, an attacker with access to a set of these credentials and additional identifiers can upload invalid data to the Medtronic CareLink network.",
"title": "Advisory Summary"
},
{
"category": "other",
"text": "Healthcare and Public Health",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Ireland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSMA-18-219-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsma-18-219-01.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSMA-18-219-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
}
],
"title": "Medtronic MyCareLink 24950 Patient Monitor (Update A)",
"tracking": {
"current_release_date": "2026-05-07T06:00:00.000000Z",
"generator": {
"date": "2026-05-06T16:46:07.241856Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSMA-18-219-01",
"initial_release_date": "2018-08-07T06:00:00.000000Z",
"revision_history": [
{
"date": "2018-08-07T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2026-05-07T06:00:00.000000Z",
"legacy_version": "Update A",
"number": "2",
"summary": "Update A - Updated CVE-2018-10622 description and CVSS score and vector score."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Medtronic 24950 MyCareLink Monitor: vers:all/*",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "24950 MyCareLink Monitor"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Medtronic 24952 MyCareLink Monitor: vers:all/*",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "24952 MyCareLink Monitor"
}
],
"category": "vendor",
"name": "Medtronic"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-10626",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "summary",
"text": "The affected product\u0027s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.",
"title": "Vulnerability Summary"
},
{
"category": "details",
"text": "SSVCv2/E:N/A:N/2026-05-06T06:00:00.000000Z",
"title": "SSVC"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/345.html"
},
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-10626"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Medtronic has made server-side updates to address the insufficient verification vulnerability identified in this advisory. Medtronic is implementing additional server-side mitigations to enhance data integrity and authenticity.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Maintain good physical control over the home monitor.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Medtronic has released additional patient focused information, at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "https://www.medtronic.com/security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.medtronic.com/security"
},
{
"category": "mitigation",
"details": "Users should follow CISA\u0027s guidance in the following areas:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Securing the Internet of Things",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.cisa.gov/news-events/news/securing-internet-things-iot"
},
{
"category": "mitigation",
"details": "Home Network Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.cisa.gov/news-events/news/home-network-security"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2018-10622",
"cwe": {
"id": "CWE-313",
"name": "Cleartext Storage in a File or on Disk"
},
"notes": [
{
"category": "summary",
"text": "Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.",
"title": "Vulnerability Summary"
},
{
"category": "details",
"text": "SSVCv2/E:N/A:N/2026-05-06T06:00:00.000000Z",
"title": "SSVC"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/313.html"
},
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-10622"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Medtronic has made server-side updates to address the insufficient verification vulnerability identified in this advisory. Medtronic is implementing additional server-side mitigations to enhance data integrity and authenticity.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Maintain good physical control over the home monitor.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Medtronic has released additional patient focused information, at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "https://www.medtronic.com/security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.medtronic.com/security"
},
{
"category": "mitigation",
"details": "Users should follow CISA\u0027s guidance in the following areas:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Securing the Internet of Things",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.cisa.gov/news-events/news/securing-internet-things-iot"
},
{
"category": "mitigation",
"details": "Home Network Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.cisa.gov/news-events/news/home-network-security"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…