CVE-2026-19809 (GCVE-0-2026-19809)

Vulnerability from cvelistv5 – Published: 2026-11-12 15:19 – Updated: 2026-11-12 15:19
VLAI
Title
Kernel stack information disclosure in the charger_get_prop() system call handler
Summary
The user-mode system call verifier z_vrfy_charger_get_prop() in drivers/charger/charger_handlers.c declares an uninitialized union charger_propval k_val on the kernel (privileged) stack, passes it to the charger driver back end via z_impl_charger_get_prop(), and then copies the full sizeof(union charger_propval) back into the calling user thread's buffer with k_usermode_to_copy(). That discloses kernel stack contents on two paths: On error. The copy-out ignores the driver's return code. In-tree back ends return an error without writing through the value pointer for properties they do not implement: charger_gpio_get_prop() returns -ENOTSUP unconditionally, and bq24190_get_prop() has a default: return -ENOTSUP; arm that never touches val. The whole union is then stack residue. On success. A back end writes only the one union member the requested property selects (for example sbs_charger.c writes the one-byte val->present for CHARGER_PROP_PRESENT and returns 0), yet the handler still copies the whole union, so every byte beyond that member is uninitialized. The handler is compiled only when CONFIG_USERSPACE=y and is reachable by any user-mode thread that has been granted access to a charger device object. K_SYSCALL_DRIVER_CHARGER() validates only the device object and its API pointer, not the property identifier, so an unprivileged thread can choose prop freely: an unimplemented property forces the error path, a narrow one the success path, and the call can be repeated at will. Each call discloses up to the size of the union (12 bytes on a 32-bit target, 16 bytes on 64-bit targets where the function-pointer members widen it) of supervisor-stack memory. The bytes are residue of earlier kernel-side frames on the thread's privileged stack and can contain kernel object addresses and saved return addresses, which an unprivileged thread cannot otherwise observe and which help defeat address-layout assumptions when exploiting a separate memory-safety defect. There is no integrity or availability impact. Two commits fix it, and both are needed. 5054384e983c skips the copy-out when the back end reports an error. c31cac727d02 zeroes the union before the driver call, so the bytes copied out on success are driver-written data or zeros. A tree carrying only the first still leaks on every successful call.
CWE
Impacted products
Vendor Product Version
zephyrproject zephyr Affected: 3.5.0 , < 4.3.2 (semver)
Affected: 4.4.0 , < 4.5.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "collectionURL": "https://github.com/zephyrproject-rtos/zephyr",
          "defaultStatus": "unaffected",
          "packageName": "zephyr",
          "product": "zephyr",
          "programFiles": [
            "drivers/charger/charger_handlers.c"
          ],
          "programRoutines": [
            {
              "name": "z_vrfy_charger_get_prop"
            }
          ],
          "vendor": "zephyrproject",
          "versions": [
            {
              "lessThan": "4.3.2",
              "status": "affected",
              "version": "3.5.0",
              "versionType": "semver"
            },
            {
              "lessThan": "4.5.0",
              "status": "affected",
              "version": "4.4.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The user-mode system call verifier z_vrfy_charger_get_prop() in drivers/charger/charger_handlers.c declares an uninitialized union charger_propval k_val on the kernel (privileged) stack, passes it to the charger driver back end via z_impl_charger_get_prop(), and then copies the full sizeof(union charger_propval) back into the calling user thread\u0027s buffer with k_usermode_to_copy(). That discloses kernel stack contents on two paths:\n\nOn error. The copy-out ignores the driver\u0027s return code. In-tree back ends return an error without writing through the value pointer for properties they do not implement: charger_gpio_get_prop() returns -ENOTSUP unconditionally, and bq24190_get_prop() has a default: return -ENOTSUP; arm that never touches val. The whole union is then stack residue.\nOn success. A back end writes only the one union member the requested property selects (for example sbs_charger.c writes the one-byte val-\u003epresent for CHARGER_PROP_PRESENT and returns 0), yet the handler still copies the whole union, so every byte beyond that member is uninitialized.\n\nThe handler is compiled only when CONFIG_USERSPACE=y and is reachable by any user-mode thread that has been granted access to a charger device object. K_SYSCALL_DRIVER_CHARGER() validates only the device object and its API pointer, not the property identifier, so an unprivileged thread can choose prop freely: an unimplemented property forces the error path, a narrow one the success path, and the call can be repeated at will.\n\nEach call discloses up to the size of the union (12 bytes on a 32-bit target, 16 bytes on 64-bit targets where the function-pointer members widen it) of supervisor-stack memory. The bytes are residue of earlier kernel-side frames on the thread\u0027s privileged stack and can contain kernel object addresses and saved return addresses, which an unprivileged thread cannot otherwise observe and which help defeat address-layout assumptions when exploiting a separate memory-safety defect. There is no integrity or availability impact.\n\nTwo commits fix it, and both are needed. 5054384e983c skips the copy-out when the back end reports an error. c31cac727d02 zeroes the union before the driver call, so the bytes copied out on success are driver-written data or zeros. A tree carrying only the first still leaks on every successful call."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-252",
              "description": "info-leak",
              "lang": "en",
              "type": "CWE"
            },
            {
              "cweId": "CWE-908",
              "description": "info-leak",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-11-12T15:19:22.205Z",
        "orgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
        "shortName": "zephyr"
      },
      "references": [
        {
          "name": "Fix commit 5054384e983c",
          "tags": [
            "patch"
          ],
          "url": "https://github.com/zephyrproject-rtos/zephyr/commit/5054384e983c105b90d704272abcd479486ae3a2"
        },
        {
          "name": "Fix commit c31cac727d02",
          "tags": [
            "patch"
          ],
          "url": "https://github.com/zephyrproject-rtos/zephyr/commit/c31cac727d029f273a67f65941985696f1882867"
        },
        {
          "name": "GHSA-rghm-r3c9-92qc",
          "url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-rghm-r3c9-92qc"
        }
      ],
      "title": "Kernel stack information disclosure in the charger_get_prop() system call handler",
      "x_generator": {
        "engine": "cvelib 1.8.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
    "assignerShortName": "zephyr",
    "cveId": "CVE-2026-19809",
    "datePublished": "2026-11-12T15:19:22.205Z",
    "dateReserved": "2026-08-13T23:10:06.796Z",
    "dateUpdated": "2026-11-12T15:19:22.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-19809",
      "date": "2026-11-16",
      "epss": "0.00109",
      "percentile": "0.01285"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "collectionURL": "https://github.com/zephyrproject-rtos/zephyr",
                "defaultStatus": "unaffected",
                "packageName": "zephyr",
                "product": "zephyr",
                "programFiles": [
                  "drivers/charger/charger_handlers.c"
                ],
                "programRoutines": [
                  {
                    "name": "z_vrfy_charger_get_prop"
                  }
                ],
                "vendor": "zephyrproject",
                "versions": [
                  {
                    "lessThan": "4.3.2",
                    "status": "affected",
                    "version": "3.5.0",
                    "versionType": "semver"
                  },
                  {
                    "lessThan": "4.5.0",
                    "status": "affected",
                    "version": "4.4.0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "vulnerabilities@zephyrproject.org"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The user-mode system call verifier z_vrfy_charger_get_prop() in drivers/charger/charger_handlers.c declares an uninitialized union charger_propval k_val on the kernel (privileged) stack, passes it to the charger driver back end via z_impl_charger_get_prop(), and then copies the full sizeof(union charger_propval) back into the calling user thread\u0027s buffer with k_usermode_to_copy(). That discloses kernel stack contents on two paths:\n\nOn error. The copy-out ignores the driver\u0027s return code. In-tree back ends return an error without writing through the value pointer for properties they do not implement: charger_gpio_get_prop() returns -ENOTSUP unconditionally, and bq24190_get_prop() has a default: return -ENOTSUP; arm that never touches val. The whole union is then stack residue.\nOn success. A back end writes only the one union member the requested property selects (for example sbs_charger.c writes the one-byte val-\u003epresent for CHARGER_PROP_PRESENT and returns 0), yet the handler still copies the whole union, so every byte beyond that member is uninitialized.\n\nThe handler is compiled only when CONFIG_USERSPACE=y and is reachable by any user-mode thread that has been granted access to a charger device object. K_SYSCALL_DRIVER_CHARGER() validates only the device object and its API pointer, not the property identifier, so an unprivileged thread can choose prop freely: an unimplemented property forces the error path, a narrow one the success path, and the call can be repeated at will.\n\nEach call discloses up to the size of the union (12 bytes on a 32-bit target, 16 bytes on 64-bit targets where the function-pointer members widen it) of supervisor-stack memory. The bytes are residue of earlier kernel-side frames on the thread\u0027s privileged stack and can contain kernel object addresses and saved return addresses, which an unprivileged thread cannot otherwise observe and which help defeat address-layout assumptions when exploiting a separate memory-safety defect. There is no integrity or availability impact.\n\nTwo commits fix it, and both are needed. 5054384e983c skips the copy-out when the back end reports an error. c31cac727d02 zeroes the union before the driver call, so the bytes copied out on success are driver-written data or zeros. A tree carrying only the first still leaks on every successful call."
          }
        ],
        "id": "CVE-2026-19809",
        "lastModified": "2026-11-12T16:19:09.000",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 1.4,
              "source": "vulnerabilities@zephyrproject.org",
              "type": "Secondary"
            }
          ]
        },
        "published": "2026-11-12T16:19:08.810",
        "references": [
          {
            "source": "vulnerabilities@zephyrproject.org",
            "url": "https://github.com/zephyrproject-rtos/zephyr/commit/5054384e983c105b90d704272abcd479486ae3a2"
          },
          {
            "source": "vulnerabilities@zephyrproject.org",
            "url": "https://github.com/zephyrproject-rtos/zephyr/commit/c31cac727d029f273a67f65941985696f1882867"
          },
          {
            "source": "vulnerabilities@zephyrproject.org",
            "url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-rghm-r3c9-92qc"
          }
        ],
        "sourceIdentifier": "vulnerabilities@zephyrproject.org",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-252"
              },
              {
                "lang": "en",
                "value": "CWE-908"
              }
            ],
            "source": "vulnerabilities@zephyrproject.org",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…