CVE-2023-24587 (GCVE-0-2023-24587)
Vulnerability from cvelistv5 – Published: 2023-11-14 19:04 – Updated: 2024-10-11 18:07
VLAI
EPSS
VEX
Summary
Insufficient control flow management in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable denial of service via local access.
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 17:51 UTC
CWE
- denial of service
- CWE-691 - Insufficient control flow management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Optane(TM) SSD products |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:03:18.992Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-24587",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:51:49.878192Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:07:34.507Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Optane(TM) SSD products",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en"
},
{
"cweId": "CWE-691",
"description": "Insufficient control flow management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:55.135Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-24587",
"datePublished": "2023-11-14T19:04:55.135Z",
"dateReserved": "2023-03-08T04:00:03.672Z",
"dateUpdated": "2024-10-11T18:07:34.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-24587",
"date": "2026-10-02",
"epss": "0.00182",
"percentile": "0.07079"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Optane(TM) SSD products",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"source": "secure@intel.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:optane_memory_h20_with_solid_state_storage_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FA3AE360-6625-4682-9E17-32BCEE976552",
"versionEndExcluding": "u4110553-g004",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:optane_memory_h20_with_solid_state_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00EFD6D0-2B8B-4450-A073-C6121264C94F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:optane_ssd_900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4E6363E3-64FC-4D8C-9779-B140AC0F9FE0",
"versionEndExcluding": "e2010650",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:optane_ssd_900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5AFC9CF7-581F-4B2D-B93C-3D7E3C136F4C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:optane_ssd_dc_p4800x_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D850E02-9A03-49A8-86F4-1D2B9203143D",
"versionEndExcluding": "e2010650",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:optane_ssd_dc_p4800x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE6F7C04-DA32-42BC-9C5F-651DF61E5589",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:optane_ssd_dc_p4801x_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A73436E5-92D0-4C3A-AF56-8551ABAF04F9",
"versionEndExcluding": "e2010650",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:optane_ssd_dc_p4801x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "15DAAAC1-DBA7-47BC-8796-B7C8B86DEFD0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:optane_ssd_905p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AFDD04FB-5301-42FF-AA92-FD0BC5CD26EE",
"versionEndExcluding": "e2010650",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:optane_ssd_905p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BD5595C-0047-441A-B398-8ACA421BB439",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable denial of service via local access."
},
{
"lang": "es",
"value": "La gesti\u00f3n insuficiente del flujo de control en el firmware para algunos productos Intel(R) Optane(TM) SSD puede permitir que un usuario privilegiado habilite potencialmente la denegaci\u00f3n de servicio a trav\u00e9s del acceso local."
}
],
"id": "CVE-2023-24587",
"lastModified": "2026-06-17T05:39:36.383",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.6,
"impactScore": 5.8,
"source": "secure@intel.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-24587",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:51:49.878192Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-11-14T19:15:18.297",
"references": [
{
"source": "secure@intel.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
}
],
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-691"
}
],
"source": "secure@intel.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:03:18.992Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-24587",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:51:49.878192Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T17:52:58.008Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Optane(TM) SSD products",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en"
},
{
"cweId": "CWE-691",
"description": "Insufficient control flow management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:55.135Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00758.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-24587",
"datePublished": "2023-11-14T19:04:55.135Z",
"dateReserved": "2023-03-08T04:00:03.672Z",
"dateUpdated": "2024-10-11T18:07:34.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.