CVE-2024-29177 (GCVE-0-2024-29177)

Vulnerability from cvelistv5 – Published: 2024-06-26 02:46 – Updated: 2024-08-02 01:10
VLAI
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-26 19:05 UTC
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Date Public
2024-06-24 06:30
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29177",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T19:05:17.020326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:05:23.225Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:46:55.073Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29177",
    "datePublished": "2024-06-26T02:46:55.073Z",
    "dateReserved": "2024-03-18T08:44:18.924Z",
    "dateUpdated": "2024-08-02T01:10:54.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-29177",
      "date": "2026-10-10",
      "epss": "0.00296",
      "percentile": "0.20478"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "PowerProtect DD",
                "vendor": "Dell",
                "versions": [
                  {
                    "lessThanOrEqual": "7.13",
                    "status": "affected",
                    "version": "7.0",
                    "versionType": "semver"
                  },
                  {
                    "lessThan": "2.7.7",
                    "status": "affected",
                    "version": "N/A",
                    "versionType": "semver"
                  },
                  {
                    "lessThan": "5.16.0.0",
                    "status": "affected",
                    "version": "N/A",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "7.13",
                    "status": "affected",
                    "version": "7.8",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "security_alert@emc.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C6A0B6C8-491A-46F2-A330-15000DE501BA",
                    "versionEndExcluding": "7.7.5.40",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "28F4339F-F4B0-479A-B300-ADB987171B31",
                    "versionEndExcluding": "7.10.1.30",
                    "versionStartIncluding": "7.8.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8EF3066F-F378-4AA6-B50C-B33C22C57492",
                    "versionEndExcluding": "7.13.1.0",
                    "versionStartIncluding": "7.11.0.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
          },
          {
            "lang": "es",
            "value": "Dell PowerProtect DD, versiones anteriores a 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contienen una divulgaci\u00f3n de vulnerabilidad de informaci\u00f3n confidencial temporal. Un atacante remoto con privilegios elevados podr\u00eda explotar esta vulnerabilidad, lo que llevar\u00eda a la reutilizaci\u00f3n de la informaci\u00f3n divulgada para obtener acceso no autorizado al informe de la aplicaci\u00f3n."
          }
        ],
        "id": "CVE-2024-29177",
        "lastModified": "2026-06-17T07:22:34.057",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 1.4,
              "source": "security_alert@emc.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 1.4,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-29177",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T19:05:17.020326Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-06-26T03:15:10.767",
        "references": [
          {
            "source": "security_alert@emc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sourceIdentifier": "security_alert@emc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-532"
              }
            ],
            "source": "security_alert@emc.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:10:54.086Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-29177",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-26T19:05:17.020326Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-26T19:05:20.645Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect DD",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "7.13",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "2.7.7",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.16.0.0",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "7.13",
                  "status": "affected",
                  "version": "7.8",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2024-06-24T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
                }
              ],
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532: Insertion of Sensitive Information into Log File",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T02:46:55.073Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-29177",
        "datePublished": "2024-06-26T02:46:55.073Z",
        "dateReserved": "2024-03-18T08:44:18.924Z",
        "dateUpdated": "2024-08-02T01:10:54.086Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…