CVE-2020-13859 (GCVE-0-2020-13859)

Vulnerability from cvelistv5 – Published: 2021-02-01 01:27 – Updated: 2024-08-04 12:32
VLAI
Summary
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature.
CWE
  • n/a
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:32:14.100Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-01T01:27:07.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-13859",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mofinetwork.com/index.php?main_page=page\u0026id=14",
              "refsource": "MISC",
              "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
            },
            {
              "name": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/",
              "refsource": "MISC",
              "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-13859",
    "datePublished": "2021-02-01T01:27:07.000Z",
    "dateReserved": "2020-06-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T12:32:14.100Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-13859",
      "date": "2026-10-15",
      "epss": "0.01178",
      "percentile": "0.67091"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B22253CC-AFEF-4A42-8ED9-5B5348F5937A",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8C7B2A7E-0E09-412C-B540-9C5DFD16767D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature."
          },
          {
            "lang": "es",
            "value": "Se detect\u00f3 un problema en los dispositivos Mofi Network MOFI4500-4GXeLTE versi\u00f3n 4.0.8-std.\u0026#xa0;Un error de formato en el archivo /etc/shadow, junto con un error l\u00f3gico en el framework de la interfaz de configuraci\u00f3n de LuCI - OpenWrt, permite a la cuenta de sistema no documentada mofidev iniciar sesi\u00f3n en la interfaz de administraci\u00f3n cgi-bin/luci/quick/wizard sin una contrase\u00f1a al abusar de una funcionalidad forgotten-password"
          }
        ],
        "id": "CVE-2020-13859",
        "lastModified": "2026-06-17T02:53:47.613",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-02-01T02:15:14.800",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Technical Description",
              "Third Party Advisory"
            ],
            "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Technical Description",
              "Third Party Advisory"
            ],
            "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              },
              {
                "lang": "en",
                "value": "CWE-755"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…