FKIE_CVE-2026-120976
Vulnerability from fkie_nvd - Published: 2026-11-10 20:18 - Updated: 2026-11-12 19:24
Severity
Summary
On affected platforms running Arista EOS with IEEE 802.1X authentication and MACsec using dynamically derived keys, sensitive authentication information may be recorded in diagnostic data during a Smart Switch Upgrade (SSU).
An attacker with administrative access on the device who obtains the affected diagnostic data could recover sensitive authentication information. This could potentially compromise the confidentiality and integrity of traffic protected by MACsec on the affected link.
The vulnerability is only exposed during and after an SSU reload where an active 802.1X session used for MACsec is present.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"platforms": [
"7388-8D Series",
"7500R/R2 Series",
"7800/R3/R3A Series",
"722XPM and 720XPM Series",
"750X Series",
"7050X3/X4 Series",
"7170 Series",
"7289R3 Series",
"7500R3 Series",
"7800R4 Series"
],
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"lessThan": "4.32.0F",
"status": "affected",
"version": "4.22.0F",
"versionType": "custom"
},
{
"lessThan": "4.33.0F",
"status": "affected",
"version": "4.32.0F",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.33.9M",
"status": "affected",
"version": "4.33.0F",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.34.8M",
"status": "affected",
"version": "4.34.0F",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.35.6M",
"status": "affected",
"version": "4.35.0F",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.36.2F",
"status": "affected",
"version": "4.36.0F",
"versionType": "custom"
}
]
}
],
"source": "psirt@arista.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On affected platforms running Arista EOS with IEEE 802.1X authentication and MACsec using dynamically derived keys, sensitive authentication information may be recorded in diagnostic data during a Smart Switch Upgrade (SSU).\n\nAn attacker with administrative access on the device who obtains the affected diagnostic data could recover sensitive authentication information. This could potentially compromise the confidentiality and integrity of traffic protected by MACsec on the affected link.\n\nThe vulnerability is only exposed during and after an SSU reload where an active 802.1X session used for MACsec is present."
}
],
"id": "CVE-2026-120976",
"lastModified": "2026-11-12T19:24:37.847",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.2,
"source": "psirt@arista.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "psirt@arista.com",
"type": "Secondary"
}
]
},
"published": "2026-11-10T20:18:52.660",
"references": [
{
"source": "psirt@arista.com",
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/25038-security-advisory-0216"
}
],
"sourceIdentifier": "psirt@arista.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "psirt@arista.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…