CVE-2022-22792 (GCVE-0-2022-22792)

Vulnerability from cvelistv5 – Published: 2022-02-16 16:38 – Updated: 2024-09-17 02:48
VLAI
Title
MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters
Summary
MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters Attacker can navigate to specific url which will expose all the users and password in clear text. http://IP/MobiPlusWeb/Handlers/MainHandler.ashx?MethodName=GridData&GridName=Users
CWE
  • CWE-233 - Improper Handling of url Parameters
References
Impacted products
Vendor Product Version
MobiSoft eharmony Affected: MobiPlus , ≤ 1.0 (custom)
Create a notification for this product.
Date Public
2022-02-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:21:49.165Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/faq/cve_advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "eharmony",
          "vendor": "MobiSoft",
          "versions": [
            {
              "lessThanOrEqual": "1.0",
              "status": "affected",
              "version": "MobiPlus",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Dudu Moyal - Sophtix Security LTD"
        }
      ],
      "datePublic": "2022-02-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters Attacker can navigate to specific url which will expose all the users and password in clear text. http://IP/MobiPlusWeb/Handlers/MainHandler.ashx?MethodName=GridData\u0026amp;GridName=Users"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-233",
              "description": "CWE-233 Improper Handling of url Parameters",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-16T16:38:07.000Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.gov.il/en/departments/faq/cve_advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "An update was released which addresses the issue"
        }
      ],
      "source": {
        "advisory": "ILVN-2022-0013",
        "defect": [
          "ILVN-2022-0013"
        ],
        "discovery": "INTERNAL"
      },
      "title": "MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "INCD",
          "ASSIGNER": "cna@cyber.gov.il",
          "DATE_PUBLIC": "2022-02-01T12:26:00.000Z",
          "ID": "CVE-2022-22792",
          "STATE": "PUBLIC",
          "TITLE": "MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "eharmony",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "MobiPlus",
                            "version_value": "1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "MobiSoft"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Dudu Moyal - Sophtix Security LTD"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters Attacker can navigate to specific url which will expose all the users and password in clear text. http://IP/MobiPlusWeb/Handlers/MainHandler.ashx?MethodName=GridData\u0026amp;GridName=Users"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-233 Improper Handling of url Parameters"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.gov.il/en/departments/faq/cve_advisories",
              "refsource": "MISC",
              "url": "https://www.gov.il/en/departments/faq/cve_advisories"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "An update was released which addresses the issue"
          }
        ],
        "source": {
          "advisory": "ILVN-2022-0013",
          "defect": [
            "ILVN-2022-0013"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2022-22792",
    "datePublished": "2022-02-16T16:38:07.784Z",
    "dateReserved": "2022-01-07T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:48:02.992Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-22792",
      "date": "2026-10-04",
      "epss": "0.00592",
      "percentile": "0.46405"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "eharmony",
                "vendor": "MobiSoft",
                "versions": [
                  {
                    "lessThanOrEqual": "1.0",
                    "status": "affected",
                    "version": "MobiPlus",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cna@cyber.gov.il"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:mobisoft_-_mobiplus_project:mobisoft_-_mobiplus:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F1E89FF9-E34B-4FFC-B672-67145788CC62",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "MobiSoft - MobiPlus User Take Over and Improper Handling of url Parameters Attacker can navigate to specific url which will expose all the users and password in clear text. http://IP/MobiPlusWeb/Handlers/MainHandler.ashx?MethodName=GridData\u0026amp;GridName=Users"
          },
          {
            "lang": "es",
            "value": "MobiSoft - MobiPlus una Toma de posesi\u00f3n del usuario y manejo inapropiado de los par\u00e1metros de la url, El atacante puede navegar a una url espec\u00edfica que expondr\u00e1 todos los usuarios y la contrase\u00f1a en texto sin cifrar. http://IP/MobiPlusWeb/Handlers/MainHandler.ashx?MethodName=GridData\u0026amp;GridName=Users"
          }
        ],
        "id": "CVE-2022-22792",
        "lastModified": "2026-06-17T04:29:03.150",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 4.7,
              "source": "cna@cyber.gov.il",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2022-02-16T17:15:11.660",
        "references": [
          {
            "source": "cna@cyber.gov.il",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.gov.il/en/departments/faq/cve_advisories"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.gov.il/en/departments/faq/cve_advisories"
          }
        ],
        "sourceIdentifier": "cna@cyber.gov.il",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-233"
              }
            ],
            "source": "cna@cyber.gov.il",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-Other"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…