CVE-2026-58051 (GCVE-0-2026-58051)

Vulnerability from cvelistv5 – Published: 2026-06-28 01:32 – Updated: 2026-11-10 12:48
VLAI
Title
libssh2 - Free of Uninitialized Pointer in publickey List Cleanup
Summary
libssh2 through 1.11.1 grows its publickey list with SSH2_REALLOC but does not zero-initialize new entries before parsing populates them, so a parse failure reaching the cleanup path leaves libssh2_publickey_list_free operating on an uninitialized entry. A malicious SSH server offering the publickey subsystem can use a malformed response to make cleanup free an uninitialized, attacker-influenceable attrs pointer in a connecting libssh2 client.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-29 12:49 UTC
CWE
  • CWE-908 - Use of Uninitialized Resource
Date Public
2026-06-25 00:00
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-58051",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-29T12:49:30.651264Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-29T12:50:00.766Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "V3.1.7",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "V3.1.7",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "V3.1.7",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "V3.1.7",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "V3.1.7",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-11-10T12:48:59.666Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-457936.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "libssh2",
          "vendor": "libssh2",
          "versions": [
            {
              "lessThanOrEqual": "1.11.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:libssh2:libssh2:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.11.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ashdfrkl"
        }
      ],
      "datePublic": "2026-06-25T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "libssh2 through 1.11.1 grows its publickey list with SSH2_REALLOC but does not zero-initialize new entries before parsing populates them, so a parse failure reaching the cleanup path leaves libssh2_publickey_list_free operating on an uninitialized entry. A malicious SSH server offering the publickey subsystem can use a malformed response to make cleanup free an uninitialized, attacker-influenceable attrs pointer in a connecting libssh2 client."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS"
        },
        {
          "cvssV4_0": {
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-908",
              "description": "Use of Uninitialized Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-28T01:32:54.283Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "Proof of Concept",
          "tags": [
            "exploit",
            "third-party-advisory"
          ],
          "url": "https://github.com/bikini/exploitarium/tree/main/libssh2-publickey-list-calc-poc"
        },
        {
          "name": "src/publickey.c",
          "tags": [
            "product"
          ],
          "url": "https://github.com/libssh2/libssh2/blob/master/src/publickey.c"
        },
        {
          "name": "VulnCheck Advisory: libssh2 - Free of Uninitialized Pointer in publickey List Cleanup",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/libssh2-free-of-uninitialized-pointer-in-publickey-list-cleanup"
        }
      ],
      "title": "libssh2 - Free of Uninitialized Pointer in publickey List Cleanup",
      "x_generator": {
        "engine": "vulncheck-endgame"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2026-58051",
    "datePublished": "2026-06-28T01:32:54.283Z",
    "dateReserved": "2026-06-28T00:55:25.426Z",
    "dateUpdated": "2026-11-10T12:48:59.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-58051",
      "date": "2026-11-17",
      "epss": "0.00286",
      "percentile": "0.21371"
    },
    "microsoft_vex": {
      "current_release_date": "2026-11-16T23:01:07.000Z",
      "cve": "CVE-2026-58051",
      "id": "msrc_CVE-2026-58051",
      "initial_release_date": "2026-06-29T01:06:18.000Z",
      "product_status:fixed": "1",
      "product_status:known_affected": "4",
      "product_status:known_not_affected": "4",
      "product_status:under_investigation": "4",
      "source": "Microsoft CSAF VEX",
      "status": "final",
      "title": "libssh2 - Free of Uninitialized Pointer in publickey List Cleanup",
      "url": "https://msrc.microsoft.com/csaf/vex/2026/msrc_cve-2026-58051.json",
      "version": "14"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "product": "libssh2",
                "vendor": "libssh2",
                "versions": [
                  {
                    "lessThanOrEqual": "1.11.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "disclosure@vulncheck.com"
          },
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:libssh2:libssh2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "00D62356-F677-41CF-AC66-2871AD2112BA",
                    "versionEndIncluding": "1.11.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "libssh2 through 1.11.1 grows its publickey list with SSH2_REALLOC but does not zero-initialize new entries before parsing populates them, so a parse failure reaching the cleanup path leaves libssh2_publickey_list_free operating on an uninitialized entry. A malicious SSH server offering the publickey subsystem can use a malformed response to make cleanup free an uninitialized, attacker-influenceable attrs pointer in a connecting libssh2 client."
          },
          {
            "lang": "es",
            "value": "libssh2 hasta la versi\u00f3n 1.11.1 aumenta su lista de claves p\u00fablicas con SSH2_REALLOC pero no inicializa a cero las nuevas entradas antes de que el an\u00e1lisis las complete, por lo que un fallo de an\u00e1lisis que alcanza la ruta de limpieza deja a libssh2_publickey_list_free operando sobre una entrada no inicializada. Un servidor SSH malicioso que ofrece el subsistema publickey puede usar una respuesta malformada para hacer que la limpieza libere un puntero attrs no inicializado y que puede ser influenciado por el atacante en un cliente libssh2 que se conecta."
          }
        ],
        "id": "CVE-2026-58051",
        "lastModified": "2026-11-10T13:19:28.993",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.2,
              "impactScore": 4.2,
              "source": "disclosure@vulncheck.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "disclosure@vulncheck.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-58051",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-29T12:49:30.651264Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-06-28T02:16:32.153",
        "references": [
          {
            "source": "disclosure@vulncheck.com",
            "tags": [
              "Broken Link"
            ],
            "url": "https://github.com/bikini/exploitarium/tree/main/libssh2-publickey-list-calc-poc"
          },
          {
            "source": "disclosure@vulncheck.com",
            "tags": [
              "Product"
            ],
            "url": "https://github.com/libssh2/libssh2/blob/master/src/publickey.c"
          },
          {
            "source": "disclosure@vulncheck.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.vulncheck.com/advisories/libssh2-free-of-uninitialized-pointer-in-publickey-list-cleanup"
          },
          {
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-457936.html"
          }
        ],
        "sourceIdentifier": "disclosure@vulncheck.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-908"
              }
            ],
            "source": "disclosure@vulncheck.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "aggregate_severity": "Moderate",
      "current_release_date": "2026-11-05T22:17:23+00:00",
      "cve": "CVE-2026-58051",
      "id": "CVE-2026-58051",
      "initial_release_date": "2026-06-28T01:32:54.283000+00:00",
      "product_status:fixed": "14",
      "product_status:known_affected": "8",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "libssh2: libssh2: Denial of service or information disclosure via malformed SSH publickey response",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-58051.json",
      "version": "3"
    },
    "suse_vex": {
      "aggregate_severity": "moderate",
      "current_release_date": "2026-10-10T01:17:46Z",
      "cve": "CVE-2026-58051",
      "id": "CVE-2026-58051",
      "initial_release_date": "2026-06-30T01:42:21Z",
      "product_status:known_affected": "454",
      "product_status:recommended": "75",
      "source": "SUSE CSAF VEX",
      "status": "interim",
      "title": "SUSE CVE CVE-2026-58051",
      "url": "https://ftp.suse.com/pub/projects/security/csaf-vex/2026/cve-2026-58051.json",
      "version": "15"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V3.1.7",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-10T12:48:59.666Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-457936.html"
              }
            ],
            "x_adpType": "supplier"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-58051",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-29T12:49:30.651264Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-29T12:49:52.395Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "libssh2",
              "vendor": "libssh2",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:libssh2:libssh2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.11.1",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ashdfrkl"
            }
          ],
          "datePublic": "2026-06-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "libssh2 through 1.11.1 grows its publickey list with SSH2_REALLOC but does not zero-initialize new entries before parsing populates them, so a parse failure reaching the cleanup path leaves libssh2_publickey_list_free operating on an uninitialized entry. A malicious SSH server offering the publickey subsystem can use a malformed response to make cleanup free an uninitialized, attacker-influenceable attrs pointer in a connecting libssh2 client."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            },
            {
              "cvssV4_0": {
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-908",
                  "description": "Use of Uninitialized Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-28T01:32:54.283Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Proof of Concept",
              "tags": [
                "exploit",
                "third-party-advisory"
              ],
              "url": "https://github.com/bikini/exploitarium/tree/main/libssh2-publickey-list-calc-poc"
            },
            {
              "name": "src/publickey.c",
              "tags": [
                "product"
              ],
              "url": "https://github.com/libssh2/libssh2/blob/master/src/publickey.c"
            },
            {
              "name": "VulnCheck Advisory: libssh2 - Free of Uninitialized Pointer in publickey List Cleanup",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/libssh2-free-of-uninitialized-pointer-in-publickey-list-cleanup"
            }
          ],
          "title": "libssh2 - Free of Uninitialized Pointer in publickey List Cleanup",
          "x_generator": {
            "engine": "vulncheck-endgame"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-58051",
        "datePublished": "2026-06-28T01:32:54.283Z",
        "dateReserved": "2026-06-28T00:55:25.426Z",
        "dateUpdated": "2026-11-10T12:48:59.666Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…