CVE-2020-5953 (GCVE-0-2020-5953)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:00 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/products | x_refsource_MISC |
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:23.190Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/products"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0005/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:02.148Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/products"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0005/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-5953",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/products",
"refsource": "MISC",
"url": "https://www.insyde.com/products"
},
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0005/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0005/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-5953",
"datePublished": "2022-02-03T01:00:57.000Z",
"dateReserved": "2020-01-06T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:02.148Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…
Loading…