Occupancy monitoring via unencrypted RF communication
Summary
The static codes used for information transmission
throughout the 433.92 MHz system of the Guardian 2 system allow an attacker in
proximity to monitor the movements of users inside the premises where the
sensors are set up. This is further aided by the fact that codes transmitted
reveal sensor type, although sensor location cannot be inferred from this
traffic alone.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-19 15:10 UTC
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Onyx Cookware ApS | Nexsmart Guardian 2 (Alarm system) |
Affected:
0
(semver)
|
Date Public
2026-11-19 09:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82949",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-19T15:10:44.258774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-19T15:10:55.174Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Nexsmart Guardian 2 (Alarm system)",
"vendor": "Onyx Cookware ApS",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Elias Lindstr\u00f6m"
},
{
"lang": "en",
"type": "coordinator",
"value": "CERT-SE"
}
],
"datePublic": "2026-11-19T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.\u003c/p\u003e"
}
],
"value": "The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-19T10:32:13.090Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ci\u003e\u003cspan\u003eNexsmart reported suspending sales and described a phase-out of the current Guardian models.\u0026nbsp;\u003c/span\u003e\u003cspan\u003eIf you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.\u003c/span\u003e\u003c/i\u003e"
}
],
"value": "Nexsmart reported suspending sales and described a phase-out of the current Guardian models.\u00a0If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Occupancy monitoring via unencrypted RF communication",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-82949",
"datePublished": "2026-11-19T10:32:13.090Z",
"dateReserved": "2026-08-31T12:26:22.054Z",
"dateUpdated": "2026-11-19T15:10:55.174Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-82949",
"date": "2026-11-22",
"epss": "0.00142",
"percentile": "0.03488"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "affected",
"product": "Nexsmart Guardian 2 (Alarm system)",
"vendor": "Onyx Cookware ApS",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone."
}
],
"id": "CVE-2026-82949",
"lastModified": "2026-11-19T16:22:00.767",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-82949",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-19T15:10:44.258774Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-11-19T11:17:08.580",
"references": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"url": "https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"
}
],
"sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"vulnStatus": "Received",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82949",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-19T15:10:44.258774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-19T15:10:51.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Nexsmart Guardian 2 (Alarm system)",
"vendor": "Onyx Cookware ApS",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Elias Lindstr\u00f6m"
},
{
"lang": "en",
"type": "coordinator",
"value": "CERT-SE"
}
],
"datePublic": "2026-11-19T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.\u003c/p\u003e"
}
],
"value": "The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-19T10:32:13.090Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ci\u003e\u003cspan\u003eNexsmart reported suspending sales and described a phase-out of the current Guardian models.\u0026nbsp;\u003c/span\u003e\u003cspan\u003eIf you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.\u003c/span\u003e\u003c/i\u003e"
}
],
"value": "Nexsmart reported suspending sales and described a phase-out of the current Guardian models.\u00a0If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Occupancy monitoring via unencrypted RF communication",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-82949",
"datePublished": "2026-11-19T10:32:13.090Z",
"dateReserved": "2026-08-31T12:26:22.054Z",
"dateUpdated": "2026-11-19T15:10:55.174Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…