CVE-2026-112172 (GCVE-0-2026-112172)

Vulnerability from cvelistv5 – Published: 2026-11-09 11:38 – Updated: 2026-11-12 15:49
VLAI
Title
Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure
Summary
CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-12 15:48 UTC
CWE
  • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
References
Impacted products
Vendor Product Version
CompuGroup Medical XDent Affected: 0 , < 4.4.0 (semver)
Create a notification for this product.
CompuGroup Medical XMedical Affected: 0 , < 4.4.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-112172",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-11-12T15:48:11.664289Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-11-12T15:49:33.068Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "XDent",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThan": "4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "XMedical",
          "vendor": "CompuGroup Medical",
          "versions": [
            {
              "lessThan": "4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marco Sala"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "CSIRT-IT"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "ApoCert srl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
            }
          ],
          "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "UNREPORTED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-11-09T11:45:11.226Z",
        "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "shortName": "ENISA"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
        }
      ],
      "title": "Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
    "assignerShortName": "ENISA",
    "cveId": "CVE-2026-112172",
    "datePublished": "2026-11-09T11:38:18.744Z",
    "dateReserved": "2026-10-19T08:06:39.208Z",
    "dateUpdated": "2026-11-12T15:49:33.068Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-112172",
      "date": "2026-11-16",
      "epss": "0.00382",
      "percentile": "0.32751"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "XDent",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThan": "4.4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "XMedical",
                "vendor": "CompuGroup Medical",
                "versions": [
                  {
                    "lessThan": "4.4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
          }
        ],
        "id": "CVE-2026-112172",
        "lastModified": "2026-11-12T20:07:11.090",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "UNREPORTED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-112172",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-11-12T15:48:11.664289Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-11-09T12:16:35.170",
        "references": [
          {
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
          },
          {
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
          }
        ],
        "sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-112172",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-12T15:48:11.664289Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-12T15:48:32.229Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "XDent",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "XMedical",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marco Sala"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CSIRT-IT"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "ApoCert srl"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
                }
              ],
              "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-09T11:45:11.226Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
            }
          ],
          "title": "Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-112172",
        "datePublished": "2026-11-09T11:38:18.744Z",
        "dateReserved": "2026-10-19T08:06:39.208Z",
        "dateUpdated": "2026-11-12T15:49:33.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…