CVE-2018-0626 (GCVE-0-2018-0626)

Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 03:35
VLAI
Summary
Aterm WG1200HP firmware Ver1.0.31 and earlier allows attacker with administrator rights to execute arbitrary OS commands via sysCmd in formWsc parameter.
CWE
  • OS Command Injection
References
Impacted products
Vendor Product Version
NEC Corporation WG1200HP Affected: firmware Ver1.0.31 and earlier
Create a notification for this product.
Date Public
2019-01-09 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:35:47.771Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-011.html"
          },
          {
            "name": "JVN#00401783",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN00401783/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WG1200HP",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver1.0.31 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WG1200HP firmware Ver1.0.31 and earlier allows attacker with administrator rights to execute arbitrary OS commands via sysCmd in formWsc parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01.000Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-011.html"
        },
        {
          "name": "JVN#00401783",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN00401783/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-0626",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WG1200HP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware Ver1.0.31 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WG1200HP firmware Ver1.0.31 and earlier allows attacker with administrator rights to execute arbitrary OS commands via sysCmd in formWsc parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-011.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-011.html"
            },
            {
              "name": "JVN#00401783",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN00401783/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-0626",
    "datePublished": "2019-01-09T22:00:00.000Z",
    "dateReserved": "2017-11-27T00:00:00.000Z",
    "dateUpdated": "2024-08-05T03:35:47.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-0626",
      "date": "2026-10-01",
      "epss": "0.01399",
      "percentile": "0.71488"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "WG1200HP",
                "vendor": "NEC Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "firmware Ver1.0.31 and earlier"
                  }
                ]
              }
            ],
            "source": "vultures@jpcert.or.jp"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:nec:aterm_wg1200hp_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F76EB942-F1B9-4F1B-9237-B42BCF5BB8A5",
                    "versionEndIncluding": "1.0.31",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:nec:aterm_wg1200hp:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "44A32F85-959D-4671-BD16-7D6C12705A0C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Aterm WG1200HP firmware Ver1.0.31 and earlier allows attacker with administrator rights to execute arbitrary OS commands via sysCmd in formWsc parameter."
          },
          {
            "lang": "es",
            "value": "Aterm WG1200HP, con firmware Ver1.0.31 y anteriores, permite a los atacantes con permisos de administrador ejecutar comandos SO arbitrarios mediante sysCmd en el par\u00e1metro formWsc."
          }
        ],
        "id": "CVE-2018-0626",
        "lastModified": "2026-06-17T01:31:19.870",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-01-09T23:29:00.387",
        "references": [
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-011.html"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/en/jp/JVN00401783/index.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-011.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/en/jp/JVN00401783/index.html"
          }
        ],
        "sourceIdentifier": "vultures@jpcert.or.jp",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…