CVE-2021-45971 (GCVE-0-2021-45971)

Vulnerability from cvelistv5 – Published: 2022-01-05 23:09 – Updated: 2026-08-11 12:22
VLAI
Summary
An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData).
CWE
  • n/a
Impacted products
Vendor Product Version
Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
Create a notification for this product.
Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
Create a notification for this product.
Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
Create a notification for this product.
Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
Create a notification for this product.
Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
Create a notification for this product.
Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
Create a notification for this product.
Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
Create a notification for this product.
Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
Create a notification for this product.
Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
Create a notification for this product.
Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
Create a notification for this product.
Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
Create a notification for this product.
Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
Create a notification for this product.
Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
Create a notification for this product.
Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
Create a notification for this product.
Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
Create a notification for this product.
Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
Create a notification for this product.
Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
Create a notification for this product.
Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:12:49.634Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/796611"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808 - BIOS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V1.0.202N",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M5",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V22.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M6",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V26.01.13",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC127E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V27.01.09",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC227G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC277G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC\u00a0IPC277G PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC327G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC377G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC627E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC647E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC677E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC847E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC ITP1000",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V23.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPLUS IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-11T12:22:26.567Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:06:45.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45971",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220216-0004/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45971",
    "datePublished": "2022-01-05T23:09:47.000Z",
    "dateReserved": "2022-01-01T00:00:00.000Z",
    "dateUpdated": "2026-08-11T12:22:26.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-45971",
      "date": "2026-10-02",
      "epss": "0.00279",
      "percentile": "0.18489"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          },
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A6D01558-E38E-4A46-94A7-6F43BECA2599",
                    "versionEndExcluding": "5.16.25",
                    "versionStartIncluding": "5.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1E8E5C28-ACA1-46AC-B0C0-958B7805F75A",
                    "versionEndExcluding": "5.26.25",
                    "versionStartIncluding": "5.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6AA45E92-34FA-4583-938D-2139F870034F",
                    "versionEndExcluding": "5.35.25",
                    "versionStartIncluding": "5.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "81782BA4-3BE8-4C12-BBA1-584C7EF98358",
                    "versionEndExcluding": "5.43.25",
                    "versionStartIncluding": "5.4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6EC229D4-4C67-4B44-ACEE-48DB31C87C4C",
                    "versionEndExcluding": "05.51.25",
                    "versionStartIncluding": "5.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData)."
          },
          {
            "lang": "es",
            "value": "Se ha detectado un problema en SdHostDriver en Insyde InsydeH2O con el kernel 5.1 anteriores a  05.16.25, 5.2 anteriores a  05.26.25, 5.3 anteriores a  05.35.25, 5.4 anteriores a  05.43.25 y 5.5 anteriores a  05.51.25. Se presenta una vulnerabilidad en la rama SMM (System Management Mode) que registra un manejador SWSMI que no comprueba ni valida suficientemente el puntero del b\u00fafer asignado (CommBufferData)."
          }
        ],
        "id": "CVE-2021-45971",
        "lastModified": "2026-08-11T13:17:23.060",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.5,
              "impactScore": 6.0,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2022-01-06T00:15:07.910",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://www.kb.cert.org/vuls/id/796611"
          },
          {
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…