CVE-2022-34452 (GCVE-0-2022-34452)

Vulnerability from cvelistv5 – Published: 2023-02-10 09:33 – Updated: 2025-03-24 18:35
VLAI
Summary
PowerPath Management Appliance with versions 3.3, 3.2*, 3.1 & 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 15:13 UTC
CWE
  • CWE-598 - Use of GET Request Method With Sensitive Query Strings
References
Impacted products
Vendor Product Version
Dell PowerPath Management Appliance Affected: 0 , ≤ 3.3, 3.2*, 3.1, 3.0* (custom)
Create a notification for this product.
Date Public
2022-11-15 06:30
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.200Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34452",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-24T15:13:46.502868Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-24T18:35:03.599Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerPath Management Appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "3.3, 3.2*, 3.1, 3.0*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-11-15T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026amp; 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-598",
              "description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-10T09:33:05.272Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34452",
    "datePublished": "2023-02-10T09:33:05.272Z",
    "dateReserved": "2022-06-23T18:55:17.133Z",
    "dateUpdated": "2025-03-24T18:35:03.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-34452",
      "date": "2026-10-06",
      "epss": "0.00435",
      "percentile": "0.35643"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "PowerPath Management Appliance",
                "vendor": "Dell",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3, 3.2*, 3.1, 3.0*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "security_alert@emc.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2FAF41A1-1C3A-43F0-9B38-705D0E12E34F",
                    "versionEndExcluding": "3.4",
                    "versionStartIncluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
          },
          {
            "lang": "es",
            "value": "PowerPath Management Appliance con versiones 3.3, 3.2*, 3.1 y 3.1. 3.0* contiene una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n confidencial. Un usuario administrador autenticado puede aprovechar el problema y ver informaci\u00f3n confidencial almacenada en los registros."
          }
        ],
        "id": "CVE-2022-34452",
        "lastModified": "2026-06-17T04:50:23.040",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 1.4,
              "source": "security_alert@emc.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 1.4,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-34452",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-24T15:13:46.502868Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-02-10T10:15:10.853",
        "references": [
          {
            "source": "security_alert@emc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sourceIdentifier": "security_alert@emc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-598"
              }
            ],
            "source": "security_alert@emc.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-668"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.200Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T15:13:46.502868Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T15:13:53.033Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "3.3, 3.2*, 3.1, 3.0*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026amp; 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-598",
                  "description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T09:33:05.272Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34452",
        "datePublished": "2023-02-10T09:33:05.272Z",
        "dateReserved": "2022-06-23T18:55:17.133Z",
        "dateUpdated": "2025-03-24T18:35:03.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…