EUVD-2026-61828
European Vulnerability Database identifier assigned by ENISAReserved
2026-10-02 06:10
Assigner
ENISA
Alias of
a CVE record, shown under related vulnerabilities.
This identifier carries no description, severity or references of its own:
they belong to that CVE.
{
"assigner": "ENISA",
"date_reserved": "2026-10-02T06:10:18.586700+00:00",
"id": "EUVD-2026-61828"
}
CVE-2018-4839 (GCVE-0-2018-4839)
Vulnerability from cvelistv5 – Published: 2018-03-08 17:00 – Updated: 2024-08-05 05:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
Severity
No CVSS data available.
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
Impacted products
15 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | DIGSI 4 |
Affected:
All versions < V4.92
|
|
| Siemens | EN100 Ethernet module DNP3 variant |
Affected:
All versions < V1.05.00
|
|
| Siemens | EN100 Ethernet module IEC 104 variant |
Affected:
All versions
|
|
| Siemens | EN100 Ethernet module IEC 61850 variant |
Affected:
All versions < V4.30
|
|
| Siemens | EN100 Ethernet module Modbus TCP variant |
Affected:
All versions
|
|
| Siemens | EN100 Ethernet module PROFINET IO variant |
Affected:
All versions
|
|
| Siemens | Other SIPROTEC 4 relays |
Affected:
All versions
|
|
| Siemens | Other SIPROTEC Compact relays |
Affected:
All versions
|
|
| Siemens | SIPROTEC 4 7SD80 |
Affected:
All versions < V4.70
|
|
| Siemens | SIPROTEC 4 7SJ61 |
Affected:
All versions < V4.96
|
|
| Siemens | SIPROTEC 4 7SJ62 |
Affected:
All versions < V4.96
|
|
| Siemens | SIPROTEC 4 7SJ64 |
Affected:
All versions < V4.96
|
|
| Siemens | SIPROTEC 4 7SJ66 |
Affected:
All versions < V4.30
|
|
| Siemens | SIPROTEC Compact 7SJ80 |
Affected:
All versions < V4.77
|
|
| Siemens | SIPROTEC Compact 7SK80 |
Affected:
All versions < V4.77
|
Date Public
2018-03-08 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:18:26.659Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIGSI 4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.92"
}
]
},
{
"product": "EN100 Ethernet module DNP3 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.05.00"
}
]
},
{
"product": "EN100 Ethernet module IEC 104 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module IEC 61850 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.30"
}
]
},
{
"product": "EN100 Ethernet module Modbus TCP variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module PROFINET IO variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Other SIPROTEC 4 relays",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Other SIPROTEC Compact relays",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIPROTEC 4 7SD80",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.70"
}
]
},
{
"product": "SIPROTEC 4 7SJ61",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.96"
}
]
},
{
"product": "SIPROTEC 4 7SJ62",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.96"
}
]
},
{
"product": "SIPROTEC 4 7SJ64",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.96"
}
]
},
{
"product": "SIPROTEC 4 7SJ66",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.30"
}
]
},
{
"product": "SIPROTEC Compact 7SJ80",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.77"
}
]
},
{
"product": "SIPROTEC Compact 7SK80",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.77"
}
]
}
],
"datePublic": "2018-03-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-13T11:02:46.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-4839",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIGSI 4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.92"
}
]
}
},
{
"product_name": "EN100 Ethernet module DNP3 variant",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.05.00"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC 104 variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC 61850 variant",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.30"
}
]
}
},
{
"product_name": "EN100 Ethernet module Modbus TCP variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module PROFINET IO variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Other SIPROTEC 4 relays",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Other SIPROTEC Compact relays",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIPROTEC 4 7SD80",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.70"
}
]
}
},
{
"product_name": "SIPROTEC 4 7SJ61",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.96"
}
]
}
},
{
"product_name": "SIPROTEC 4 7SJ62",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.96"
}
]
}
},
{
"product_name": "SIPROTEC 4 7SJ64",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.96"
}
]
}
},
{
"product_name": "SIPROTEC 4 7SJ66",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.30"
}
]
}
},
{
"product_name": "SIPROTEC Compact 7SJ80",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.77"
}
]
}
},
{
"product_name": "SIPROTEC Compact 7SK80",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.77"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-4839",
"datePublished": "2018-03-08T17:00:00.000Z",
"dateReserved": "2018-01-02T00:00:00.000Z",
"dateUpdated": "2024-08-05T05:18:26.659Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…
Loading…