CVE-2025-14038 (GCVE-0-2025-14038)

Vulnerability from cvelistv5 – Published: 2025-12-15 18:02 – Updated: 2025-12-15 19:01
VLAI
Summary
EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible. The flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service. All versions of Hybrid Manager - LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager - Innovation should be upgraded to 2025.12.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-12-15 19:01 UTC
CWE
  • CWE-862 - Missing Authorization
  • CWE-306 - Missing Authentication for Critical Function
Impacted products
Vendor Product Version
EnterpriseDB Hybrid Manager - LTS Affected: 1.3 , < 1.3.3 (semver)
Affected: 1.2 (semver)
Create a notification for this product.
EnterpriseDB Hybrid Manager - Innovation Affected: 2025 , < 2025.12 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14038",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-15T19:01:41.820963Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-15T19:01:52.793Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Hybrid Manager - LTS",
          "vendor": "EnterpriseDB",
          "versions": [
            {
              "lessThan": "1.3.3",
              "status": "affected",
              "version": "1.3",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "1.2",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Hybrid Manager - Innovation",
          "vendor": "EnterpriseDB",
          "versions": [
            {
              "lessThan": "2025.12",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible.\nThe flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service.\nAll versions of Hybrid Manager - LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager - Innovation should be upgraded to 2025.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862 Missing Authorization",
              "lang": "en",
              "type": "CWE"
            },
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-15T18:02:01.294Z",
        "orgId": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
        "shortName": "EDB"
      },
      "references": [
        {
          "url": "https://www.enterprisedb.com/docs/security/advisories/cve202514038/"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
    "assignerShortName": "EDB",
    "cveId": "CVE-2025-14038",
    "datePublished": "2025-12-15T18:02:01.294Z",
    "dateReserved": "2025-12-04T15:37:36.286Z",
    "dateUpdated": "2025-12-15T19:01:52.793Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-14038",
      "date": "2026-11-16",
      "epss": "0.00247",
      "percentile": "0.16086"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "product": "Hybrid Manager - LTS",
                "vendor": "EnterpriseDB",
                "versions": [
                  {
                    "lessThan": "1.3.3",
                    "status": "affected",
                    "version": "1.3",
                    "versionType": "semver"
                  },
                  {
                    "status": "affected",
                    "version": "1.2",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "affected",
                "product": "Hybrid Manager - Innovation",
                "vendor": "EnterpriseDB",
                "versions": [
                  {
                    "lessThan": "2025.12",
                    "status": "affected",
                    "version": "2025",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "20be33e2-bf35-4d13-8fad-18bd2f3e3659"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:enterprisedb:hybrid_manager:*:*:*:*:lts:*:*:*",
                    "matchCriteriaId": "6F71218D-EC98-4F63-9BDD-29538E045DDE",
                    "versionEndExcluding": "1.3.3",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:enterprisedb:hybrid_manager:*:*:*:*:innovation:*:*:*",
                    "matchCriteriaId": "01F426CB-3CB6-4906-8173-7A6D41275D8B",
                    "versionEndExcluding": "2025.12.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible.\nThe flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service.\nAll versions of Hybrid Manager - LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager - Innovation should be upgraded to 2025.12."
          },
          {
            "lang": "es",
            "value": "EDB Hybrid Manager contiene una falla que permite a un atacante no autenticado acceder directamente a ciertos puntos finales gRPC. Esto podr\u00eda permitir a un atacante leer datos potencialmente sensibles o posiblemente causar una denegaci\u00f3n de servicio al escribir datos malformados en ciertos puntos finales gRPC. Esta falla ha sido remediada en EDB Hybrid Manager 1.3.3, y los clientes deber\u00edan considerar actualizar a la versi\u00f3n 1.3.3 lo antes posible.\nLa falla se debe a una mala configuraci\u00f3n en el Istio Gateway, que gestiona la autenticaci\u00f3n y la autorizaci\u00f3n para los puntos finales afectados. La pol\u00edtica de seguridad se basa en una definici\u00f3n expl\u00edcita de los permisos requeridos en la configuraci\u00f3n del Istio Gateway, y los puntos finales afectados no estaban definidos en la configuraci\u00f3n. Esto permiti\u00f3 que las solicitudes eludieran tanto la autenticaci\u00f3n como la autorizaci\u00f3n dentro de un servicio de Hybrid Manager.\nTodas las versiones de Hybrid Manager - LTS deber\u00edan actualizarse a la versi\u00f3n 1.3.3, y todas las versiones de Hybrid Manager - Innovation deber\u00edan actualizarse a la versi\u00f3n 2025.12."
          }
        ],
        "id": "CVE-2025-14038",
        "lastModified": "2026-10-07T19:10:00.160",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.2,
              "impactScore": 4.7,
              "source": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-14038",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-15T19:01:41.820963Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-12-15T18:15:47.100",
        "references": [
          {
            "source": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.enterprisedb.com/docs/security/advisories/cve202514038/"
          }
        ],
        "sourceIdentifier": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              },
              {
                "lang": "en",
                "value": "CWE-862"
              }
            ],
            "source": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14038",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-15T19:01:41.820963Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-15T19:01:45.511Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Hybrid Manager - LTS",
              "vendor": "EnterpriseDB",
              "versions": [
                {
                  "lessThan": "1.3.3",
                  "status": "affected",
                  "version": "1.3",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "1.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "Hybrid Manager - Innovation",
              "vendor": "EnterpriseDB",
              "versions": [
                {
                  "lessThan": "2025.12",
                  "status": "affected",
                  "version": "2025",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "EDB Hybrid Manager contains a flaw that allows an unauthenticated attacker to directly access certain gRPC endpoints. This could allow an attacker to read potentially sensitive data or possibly cause a denial-of-service by writing malformed data to certain gRPC endpoints. This flaw has been remediated in EDB Hybrid Manager 1.3.3, and customers should consider upgrading to 1.3.3 as soon as possible.\nThe flaw is due to a misconfiguration in the Istio Gateway, which manages authentication and authorization for the affected endpoints. The security policy relies on an explicit definition of required permissions in the Istio Gateway configuration, and the affected endpoints were not defined in the configuration. This allowed requests to bypass both authentication and authorization within a Hybrid Manager service.\nAll versions of Hybrid Manager - LTS should be upgraded to 1.3.3, and all versions of Hybrid Manager - Innovation should be upgraded to 2025.12."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                },
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-15T18:02:01.294Z",
            "orgId": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
            "shortName": "EDB"
          },
          "references": [
            {
              "url": "https://www.enterprisedb.com/docs/security/advisories/cve202514038/"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20be33e2-bf35-4d13-8fad-18bd2f3e3659",
        "assignerShortName": "EDB",
        "cveId": "CVE-2025-14038",
        "datePublished": "2025-12-15T18:02:01.294Z",
        "dateReserved": "2025-12-04T15:37:36.286Z",
        "dateUpdated": "2025-12-15T19:01:52.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…