CVE-2024-5680 (GCVE-0-2024-5680)

Vulnerability from cvelistv5 – Published: 2024-07-11 08:25 – Updated: 2024-08-01 21:18
VLAI
Summary
CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-11 14:11 UTC
CWE
  • CWE-129 - Improper Validation of Array Index
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5680",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T14:11:30.265135Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T14:11:39.357Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.841Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Foxboro DCS Core Control Services",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 9.8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nCWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver.\n\n\n\n"
            }
          ],
          "value": "CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-129",
              "description": "CWE-129 Improper Validation of Array Index",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-11T08:25:45.578Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5680",
    "datePublished": "2024-07-11T08:25:45.578Z",
    "dateReserved": "2024-06-06T12:06:41.878Z",
    "dateUpdated": "2024-08-01T21:18:06.841Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-5680",
      "date": "2026-10-07",
      "epss": "0.00146",
      "percentile": "0.03361"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "EcoStruxure Foxboro DCS Core Control Services",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "status": "affected",
                    "version": "Versions 9.8 and prior"
                  }
                ]
              }
            ],
            "source": "cybersecurity@se.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_foxboro_dcs_control_core_services:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AB752A3F-D5CE-4AFC-82D7-F0E3D8805DA5",
                    "versionEndIncluding": "9.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver."
          },
          {
            "lang": "es",
            "value": "CWE-129: Existe una vulnerabilidad de validaci\u00f3n inadecuada del \u00edndice de matriz que podr\u00eda causar denegaci\u00f3n de servicio local cuando un actor malicioso con acceso de usuario local crea un script/programa usando una llamada IOCTL en el controlador Foxboro.sys."
          }
        ],
        "id": "CVE-2024-5680",
        "lastModified": "2026-06-17T08:16:25.310",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.2,
              "source": "cybersecurity@se.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-5680",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T14:11:30.265135Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-07-11T09:15:03.923",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-129"
              }
            ],
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:18:06.841Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5680",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-11T14:11:30.265135Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-11T14:11:35.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Foxboro DCS Core Control Services",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 9.8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\nCWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver.\n\n\n\n"
                }
              ],
              "value": "CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-129",
                  "description": "CWE-129 Improper Validation of Array Index",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-11T08:25:45.578Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-5680",
        "datePublished": "2024-07-11T08:25:45.578Z",
        "dateReserved": "2024-06-06T12:06:41.878Z",
        "dateUpdated": "2024-08-01T21:18:06.841Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…