FKIE_CVE-2020-15056

Vulnerability from fkie_nvd - Published: 2020-08-07 22:15 - Updated: 2026-06-17 02:55
Summary
TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to conduct persistent XSS attacks by leveraging administrative privileges to set a crafted server name.
Impacted products
Vendor Product Version
tp-link tl-ps310u_firmware *
tp-link tl-ps310u -

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cve@mitre.org"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tp-link:tl-ps310u_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDADF57-8CED-49F8-A065-5F1F7A544BA3",
              "versionEndExcluding": "2.079.000.t0210",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tp-link:tl-ps310u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14AEB924-22A0-4DC5-B153-AA64BA079E52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to conduct persistent XSS attacks by leveraging administrative privileges to set a crafted server name."
    },
    {
      "lang": "es",
      "value": "Los dispositivos TP-Link USB Network Server TL-PS310U versiones anteriores a 2.079.000.t0210, permiten a un atacante en la misma red conducir ataques de tipo XSS persistentes al aprovechar los privilegios administrativos para establecer un nombre de servidor dise\u00f1ado"
    }
  ],
  "id": "CVE-2020-15056",
  "lastModified": "2026-06-17T02:55:58.703",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 2.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 4.4,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-08-07T22:15:12.913",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link",
        "Third Party Advisory"
      ],
      "url": "https://research.hisolutions.com/2020/05/critical-vulnerabilites-in-multiple-usb-network-servers/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Third Party Advisory"
      ],
      "url": "https://research.hisolutions.com/2020/05/critical-vulnerabilites-in-multiple-usb-network-servers/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…