SEVD-2026-328-01

Vulnerability from csaf_se - Published: 2026-11-24 22:00 - Updated: 2026-11-25 22:00
Summary
Oracle Java SE and OpenJDK (Java4Shell) vulnerability
Notes
General Security Recommendations: To help ensure alignment with industry cybersecurity best practices, we strongly recommend following the guidance outlined in the Recommended Cybersecurity Best Practices document.
For More Information: This document summarizes the identified vulnerability or vulnerabilities and the recommended mitigation actions. For additional information or help protecting your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. Vulnerability & Incident Center: https://www.se.com/ww/en/about-us/cybersecurity/vulnerability-incident-center/
LEGAL DISCLAIMER: This notification document, the information contained herein, and any materials linked from it (collectively, this “Notification”) are intended to help provide an overview of the identified situation and suggested mitigation actions, remediation, fix, and/or general security recommendations and is provided on an “as-is” basis without warranty or guarantee of any kind. Schneider Electric disclaims all warranties relating to this Notification, either express or implied, including warranties of merchantability or fitness for a particular purpose. Schneider Electric makes no warranty that the Notification will resolve the identified situation. In no event shall Schneider Electric be liable for any damages or losses whatsoever in connection with this Notification, including direct, indirect, incidental, consequential, loss of business profits or special damages, even if Schneider Electric has been advised of the possibility of such damages. Your use of this Notification is at your own risk, and you are solely liable for any damages to your systems or assets or other losses that may result from your use of this Notification. Schneider Electric reserves the right to update or change this Notification at any time and in its sole discretion.
About Schneider Electric: Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com
Overview: Schneider Electric is aware of a vulnerability (Java4Shell) affecting certain versions of the Java Runtime Environment, including Oracle Java SE and OpenJDK-based distributions. Java is a widely used software platform that enables applications to run across different operating systems and environments. Our cybersecurity team is actively investigating the impact of the vulnerabilities on Schneider Electric products and will regularly update this document as information becomes available, and until further notice. Failure to apply the remediations or mitigations described below may risk compromise of the affected products, which could result in takeover of the affected Java components by an unauthenticated attacker with network access.
Use appropriate patch-management procedures when applying these patches. Back-up systems and test the patches in a development environment or offline infrastructure before deployment. Contact Schneider Electric's Customer Care Center for assistance with patch removal.

A CWE-122: Heap-based Buffer Overflow vulnerability exists in the Compiler component of Oracle Java SE, Oracle GraalVM for JDK, and Oracle GraalVM Enterprise Edition. The affected versions are: Oracle Java SE: 8u511b33-perf, 17.0.21.0.3, 21.0.13.0.3, 25.0.5.0.3, 27.0.1.0.3 Oracle GraalVM for JDK: 17.0.21.0.3 and 21.0.13.0.3 Oracle GraalVM Enterprise Edition: 21.3.20.0.3 The vulnerability also exists in OpenJDK ranges 27.0.1.0.3, 25.0.5.0.3, 21.0.13.0.3, 17.0.21.0.3. This vulnerability is difficult to exploit. An unauthenticated attacker with network access over multiple protocols could use it to compromise the affected components. Additional information about CVE-2026-114938 can be found here: https://www.cve.org/CVERecord?id=CVE-2026-114938, https://www.oracle.com/security-alerts/cspunov2026.html, https://openjdk.org/groups/vulnerability/advisories/2026-11-17

CWE-122 - Heap-based Buffer Overflow
Affected products
Product Identifier Version Remediation
EcoStruxure™ Security Expert - Enterprise Download Service Versions 1.0.23 and later
Schneider Electric / EcoStruxure™ Security Expert - Enterprise Download Service
vers:intdot/>=1.0.23
Product Identifier Version Remediation
Energy Management System Plus All Versions
Schneider Electric / Energy Management System Plus
vers:all/*
Mitigation
EcoStruxure Energy Operation All Versions
Schneider Electric / EcoStruxure Energy Operation
vers:all/*
Mitigation
PowerChute Network Shutdown Version 5.2 and prior
Schneider Electric / PowerChute Network Shutdown
vers:intdot/<=5.2
Vendor Fix fix
PowerChute Serial Shutdown Version 1.6 and prior
Schneider Electric / PowerChute Serial Shutdown
vers:intdot/<=1.6
Vendor Fix fix
PowerChute Network Advanced Versions 1.0.0 and 1.0.1
Schneider Electric / PowerChute Network Advanced
vers:intdot/1.0.0|1.0.1
Vendor Fix fix
EcoStruxure™ IT Data Center Expert Enterprise server AP9475 Versions 9.0 and later
Schneider Electric / EcoStruxure™ IT Data Center Expert / Enterprise server AP9475
vers:intdot/>=9.0
Mitigation fix
EcoStruxure IT Gateway Versions 2.0.0.20 to 2.3.0.10
Schneider Electric / EcoStruxure IT Gateway
vers:intdot/>=2.0.0.20|<=2.3.0.10
Mitigation fix
Vendor Fix
EcoStruxure IT Gateway Versions 1.21.0.6 to 1.24.0.12
Schneider Electric / EcoStruxure IT Gateway
vers:intdot/>=1.21.0.6|<=1.24.0.12
Mitigation fix
Vendor Fix
Unresolved product id: 12 —
Mitigation fix
Unresolved product id: 13 —
Mitigation fix
EcoStruxure™ Security Expert - Enterprise Download Service Versions prior to v1.0.23
Schneider Electric / EcoStruxure™ Security Expert - Enterprise Download Service
vers:intdot/<1.0.23
Vendor Fix fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Public",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "To help ensure alignment with industry cybersecurity best practices, we strongly recommend following the guidance outlined in the Recommended Cybersecurity Best Practices document.",
        "title": "General Security Recommendations"
      },
      {
        "category": "general",
        "text": "This document summarizes the identified vulnerability or vulnerabilities and the recommended mitigation actions. For additional information or help protecting your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. Vulnerability \u0026 Incident Center: https://www.se.com/ww/en/about-us/cybersecurity/vulnerability-incident-center/",
        "title": "For More Information"
      },
      {
        "category": "legal_disclaimer",
        "text": "This notification document, the information contained herein, and any materials linked from it (collectively, this \u201cNotification\u201d) are intended to help provide an overview of the identified situation and suggested mitigation actions, remediation, fix, and/or general security recommendations and is provided on an \u201cas-is\u201d basis without warranty or guarantee of any kind. Schneider Electric disclaims all warranties relating to this Notification, either express or implied, including warranties of merchantability or fitness for a particular purpose. Schneider Electric makes no warranty that the Notification will resolve the identified situation. In no event shall Schneider Electric be liable for any damages or losses whatsoever in connection with this Notification, including direct, indirect, incidental, consequential, loss of business profits or special damages, even if Schneider Electric has been advised of the possibility of such damages. Your use of this Notification is at your own risk, and you are solely liable for any damages to your systems or assets or other losses that may result from your use of this Notification. Schneider Electric reserves the right to update or change this Notification at any time and in its sole discretion.",
        "title": "LEGAL DISCLAIMER"
      },
      {
        "category": "general",
        "text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all.   www.se.com ",
        "title": "About Schneider Electric"
      },
      {
        "category": "summary",
        "text": "Schneider Electric is aware of a vulnerability (Java4Shell) affecting certain versions of the Java Runtime Environment, including Oracle Java SE and OpenJDK-based distributions. Java is a widely used software platform that enables applications to run across different operating systems and environments. Our cybersecurity team is actively investigating the impact of the vulnerabilities on Schneider Electric products and will regularly update this document as information becomes available, and until further notice. \n\nFailure to apply the remediations or mitigations described below may risk compromise of the affected products, which could result in takeover of the affected Java components by an unauthenticated attacker with network access.",
        "title": "Overview"
      },
      {
        "category": "other",
        "text": "Use appropriate patch-management procedures when applying these patches. Back-up systems and test the patches in a development environment or offline infrastructure before deployment. Contact Schneider Electric\u0027s Customer Care Center for assistance with patch removal."
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cpcert@se.com",
      "name": "Schneider Electric CPCERT",
      "namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
    },
    "references": [
      {
        "category": "self",
        "summary": "Third-Party Java Runtime Environment vulnerability (Java4Shell) on Multiple Products - SEVD-2026-328-01 PDF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-328-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-328-01.pdf"
      },
      {
        "category": "self",
        "summary": "Third-Party Java Runtime Environment vulnerability (Java4Shell) on Multiple Products - SEVD-2026-328-01 CSAF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-328-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2026-328-01.json"
      },
      {
        "category": "external",
        "summary": "Recommended Cybersecurity Best Practices",
        "url": "https://www.se.com/ww/en/download/document/7EN52-0390/"
      },
      {
        "category": "external",
        "summary": "CVE.org - CVE-2026-114938",
        "url": "https://www.cve.org/CVERecord?id=CVE-2026-114938"
      },
      {
        "category": "external",
        "summary": "OpenJDK advisory",
        "url": "https://openjdk.org/groups/vulnerability/advisories/2026-11-17"
      },
      {
        "category": "external",
        "summary": "Oracle advisory",
        "url": "https://www.oracle.com/security-alerts/cspunov2026.html"
      },
      {
        "category": "external",
        "summary": "Eclipse Adoptium (Temurin) advisory",
        "url": "https://adoptium.net/news/2026/11/temurin-november-2026-cspu-java4shell"
      }
    ],
    "title": "Oracle Java SE and OpenJDK (Java4Shell) vulnerability",
    "tracking": {
      "current_release_date": "2026-11-25T22:00:00.000Z",
      "generator": {
        "date": "2026-11-25T16:04:49.026Z",
        "engine": {
          "name": "Schneider Electric CSAF Generator",
          "version": "1.2"
        }
      },
      "id": "SEVD-2026-328-01",
      "initial_release_date": "2026-11-24T22:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-11-24T22:00:00.000Z",
          "number": "1.0.0",
          "summary": "Original Release"
        },
        {
          "date": "2026-11-25T22:00:00.000Z",
          "number": "2.0.0",
          "summary": "EcoStruxure\u2122 Security Expert - Enterprise Download Service was added as an affected product with remediations available. "
        }
      ],
      "status": "final",
      "version": "2.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Energy Management System Plus All Versions",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Energy Management System Plus"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "EcoStruxure Energy Operation All Versions",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure Energy Operation"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c=5.2",
                "product": {
                  "name": "PowerChute Network Shutdown Version 5.2 and prior",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerChute Network Shutdown"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c=1.6",
                "product": {
                  "name": "PowerChute Serial Shutdown Version 1.6 and prior",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerChute Serial Shutdown"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/1.0.0|1.0.1",
                "product": {
                  "name": "PowerChute Network Advanced Versions 1.0.0 and 1.0.1",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerChute Network Advanced"
          },
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "vers:intdot/\u003e=9.0",
                    "product": {
                      "name": "EcoStruxure\u2122 IT Data Center Expert Enterprise server AP9475 Versions 9.0 and later",
                      "product_id": "6"
                    }
                  }
                ],
                "category": "product_name",
                "name": "Enterprise server AP9475"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "vers:intdot/\u003e=9.0",
                    "product": {
                      "name": "EcoStruxure\u2122 IT Data Center Expert DCE Virtual Appliance Versions 9.0 and later",
                      "product_id": "7"
                    }
                  }
                ],
                "category": "product_name",
                "name": "DCE Virtual Appliance"
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 IT Data Center Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003e=2.0.0.20|\u003c=2.3.0.10",
                "product": {
                  "name": "EcoStruxure IT Gateway Versions 2.0.0.20 to 2.3.0.10",
                  "product_id": "8"
                }
              },
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003e=1.21.0.6|\u003c=1.24.0.12",
                "product": {
                  "name": "EcoStruxure IT Gateway Versions 1.21.0.6 to 1.24.0.12",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure IT Gateway"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c1.0.23",
                "product": {
                  "name": "EcoStruxure\u2122 Security Expert - Enterprise Download Service Versions prior to v1.0.23",
                  "product_id": "14"
                }
              },
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003e=1.0.23",
                "product": {
                  "name": "EcoStruxure\u2122 Security Expert - Enterprise Download Service Versions 1.0.23 and later",
                  "product_id": "15"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Security Expert - Enterprise Download Service"
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      },
      {
        "branches": [
          {
            "category": "product_name",
            "name": "VMware vSphere/ESXi",
            "product": {
              "name": "VMware vSphere/ESXi",
              "product_id": "10"
            }
          }
        ],
        "category": "vendor",
        "name": "Broadcom"
      },
      {
        "branches": [
          {
            "category": "product_name",
            "name": "Hyper-V",
            "product": {
              "name": "Microsoft Hyper-V",
              "product_id": "11"
            }
          }
        ],
        "category": "vendor",
        "name": "Microsoft"
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "EcoStruxure\u2122 IT Data Center Expert DCE Virtual Appliance Versions 9.0 and later installed on VMware vSphere/ESXi",
          "product_id": "12"
        },
        "product_reference": "7",
        "relates_to_product_reference": "10"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "EcoStruxure\u2122 IT Data Center Expert DCE Virtual Appliance Versions 9.0 and later installed on Microsoft Hyper-V",
          "product_id": "13"
        },
        "product_reference": "7",
        "relates_to_product_reference": "11"
      }
    ]
  },
  "vulnerabilities": [
    {
      "acknowledgments": [
        {
          "names": [
            "Internal"
          ],
          "organization": "Schneider Electric"
        }
      ],
      "cve": "CVE-2026-114938",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "description",
          "text": "A CWE-122: Heap-based Buffer Overflow vulnerability exists in the Compiler component of Oracle Java SE, Oracle GraalVM for JDK, and Oracle GraalVM Enterprise Edition. The affected versions are: Oracle Java SE: 8u511b33-perf, 17.0.21.0.3, 21.0.13.0.3, 25.0.5.0.3, 27.0.1.0.3 Oracle GraalVM for JDK: 17.0.21.0.3 and 21.0.13.0.3 Oracle GraalVM Enterprise Edition: 21.3.20.0.3 \n\nThe vulnerability also exists in OpenJDK ranges 27.0.1.0.3, 25.0.5.0.3, 21.0.13.0.3, 17.0.21.0.3. This vulnerability is difficult to exploit. An unauthenticated attacker with network access over multiple protocols could use it to compromise the affected components. Additional information about CVE-2026-114938 can be found here: https://www.cve.org/CVERecord?id=CVE-2026-114938, https://www.oracle.com/security-alerts/cspunov2026.html, https://openjdk.org/groups/vulnerability/advisories/2026-11-17",
          "title": "CVE Description"
        },
        {
          "category": "details",
          "text": "CVSS v4.0 Base Score 9.2 | Critical | [CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)",
          "title": "CVSS 4.0 Score"
        }
      ],
      "product_status": {
        "fixed": [
          "15"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "8",
          "9",
          "12",
          "13",
          "14"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Schneider Electric is working on a remediation and will update this security notification when it becomes available. In the meantime, customers are strongly encouraged to apply the following mitigations to reduce the risk of exploitation: \n\n* Harden the network in Energy Management System Plus deployment environment following the network security manual included in the installation package. \n\n* Tighten access for accounts with system admin privileges and rotate all administrative credentials to eliminate attack vectors leveraging compromised privileged accounts.",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is working on a remediation and will update this security notification when it becomes available. In the meantime, customers are strongly encouraged to apply the following mitigations to reduce the risk of exploitation:\n\n* Double-check and harden the network in EcoStruxure Energy Operation deployment environment following the network security manual included in the installation package. \n\n* Tighten access for accounts with system admin privileges and rotate all administrative credentials to eliminate attack vectors leveraging compromised privileged accounts.",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "For remediation instructions, refer to https://www.se.com/us/en/faqs/FAQ000284669/",
          "product_ids": [
            "3"
          ],
          "url": "https://www.se.com/us/en/faqs/FAQ000284669/"
        },
        {
          "category": "vendor_fix",
          "details": "For remediation instructions, refer to https://www.se.com/us/en/faqs/FAQ000284669/",
          "product_ids": [
            "4"
          ],
          "url": "https://www.se.com/us/en/faqs/FAQ000284669/"
        },
        {
          "category": "vendor_fix",
          "details": "For remediation instructions, refer to https://www.se.com/us/en/faqs/FAQ000284953/",
          "product_ids": [
            "5"
          ],
          "url": "https://www.se.com/us/en/faqs/FAQ000284953/"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is working on a remediation and will update this security notification when it becomes available. In the meantime, customers are strongly encouraged to apply the following mitigations to reduce the risk of exploitation: \n\n* Restrict HTTP and HTTPS access to the Data Center Expert server to trusted management networks or hosts, using firewall rules or network segmentation. \n\n* Follow the hardening guidance in the EcoStruxure IT Data Center Expert Security Handbook: https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553 \n\n DCE Enterprise server (AP9475). Contact Schneider Electric Technical Support. Support can check whether your server\u0027s processor is affected and, if so, apply a configuration change that disables the affected Java optimization. The change restarts the DCE server application, which pauses monitoring for a few minutes.",
          "product_ids": [
            "6"
          ],
          "url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is working on a remediation and will update this security notification when it becomes available. In the meantime, customers are strongly encouraged to apply the following mitigations to reduce the risk of exploitation: \n\n* Restrict HTTP and HTTPS access to the Data Center Expert server to trusted management networks or hosts, using firewall rules or network segmentation. \n\n* Follow the hardening guidance in the EcoStruxure IT Data Center Expert Security Handbook: https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553 \n\nDCE Virtual Appliance \n\nThe hypervisor settings below require access to your VMware or Hyper-V management tools. Apply the mitigations provided below or contact Schneider Electric Technical Support, who can help you apply an alternative mitigation.\n\n* DCE Virtual Appliance on VMware vSphere/ESXi \n\n Hide the AVX-512 VBMI instructions from the DCE virtual machine by setting Enhanced vMotion Compatibility (EVC) to a baseline below Intel Ice Lake or AMD Zen 4: \n\n* Intel hosts: an EVC mode of Intel Cascade Lake or lower. If the virtual machine does not power on with Intel Cascade Lake, use Intel Skylake. \n\n* AMD hosts: an EVC mode of AMD Zen 3 or lower. Per-VM EVC (vSphere 6.7 or later, VM hardware version 14 or later): 1. Shut down the DCE virtual machine. 2. In the vSphere Client, select the VM and go to Configure \u003e VMware EVC \u003e Edit. 3. Enable EVC for the VM, select the mode above, and click OK. 4. Power on the VM. Alternatively, set the same EVC mode on the cluster. Changing cluster EVC to a lower mode requires all VMs in the cluster that use the higher feature set to be powered off.",
          "product_ids": [
            "12"
          ],
          "url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is working on a remediation and will update this security notification when it becomes available. In the meantime, customers are strongly encouraged to apply the following mitigations to reduce the risk of exploitation: \n\n* Restrict HTTP and HTTPS access to the Data Center Expert server to trusted management networks or hosts, using firewall rules or network segmentation. \n\n* Follow the hardening guidance in the EcoStruxure IT Data Center Expert Security Handbook: https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553 \n\nDCE Virtual Appliance \n\nThe hypervisor settings below require access to your VMware or Hyper-V management tools. Apply the mitigations provided below or contact Schneider Electric Technical Support, who can help you apply an alternative mitigation.\n\n* DCE Virtual Appliance on Microsoft Hyper-V Enable processor compatibility mode for the DCE virtual machine. This hides newer instruction sets, including AVX-512, from the guest. 1. Shut down the DCE virtual machine. 2. In Hyper-V Manager, open the VM Settings \u003e Processor \u003e Compatibility and select Migrate to a physical computer with a different processor version. Or, in PowerShell, run: Set-VMProcessor -VMName \"\u003cDCE VM name\u003e\" -CompatibilityForMigrationEnabled $true 3. Power on the VM. These hypervisor settings hide processor features from all software in the DCE virtual machine, not only from the affected Java code, so performance may be lower after the change. Hyper-V processor compatibility mode hides more features than the VMware EVC modes above. Changing EVC at the cluster level also affects the other virtual machines in that cluster.",
          "product_ids": [
            "13"
          ],
          "url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
        },
        {
          "category": "mitigation",
          "details": "Follow the hardening guidance in Security hardening section https://community.se.com/t5/EcoStruxure-IT-Gateway-security/EcoStruxure-IT-Gateway-Security-Handbook/ta-p/481970",
          "product_ids": [
            "8",
            "9"
          ],
          "url": "https://community.se.com/t5/EcoStruxure-IT-Gateway-security/EcoStruxure-IT-Gateway-Security-Handbook/ta-p/481970"
        },
        {
          "category": "vendor_fix",
          "details": "For versions v2.0.0.20 through v2.3.0.10, customers should: \n\n* Edit the file /conf/application-gateway-jvm.options \n\n* On a new line add the following: -XX:-UseBASE64Intrinsics \n\nRestart the Gateway service.",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "service"
          }
        },
        {
          "category": "vendor_fix",
          "details": "For versions v1.21.0.6 through v1.24.0.12, customers should: \n\n* Edit the file /gateway/conf/installerCustom.options \n\n* On a new line add the following: -XX:-UseBASE64Intrinsics \n\nRestart the Gateway service.",
          "product_ids": [
            "9"
          ],
          "restart_required": {
            "category": "service"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Versions 1.0.23 and later of Enterprise Download Service include a fix for the vulnerability and are available at: https://www.se.com/myschneider/catalogBrowse/us/en/range/65214#software-and-firmware \n\n Reboot is required",
          "product_ids": [
            "14"
          ],
          "restart_required": {
            "category": "service"
          },
          "url": "https://www.se.com/myschneider/catalogBrowse/us/en/range/65214#software-and-firmware"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "8",
            "9",
            "12",
            "13",
            "14"
          ]
        }
      ],
      "title": "CVE-2026-114938"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…