CVE-2025-62863 (GCVE-0-2025-62863)

Vulnerability from cvelistv5 – Published: 2025-12-16 00:00 – Updated: 2025-12-17 14:30
VLAI
Summary
Ampere AmpereOne AC03 devices before 3.5.9.3, AmpereOne AC04 devices before 4.4.5.2, and AmpereOne M devices before 5.4.5.1 allow an incorrectly formed SMC call to UEFI-MM PCIe driver that could result in an out-of-bounds write within PCIe driver’s S-EL0 address space.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-12-17 14:28 UTC
CWE
  • n/a
  • CWE-787 - Out-of-bounds Write
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-62863",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-17T14:28:39.515420Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-17T14:30:24.767Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Ampere AmpereOne AC03 devices before 3.5.9.3, AmpereOne AC04 devices before 4.4.5.2, and AmpereOne M devices before 5.4.5.1 allow an incorrectly formed SMC call to UEFI-MM PCIe driver that could result in an out-of-bounds write within PCIe driver\u2019s S-EL0 address space."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-16T17:09:18.409Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://amperecomputing.com/products/product-security"
        },
        {
          "url": "https://amperecomputing.com/products/security-bulletins/amp-sb-0007"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-62863",
    "datePublished": "2025-12-16T00:00:00.000Z",
    "dateReserved": "2025-10-24T00:00:00.000Z",
    "dateUpdated": "2025-12-17T14:30:24.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-62863",
      "date": "2026-10-22",
      "epss": "0.00365",
      "percentile": "0.29194"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a192-32m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A9523999-81AB-47DD-B8D5-A352FE3B1D5B",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a192-32m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2384E36F-8268-404E-80D6-C98E3EA1C299",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a192-26m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A13FFFC6-7355-4F15-B1AC-A1F8D71A4AD1",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a192-26m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F9EBCAD2-E1D0-40FC-8791-AD0F50EEBE50",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a160-28m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "54A0E3ED-F092-448D-8ACE-A0A16C4B451E",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a160-28m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1E5723F8-301B-49B1-8968-1337689146DE",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a144-33m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6996EFF6-6CF0-44B9-997F-A3C721D0CDA2",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a144-33m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "45C2645C-B01C-4070-A1D0-32D614028AD3",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a144-26m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "90C08FC4-2D5F-4E67-88AB-A82A1C0D60EC",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a144-26m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A1766FF3-1D99-4FED-AC42-E0954FCCBF0C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a96-36m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "753CE183-4807-4C99-8BD4-43B57C5A44D6",
                    "versionEndExcluding": "5.4.5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a96-36m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1E84F28F-985D-4A5F-9A4E-49B7A39F913E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a96-36x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "851C8C9F-5FFB-451D-95CC-75A8CDAEC59B",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a96-36x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2A293338-7B91-4536-BE77-7A1FE411DFBC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a128-34x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D2A240BF-86B5-4681-9347-E871369AE3AA",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a128-34x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2759F0C5-2524-4A36-AC06-B4A9125E1189",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a144-24x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A60D15B1-7711-4419-B6ED-A0C8D61DC991",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a144-24x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8A57F1D6-F2CA-4A61-8F2F-C756AD4A11EE",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a144-27x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8685D55B-0AB3-469D-92C4-F98449084DE4",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a144-27x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E61BD8B1-4DCF-4F35-BF07-C2E44E8E7A7A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a160-28x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "47D79145-0EE4-45CC-8E51-14D38ECEA119",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a160-28x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8488DA56-F3F6-4856-AAC9-413C8393612E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a192-26x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "97DB4E54-13CA-4EA8-9CC6-E5AA0E6EB048",
                    "versionEndExcluding": "4.4.5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a192-26x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9744AF49-0DAC-4D77-8C97-358D35AE8CB5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a192-26x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5E6D74E9-A670-4E89-81CD-B71920B36524",
                    "versionEndExcluding": "3.5.9.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a192-26x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9744AF49-0DAC-4D77-8C97-358D35AE8CB5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:amperecomputing:ampereone_a192-32x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B63B45BE-CD33-4552-9F11-44D454D79C40",
                    "versionEndExcluding": "3.5.9.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:amperecomputing:ampereone_a192-32x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "02E036AB-D815-44CA-ABEF-315379550223",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Ampere AmpereOne AC03 devices before 3.5.9.3, AmpereOne AC04 devices before 4.4.5.2, and AmpereOne M devices before 5.4.5.1 allow an incorrectly formed SMC call to UEFI-MM PCIe driver that could result in an out-of-bounds write within PCIe driver\u2019s S-EL0 address space."
          },
          {
            "lang": "es",
            "value": "Los dispositivos Ampere AmpereOne AC03 anteriores a la versi\u00f3n 3.5.9.3, los dispositivos AmpereOne AC04 anteriores a la versi\u00f3n 4.4.5.2 y los dispositivos AmpereOne M anteriores a la versi\u00f3n 5.4.5.1 permiten una llamada SMC incorrectamente formada al controlador PCIe UEFI-MM que podr\u00eda resultar en una escritura fuera de l\u00edmites dentro del espacio de direcciones S-EL0 del controlador PCIe."
          }
        ],
        "id": "CVE-2025-62863",
        "lastModified": "2026-10-13T11:10:00.203",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-62863",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-17T14:28:39.515420Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-12-16T18:16:13.493",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://amperecomputing.com/products/product-security"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://amperecomputing.com/products/security-bulletins/amp-sb-0007"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-62863",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-17T14:28:39.515420Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-17T14:30:10.231Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Ampere AmpereOne AC03 devices before 3.5.9.3, AmpereOne AC04 devices before 4.4.5.2, and AmpereOne M devices before 5.4.5.1 allow an incorrectly formed SMC call to UEFI-MM PCIe driver that could result in an out-of-bounds write within PCIe driver\u2019s S-EL0 address space."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-16T17:09:18.409Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://amperecomputing.com/products/product-security"
            },
            {
              "url": "https://amperecomputing.com/products/security-bulletins/amp-sb-0007"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-62863",
        "datePublished": "2025-12-16T00:00:00.000Z",
        "dateReserved": "2025-10-24T00:00:00.000Z",
        "dateUpdated": "2025-12-17T14:30:24.767Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…