ICSA-26-321-03
Vulnerability from csaf_cisa - Published: 2026-11-10 00:00 - Updated: 2026-11-17 07:00A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
COMOS Walkinside
Siemens / COMOS Walkinside
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Runtime Professional
Siemens / SIMATIC WinCC Runtime Professional
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified for Industrial Edge
Siemens / SIMATIC WinCC Unified for Industrial Edge
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified PC Runtime
Siemens / SIMATIC WinCC Unified PC Runtime
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC Unified SIQENCE
Siemens / SIMATIC WinCC Unified SIQENCE
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC V7/V8
Siemens / SIMATIC WinCC V7/V8
|
vers:all/* |
Mitigation
None Available
|
|
|
TIA Administrator
Siemens / TIA Administrator
|
vers:all/* |
Mitigation
None Available
|
|
|
User Management Component (UMC)
Siemens / User Management Component (UMC)
|
vers:all/* |
Mitigation
None Available
|
|
|
Project Server Web Administration Tool
Siemens / Project Server Web Administration Tool
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC BRAUMAT >= V8.2 Update 1 < V8.2 Update 5
Siemens / SIMATIC BRAUMAT
|
vers:intdot/>=8.2.0.1|<8.2.0.5 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC Profiling Tool
Siemens / SIMATIC Profiling Tool
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC SISTAR >= V8.2 Update 1 < V8.2 Update 5
Siemens / SIMATIC SISTAR
|
vers:intdot/>=8.2.0.1|<8.2.0.5 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinCC Companion
Siemens / SIMATIC WinCC Companion
|
vers:all/* |
Mitigation
None Available
|
|
|
SIMATIC WinCC OA V3.20 < V3.20 P17.1
Siemens / SIMATIC WinCC OA V3.20
|
vers:intdot/<3.20.17.1 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC OA V3.21
Siemens / SIMATIC WinCC OA V3.21
|
vers:all/* |
Mitigation
None Available
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
gDAP (gPROMS Digital Application Platform)
Siemens / gDAP (gPROMS Digital Application Platform)
|
vers:all/* |
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens products.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-242944 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "Critical Manufacturing, Food and Agriculture, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-242944: Node2Shell Vulnerability in Siemens Industrial Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-242944.json"
},
{
"category": "self",
"summary": "SSA-242944: Node2Shell Vulnerability in Siemens Industrial Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-321-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-321-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-321-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens Industrial Automation Software Products",
"tracking": {
"current_release_date": "2026-11-17T07:00:00.000000Z",
"generator": {
"date": "2026-11-13T01:35:40.790610Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-321-03",
"initial_release_date": "2026-11-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2026-11-10T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-11-17T07:00:00.000000Z",
"legacy_version": "CISA Republication",
"number": "2",
"summary": "Initial CISA Republication of Siemens ProductCERT SSA-242944 advisory"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "COMOS Walkinside",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "COMOS Walkinside"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "gDAP (gPROMS Digital Application Platform)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "gDAP (gPROMS Digital Application Platform)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Project Server Web Administration Tool",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Project Server Web Administration Tool"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=8.2.0.1|\u003c8.2.0.5",
"product": {
"name": "SIMATIC BRAUMAT \u003e= V8.2 Update 1 \u003c V8.2 Update 5",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SIMATIC BRAUMAT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Profiling Tool",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC Profiling Tool"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=8.2.0.1|\u003c8.2.0.5",
"product": {
"name": "SIMATIC SISTAR \u003e= V8.2 Update 1 \u003c V8.2 Update 5",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC SISTAR"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Companion",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Companion"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.20.17.1",
"product": {
"name": "SIMATIC WinCC OA V3.20 \u003c V3.20 P17.1",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC OA V3.21",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.21"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Runtime Professional",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified for Industrial Edge",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified for Industrial Edge"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified PC Runtime",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified PC Runtime"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC Unified SIQENCE",
"product_id": "CSAFPID-0013"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Unified SIQENCE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinCC V7/V8",
"product_id": "CSAFPID-0014"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7/V8"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "TIA Administrator",
"product_id": "CSAFPID-0015"
}
}
],
"category": "product_name",
"name": "TIA Administrator"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "User Management Component (UMC)",
"product_id": "CSAFPID-0016"
}
}
],
"category": "product_name",
"name": "User Management Component (UMC)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-111497",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"CSAFPID-0002"
]
}
],
"notes": [
{
"category": "description",
"text": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\r\n\r\n\r\n\r\n\r\n\r\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"known_not_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-111497"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0009"
]
},
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. If UMC authentication is enabled, block requests that use Brotli compression: in IIS Manager, select the Default Web Site, open \"Request Filtering\" \u003e \"Rules\", click \"Add Filtering Rule\", enter Name \"CVE-2026-111497\", Scan Headers \"Content-Encoding\" and Deny Strings \"br\", then click OK.",
"product_ids": [
"CSAFPID-0015"
]
},
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. In IIS Manager, select the Default Web Site, open \"Request Filtering\" \u003e \"Rules\", click \"Add Filtering Rule\", enter Name \"CVE-2026-111497\", Scan Headers \"Content-Encoding\" and Deny Strings \"br\", then click OK.",
"product_ids": [
"CSAFPID-0016"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0003",
"CSAFPID-0007",
"CSAFPID-0009"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.20 P17.1 or later version",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/110007354/"
},
{
"category": "vendor_fix",
"details": "Update to V8.2 Update 5 or later version",
"product_ids": [
"CSAFPID-0004",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109976926/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
],
"threats": [
{
"category": "impact",
"details": "not shipped as part of the product",
"product_ids": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2026-111497"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour