Search

Find a vulnerability

Search criteria

    334 vulnerabilities by tenda

    CVE-2026-136554 (GCVE-0-2026-136554)

    Vulnerability from nvd – Published: 2026-11-25 06:45 – Updated: 2026-11-25 06:45
    VLAI
    Title
    Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication
    Summary
    A flaw has been found in Tenda RX3 16.03.13.11_multi. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet of the component httpd. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda RX3 16.03.13.11_multi. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet of the component httpd. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.5,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:45:13.355Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443411 | Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443411"
            },
            {
              "name": "VDB-443411 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443411/cti"
            },
            {
              "name": "CVE-2026-136554 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136554"
            },
            {
              "name": "Submit #1057774 | Tenda RX3 V16.03.13.11_multi Missing Authentication for Critical Function",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057774"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/factory_reset_no_auth/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:16:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136554",
        "datePublished": "2026-11-25T06:45:13.355Z",
        "dateReserved": "2026-11-24T21:10:24.253Z",
        "dateUpdated": "2026-11-25T06:45:13.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136553 (GCVE-0-2026-136553)

    Vulnerability from nvd – Published: 2026-11-25 06:30 – Updated: 2026-11-25 06:30
    VLAI
    Title
    Tenda RX3 fast_setting_wifi_set improper authentication
    Summary
    A vulnerability was detected in Tenda RX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Performing a manipulation of the argument loginPwd results in improper authentication. It is possible to initiate the attack remotely. The exploit is now public and may be used.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda RX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Performing a manipulation of the argument loginPwd results in improper authentication. It is possible to initiate the attack remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:30:24.581Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443410 | Tenda RX3 fast_setting_wifi_set improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443410"
            },
            {
              "name": "VDB-443410 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443410/cti"
            },
            {
              "name": "CVE-2026-136553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136553"
            },
            {
              "name": "Submit #1057770 | Tenda RX3 V16.03.13.11_multi Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057770"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/password_change_no_verify/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 fast_setting_wifi_set improper authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136553",
        "datePublished": "2026-11-25T06:30:24.581Z",
        "dateReserved": "2026-11-24T21:10:19.599Z",
        "dateUpdated": "2026-11-25T06:30:24.581Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136552 (GCVE-0-2026-136552)

    Vulnerability from nvd – Published: 2026-11-25 06:00 – Updated: 2026-11-25 06:00
    VLAI
    Title
    Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection
    Summary
    A security vulnerability has been detected in Tenda RX3 16.03.13.11_multi. This impacts the function formSetIPv6status of the file /goform/setIPv6Status of the component multiWAN. Such manipulation of the argument remoteIP leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "multiWAN"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda RX3 16.03.13.11_multi. This impacts the function formSetIPv6status of the file /goform/setIPv6Status of the component multiWAN. Such manipulation of the argument remoteIP leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:00:27.450Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443409 | Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443409"
            },
            {
              "name": "VDB-443409 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443409/cti"
            },
            {
              "name": "CVE-2026-136552 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136552"
            },
            {
              "name": "Submit #1057769 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057769"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_ipv6/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:51.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136552",
        "datePublished": "2026-11-25T06:00:27.450Z",
        "dateReserved": "2026-11-24T21:10:15.190Z",
        "dateUpdated": "2026-11-25T06:00:27.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136550 (GCVE-0-2026-136550)

    Vulnerability from nvd – Published: 2026-11-25 05:45 – Updated: 2026-11-25 05:45
    VLAI
    Title
    Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection
    Summary
    A weakness has been identified in Tenda RX3 16.03.13.11_multi. This affects the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. This manipulation of the argument mac causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda RX3 16.03.13.11_multi. This affects the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. This manipulation of the argument mac causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:45:18.522Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443408 | Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443408"
            },
            {
              "name": "VDB-443408 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443408/cti"
            },
            {
              "name": "CVE-2026-136550 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136550"
            },
            {
              "name": "Submit #1057768 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057768"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_mac/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136550",
        "datePublished": "2026-11-25T05:45:18.522Z",
        "dateReserved": "2026-11-24T21:10:10.266Z",
        "dateUpdated": "2026-11-25T05:45:18.522Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136549 (GCVE-0-2026-136549)

    Vulnerability from nvd – Published: 2026-11-25 05:30 – Updated: 2026-11-25 05:30
    VLAI
    Title
    Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection
    Summary
    A security flaw has been discovered in Tenda RX3 16.03.13.11_multi. The impacted element is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda RX3 16.03.13.11_multi. The impacted element is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:30:17.472Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443407 | Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443407"
            },
            {
              "name": "VDB-443407 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443407/cti"
            },
            {
              "name": "CVE-2026-136549 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136549"
            },
            {
              "name": "Submit #1057767 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057767"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_remoteIp/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:42.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136549",
        "datePublished": "2026-11-25T05:30:17.472Z",
        "dateReserved": "2026-11-24T21:10:04.044Z",
        "dateUpdated": "2026-11-25T05:30:17.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136548 (GCVE-0-2026-136548)

    Vulnerability from nvd – Published: 2026-11-25 05:15 – Updated: 2026-11-25 05:15
    VLAI
    Title
    Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow
    Summary
    A vulnerability was identified in Tenda RX3 16.03.13.11. The affected element is an unknown function of the file /bin/auto_discover of the component GBK-to-UTF-8 Conversion. The manipulation of the argument Hostname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "GBK-to-UTF-8 Conversion"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda RX3 16.03.13.11. The affected element is an unknown function of the file /bin/auto_discover of the component GBK-to-UTF-8 Conversion. The manipulation of the argument Hostname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:15:17.187Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443406 | Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443406"
            },
            {
              "name": "VDB-443406 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443406/cti"
            },
            {
              "name": "CVE-2026-136548 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136548"
            },
            {
              "name": "Submit #1057714 | Tenda RX3 V16.03.13.11_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057714"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/dhcp_gbk_overflow/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136548",
        "datePublished": "2026-11-25T05:15:17.187Z",
        "dateReserved": "2026-11-24T21:09:59.572Z",
        "dateUpdated": "2026-11-25T05:15:17.187Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136547 (GCVE-0-2026-136547)

    Vulnerability from nvd – Published: 2026-11-25 05:00 – Updated: 2026-11-25 05:00
    VLAI
    Title
    Tenda RX3 httpd R7WebsSecurityHandler improper authentication
    Summary
    A vulnerability was determined in Tenda RX3 16.03.13.11_multi. Impacted is the function R7WebsSecurityHandler of the component httpd. Executing a manipulation can lead to improper authentication. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda RX3 16.03.13.11_multi. Impacted is the function R7WebsSecurityHandler of the component httpd. Executing a manipulation can lead to improper authentication. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:00:21.550Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443405 | Tenda RX3 httpd R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443405"
            },
            {
              "name": "VDB-443405 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443405/cti"
            },
            {
              "name": "CVE-2026-136547 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136547"
            },
            {
              "name": "Submit #1057713 | Tenda RX3 V16.03.13.11_multi Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057713"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/auth_bypass/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 httpd R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136547",
        "datePublished": "2026-11-25T05:00:21.550Z",
        "dateReserved": "2026-11-24T21:09:55.131Z",
        "dateUpdated": "2026-11-25T05:00:21.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-129258 (GCVE-0-2026-129258)

    Vulnerability from nvd – Published: 2026-11-14 14:30 – Updated: 2026-11-16 15:37
    VLAI
    Title
    Tenda AC18 Firmware Upgrade upgrade data authenticity
    Summary
    A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 15:12 UTC
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    References
    URL Tags
    https://vuldb.com/vuln/437295 vdb-entrytechnical-description
    https://vuldb.com/vuln/437295/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-129258 third-party-advisory
    https://vuldb.com/submit/1043033 third-party-advisory
    https://github.com/longqx223/Tenda-ac-18-V15.03.0… exploitpatch
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.05_multi
    Affected: 15.03.05.19 Build 6318
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-129258",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T15:12:58.266813Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:37:49.793Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Firmware Upgrade Handler"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.05_multi"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.19 Build 6318"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Longqxxixi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-14T14:30:22.937Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-437295 | Tenda AC18 Firmware Upgrade upgrade data authenticity",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/437295"
            },
            {
              "name": "VDB-437295 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/437295/cti"
            },
            {
              "name": "CVE-2026-129258 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-129258"
            },
            {
              "name": "Submit #1043033 | Tenda AC18 (AC18V1.0BR) wireless router V15.03.05.05_multi ,V15.03.05.19 build 6318  Insufficient Verification of Data Authenticity",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1043033"
            },
            {
              "tags": [
                "exploit",
                "patch"
              ],
              "url": "https://github.com/longqx223/Tenda-ac-18-V15.03.05.05-/blob/main/2026-10-19-Tenda-AC18-unsigned-firmware-update-advisory-EN.pdf"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-13T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-13T21:02:27.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Firmware Upgrade upgrade data authenticity",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-129258",
        "datePublished": "2026-11-14T14:30:22.937Z",
        "dateReserved": "2026-11-13T19:57:13.854Z",
        "dateUpdated": "2026-11-16T15:37:49.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123966 (GCVE-0-2026-123966)

    Vulnerability from nvd – Published: 2026-11-07 13:45 – Updated: 2026-11-09 22:41
    VLAI
    Title
    Tenda AC19 saveParentControlInfo heap-based overflow
    Summary
    A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 22:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-123966",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T22:40:09.150272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T22:41:45.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-07T13:45:19.423Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-432038 | Tenda AC19 saveParentControlInfo heap-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/432038"
            },
            {
              "name": "VDB-432038 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/432038/cti"
            },
            {
              "name": "CVE-2026-123966 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-123966"
            },
            {
              "name": "Submit #1035173 | Tenda AC19 V16.03.10.07 Heap-Based Buffer Overflow (CWE-122)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1035173"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-AC19-saveParentControlInfo/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-06T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-06T18:21:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 saveParentControlInfo heap-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-123966",
        "datePublished": "2026-11-07T13:45:19.423Z",
        "dateReserved": "2026-11-06T17:16:21.436Z",
        "dateUpdated": "2026-11-09T22:41:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-118238 (GCVE-0-2026-118238)

    Vulnerability from nvd – Published: 2026-10-30 15:08 – Updated: 2026-10-30 17:07
    VLAI
    Title
    CVE-2026-118238
    Summary
    The Tenda W18E web management server is vulnerable to OS command injection via the "diagnose" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 17:07 UTC
    CWE
    Impacted products
    Vendor Product Version
    Tenda W18E Affected: V16.01.0.20
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "HIGH",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-118238",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T17:07:03.133377Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T17:07:06.917Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "W18E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "V16.01.0.20"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Tenda W18E web management server is vulnerable to OS command injection via the \"diagnose\" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-30T15:08:41.752Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "url": "https://cushz.github.io/en/exploit-development/2026/10/27/hacking-routers-for-fun-and-not-profit.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2026-118238",
          "x_generator": {
            "engine": "VINCE 3.0.52",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2026-118238"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2026-118238",
        "datePublished": "2026-10-30T15:08:41.752Z",
        "dateReserved": "2026-10-27T19:49:03.088Z",
        "dateUpdated": "2026-10-30T17:07:06.917Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115797 (GCVE-0-2026-115797)

    Vulnerability from nvd – Published: 2026-10-23 20:00 – Updated: 2026-10-29 14:19
    VLAI
    Title
    Tenda F6 Web Management cleartext transmission
    Summary
    A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-29 14:18 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    • CWE-310 - Cryptographic Issues
    References
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-115797",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-29T14:18:52.852412Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-29T14:19:14.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abdullah Altamimi"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Alshalan"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Almukhalfi"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 2.6,
                "vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-310",
                  "description": "Cryptographic Issues",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:10:39.242Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425975 | Tenda F6 Web Management cleartext transmission",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/425975"
            },
            {
              "name": "VDB-425975 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425975/cti"
            },
            {
              "name": "CVE-2026-115797 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115797"
            },
            {
              "name": "Submit #1022076 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cleartext Transmission of Sensitive Information (CWE-319)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022076"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/edit/main/02-Cleartext_Transmission.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-26T17:12:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cleartext transmission",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115797",
        "datePublished": "2026-10-23T20:00:16.370Z",
        "dateReserved": "2026-10-23T14:57:47.218Z",
        "dateUpdated": "2026-10-29T14:19:14.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115796 (GCVE-0-2026-115796)

    Vulnerability from nvd – Published: 2026-10-23 19:45 – Updated: 2026-10-29 18:12
    VLAI
    Title
    Tenda F6 Web Management cross-site request forgery
    Summary
    A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-29 18:11 UTC
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-115796",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-29T18:11:43.400304Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-29T18:12:23.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abdullah Altamimi"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Alshalan"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Almukhalfi"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:10:13.939Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425974 | Tenda F6 Web Management cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/425974"
            },
            {
              "name": "VDB-425974 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425974/cti"
            },
            {
              "name": "CVE-2026-115796 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115796"
            },
            {
              "name": "Submit #1022074 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cross-Site Request Forgery (CWE-352)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-26T17:09:36.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cross-site request forgery",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115796",
        "datePublished": "2026-10-23T19:45:19.860Z",
        "dateReserved": "2026-10-23T14:57:43.016Z",
        "dateUpdated": "2026-10-29T18:12:23.630Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114268 (GCVE-0-2026-114268)

    Vulnerability from nvd – Published: 2026-10-21 18:45 – Updated: 2026-10-28 18:01
    VLAI
    Title
    Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow
    Summary
    A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 17:59 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/424700 vdb-entrytechnical-description
    https://vuldb.com/vuln/424700/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-114268 third-party-advisory
    https://vuldb.com/submit/1018994 third-party-advisory
    https://github.com/Tmzop/Tenda-CVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda BE3L Pro Affected: 16.03.60.62
        cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-114268",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T17:59:03.838803Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T18:01:19.275Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*"
              ],
              "product": "BE3L Pro",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.60.62"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T18:45:12.143Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-424700 | Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/424700"
            },
            {
              "name": "VDB-424700 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/424700/cti"
            },
            {
              "name": "CVE-2026-114268 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-114268"
            },
            {
              "name": "Submit #1018994 | Tenda Tenda Router BE3L Pro V16.03.60.62 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018994"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-CVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-21T09:01:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-114268",
        "datePublished": "2026-10-21T18:45:12.143Z",
        "dateReserved": "2026-10-21T06:51:52.604Z",
        "dateUpdated": "2026-10-28T18:01:19.275Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from nvd – Published: 2026-10-21 01:30 – Updated: 2026-10-28 16:21
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 16:20 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-113744",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T16:20:49.387664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:21:28.084Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-28T16:21:28.084Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-105778 (GCVE-0-2026-105778)

    Vulnerability from nvd – Published: 2026-10-06 06:45 – Updated: 2026-10-06 17:40
    VLAI
    Title
    Tenda AC5 Wifi setWifi stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-06 17:07 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC5 Affected: 02.03.01.111_multi
        cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-105778",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-06T17:07:05.050647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-06T17:40:19.337Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wifi Handler"
              ],
              "product": "AC5",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "02.03.01.111_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "raisecnull (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-06T06:45:13.774Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-413811 | Tenda AC5 Wifi setWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/413811"
            },
            {
              "name": "VDB-413811 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/413811/cti"
            },
            {
              "name": "CVE-2026-105778 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-105778"
            },
            {
              "name": "Submit #992587 | Tenda AC5 V02.03.01.111_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/992587"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/raisecnull/Tenda-AC5v3-BOF/blob/main/blog.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-05T22:40:11.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC5 Wifi setWifi stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-105778",
        "datePublished": "2026-10-06T06:45:13.774Z",
        "dateReserved": "2026-10-05T20:34:57.881Z",
        "dateUpdated": "2026-10-06T17:40:19.337Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136554 (GCVE-0-2026-136554)

    Vulnerability from cvelistv5 – Published: 2026-11-25 06:45 – Updated: 2026-11-25 06:45
    VLAI
    Title
    Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication
    Summary
    A flaw has been found in Tenda RX3 16.03.13.11_multi. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet of the component httpd. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda RX3 16.03.13.11_multi. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet of the component httpd. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.5,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:45:13.355Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443411 | Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443411"
            },
            {
              "name": "VDB-443411 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443411/cti"
            },
            {
              "name": "CVE-2026-136554 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136554"
            },
            {
              "name": "Submit #1057774 | Tenda RX3 V16.03.13.11_multi Missing Authentication for Critical Function",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057774"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/factory_reset_no_auth/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:16:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 httpd SysToolRestoreSet fromSysToolRestoreSet missing authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136554",
        "datePublished": "2026-11-25T06:45:13.355Z",
        "dateReserved": "2026-11-24T21:10:24.253Z",
        "dateUpdated": "2026-11-25T06:45:13.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136553 (GCVE-0-2026-136553)

    Vulnerability from cvelistv5 – Published: 2026-11-25 06:30 – Updated: 2026-11-25 06:30
    VLAI
    Title
    Tenda RX3 fast_setting_wifi_set improper authentication
    Summary
    A vulnerability was detected in Tenda RX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Performing a manipulation of the argument loginPwd results in improper authentication. It is possible to initiate the attack remotely. The exploit is now public and may be used.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda RX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Performing a manipulation of the argument loginPwd results in improper authentication. It is possible to initiate the attack remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:30:24.581Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443410 | Tenda RX3 fast_setting_wifi_set improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443410"
            },
            {
              "name": "VDB-443410 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443410/cti"
            },
            {
              "name": "CVE-2026-136553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136553"
            },
            {
              "name": "Submit #1057770 | Tenda RX3 V16.03.13.11_multi Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057770"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/password_change_no_verify/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 fast_setting_wifi_set improper authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136553",
        "datePublished": "2026-11-25T06:30:24.581Z",
        "dateReserved": "2026-11-24T21:10:19.599Z",
        "dateUpdated": "2026-11-25T06:30:24.581Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136552 (GCVE-0-2026-136552)

    Vulnerability from cvelistv5 – Published: 2026-11-25 06:00 – Updated: 2026-11-25 06:00
    VLAI
    Title
    Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection
    Summary
    A security vulnerability has been detected in Tenda RX3 16.03.13.11_multi. This impacts the function formSetIPv6status of the file /goform/setIPv6Status of the component multiWAN. Such manipulation of the argument remoteIP leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "multiWAN"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda RX3 16.03.13.11_multi. This impacts the function formSetIPv6status of the file /goform/setIPv6Status of the component multiWAN. Such manipulation of the argument remoteIP leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T06:00:27.450Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443409 | Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443409"
            },
            {
              "name": "VDB-443409 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443409/cti"
            },
            {
              "name": "CVE-2026-136552 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136552"
            },
            {
              "name": "Submit #1057769 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057769"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_ipv6/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:51.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 multiWAN setIPv6Status formSetIPv6status command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136552",
        "datePublished": "2026-11-25T06:00:27.450Z",
        "dateReserved": "2026-11-24T21:10:15.190Z",
        "dateUpdated": "2026-11-25T06:00:27.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136550 (GCVE-0-2026-136550)

    Vulnerability from cvelistv5 – Published: 2026-11-25 05:45 – Updated: 2026-11-25 05:45
    VLAI
    Title
    Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection
    Summary
    A weakness has been identified in Tenda RX3 16.03.13.11_multi. This affects the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. This manipulation of the argument mac causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda RX3 16.03.13.11_multi. This affects the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. This manipulation of the argument mac causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:45:18.522Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443408 | Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443408"
            },
            {
              "name": "VDB-443408 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443408/cti"
            },
            {
              "name": "CVE-2026-136550 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136550"
            },
            {
              "name": "Submit #1057768 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057768"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_mac/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 AdvSetMacMtuWan fromAdvSetMacMtuWan command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136550",
        "datePublished": "2026-11-25T05:45:18.522Z",
        "dateReserved": "2026-11-24T21:10:10.266Z",
        "dateUpdated": "2026-11-25T05:45:18.522Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136549 (GCVE-0-2026-136549)

    Vulnerability from cvelistv5 – Published: 2026-11-25 05:30 – Updated: 2026-11-25 05:30
    VLAI
    Title
    Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection
    Summary
    A security flaw has been discovered in Tenda RX3 16.03.13.11_multi. The impacted element is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda RX3 16.03.13.11_multi. The impacted element is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:30:17.472Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443407 | Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443407"
            },
            {
              "name": "VDB-443407 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443407/cti"
            },
            {
              "name": "CVE-2026-136549 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136549"
            },
            {
              "name": "Submit #1057767 | Tenda RX3 V16.03.13.11_multi OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057767"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_remoteIp/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:42.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetRemoteWebCfg formSetSafeWanWebMan command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136549",
        "datePublished": "2026-11-25T05:30:17.472Z",
        "dateReserved": "2026-11-24T21:10:04.044Z",
        "dateUpdated": "2026-11-25T05:30:17.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136548 (GCVE-0-2026-136548)

    Vulnerability from cvelistv5 – Published: 2026-11-25 05:15 – Updated: 2026-11-25 05:15
    VLAI
    Title
    Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow
    Summary
    A vulnerability was identified in Tenda RX3 16.03.13.11. The affected element is an unknown function of the file /bin/auto_discover of the component GBK-to-UTF-8 Conversion. The manipulation of the argument Hostname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "GBK-to-UTF-8 Conversion"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda RX3 16.03.13.11. The affected element is an unknown function of the file /bin/auto_discover of the component GBK-to-UTF-8 Conversion. The manipulation of the argument Hostname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:15:17.187Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443406 | Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443406"
            },
            {
              "name": "VDB-443406 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443406/cti"
            },
            {
              "name": "CVE-2026-136548 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136548"
            },
            {
              "name": "Submit #1057714 | Tenda RX3 V16.03.13.11_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057714"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/dhcp_gbk_overflow/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 GBK-to-UTF-8 Conversion auto_discover stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136548",
        "datePublished": "2026-11-25T05:15:17.187Z",
        "dateReserved": "2026-11-24T21:09:59.572Z",
        "dateUpdated": "2026-11-25T05:15:17.187Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136547 (GCVE-0-2026-136547)

    Vulnerability from cvelistv5 – Published: 2026-11-25 05:00 – Updated: 2026-11-25 05:00
    VLAI
    Title
    Tenda RX3 httpd R7WebsSecurityHandler improper authentication
    Summary
    A vulnerability was determined in Tenda RX3 16.03.13.11_multi. Impacted is the function R7WebsSecurityHandler of the component httpd. Executing a manipulation can lead to improper authentication. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeyyyfroyst (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda RX3 16.03.13.11_multi. Impacted is the function R7WebsSecurityHandler of the component httpd. Executing a manipulation can lead to improper authentication. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T05:00:21.550Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-443405 | Tenda RX3 httpd R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/443405"
            },
            {
              "name": "VDB-443405 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/443405/cti"
            },
            {
              "name": "CVE-2026-136547 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-136547"
            },
            {
              "name": "Submit #1057713 | Tenda RX3 V16.03.13.11_multi Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1057713"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/auth_bypass/detail.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T22:15:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 httpd R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-136547",
        "datePublished": "2026-11-25T05:00:21.550Z",
        "dateReserved": "2026-11-24T21:09:55.131Z",
        "dateUpdated": "2026-11-25T05:00:21.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-129258 (GCVE-0-2026-129258)

    Vulnerability from cvelistv5 – Published: 2026-11-14 14:30 – Updated: 2026-11-16 15:37
    VLAI
    Title
    Tenda AC18 Firmware Upgrade upgrade data authenticity
    Summary
    A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 15:12 UTC
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    References
    URL Tags
    https://vuldb.com/vuln/437295 vdb-entrytechnical-description
    https://vuldb.com/vuln/437295/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-129258 third-party-advisory
    https://vuldb.com/submit/1043033 third-party-advisory
    https://github.com/longqx223/Tenda-ac-18-V15.03.0… exploitpatch
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.05_multi
    Affected: 15.03.05.19 Build 6318
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-129258",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T15:12:58.266813Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:37:49.793Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Firmware Upgrade Handler"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.05_multi"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.19 Build 6318"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Longqxxixi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-14T14:30:22.937Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-437295 | Tenda AC18 Firmware Upgrade upgrade data authenticity",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/437295"
            },
            {
              "name": "VDB-437295 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/437295/cti"
            },
            {
              "name": "CVE-2026-129258 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-129258"
            },
            {
              "name": "Submit #1043033 | Tenda AC18 (AC18V1.0BR) wireless router V15.03.05.05_multi ,V15.03.05.19 build 6318  Insufficient Verification of Data Authenticity",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1043033"
            },
            {
              "tags": [
                "exploit",
                "patch"
              ],
              "url": "https://github.com/longqx223/Tenda-ac-18-V15.03.05.05-/blob/main/2026-10-19-Tenda-AC18-unsigned-firmware-update-advisory-EN.pdf"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-13T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-13T21:02:27.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Firmware Upgrade upgrade data authenticity",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-129258",
        "datePublished": "2026-11-14T14:30:22.937Z",
        "dateReserved": "2026-11-13T19:57:13.854Z",
        "dateUpdated": "2026-11-16T15:37:49.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123966 (GCVE-0-2026-123966)

    Vulnerability from cvelistv5 – Published: 2026-11-07 13:45 – Updated: 2026-11-09 22:41
    VLAI
    Title
    Tenda AC19 saveParentControlInfo heap-based overflow
    Summary
    A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 22:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-123966",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T22:40:09.150272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T22:41:45.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-07T13:45:19.423Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-432038 | Tenda AC19 saveParentControlInfo heap-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/432038"
            },
            {
              "name": "VDB-432038 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/432038/cti"
            },
            {
              "name": "CVE-2026-123966 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-123966"
            },
            {
              "name": "Submit #1035173 | Tenda AC19 V16.03.10.07 Heap-Based Buffer Overflow (CWE-122)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1035173"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-AC19-saveParentControlInfo/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-06T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-06T18:21:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 saveParentControlInfo heap-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-123966",
        "datePublished": "2026-11-07T13:45:19.423Z",
        "dateReserved": "2026-11-06T17:16:21.436Z",
        "dateUpdated": "2026-11-09T22:41:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-118238 (GCVE-0-2026-118238)

    Vulnerability from cvelistv5 – Published: 2026-10-30 15:08 – Updated: 2026-10-30 17:07
    VLAI
    Title
    CVE-2026-118238
    Summary
    The Tenda W18E web management server is vulnerable to OS command injection via the "diagnose" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 17:07 UTC
    CWE
    Impacted products
    Vendor Product Version
    Tenda W18E Affected: V16.01.0.20
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "HIGH",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-118238",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T17:07:03.133377Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T17:07:06.917Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "W18E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "V16.01.0.20"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Tenda W18E web management server is vulnerable to OS command injection via the \"diagnose\" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-30T15:08:41.752Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "url": "https://cushz.github.io/en/exploit-development/2026/10/27/hacking-routers-for-fun-and-not-profit.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2026-118238",
          "x_generator": {
            "engine": "VINCE 3.0.52",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2026-118238"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2026-118238",
        "datePublished": "2026-10-30T15:08:41.752Z",
        "dateReserved": "2026-10-27T19:49:03.088Z",
        "dateUpdated": "2026-10-30T17:07:06.917Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115797 (GCVE-0-2026-115797)

    Vulnerability from cvelistv5 – Published: 2026-10-23 20:00 – Updated: 2026-10-29 14:19
    VLAI
    Title
    Tenda F6 Web Management cleartext transmission
    Summary
    A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-29 14:18 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    • CWE-310 - Cryptographic Issues
    References
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-115797",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-29T14:18:52.852412Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-29T14:19:14.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abdullah Altamimi"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Alshalan"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Almukhalfi"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 2.6,
                "vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-310",
                  "description": "Cryptographic Issues",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:10:39.242Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425975 | Tenda F6 Web Management cleartext transmission",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/425975"
            },
            {
              "name": "VDB-425975 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425975/cti"
            },
            {
              "name": "CVE-2026-115797 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115797"
            },
            {
              "name": "Submit #1022076 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cleartext Transmission of Sensitive Information (CWE-319)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022076"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/edit/main/02-Cleartext_Transmission.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-26T17:12:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cleartext transmission",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115797",
        "datePublished": "2026-10-23T20:00:16.370Z",
        "dateReserved": "2026-10-23T14:57:47.218Z",
        "dateUpdated": "2026-10-29T14:19:14.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115796 (GCVE-0-2026-115796)

    Vulnerability from cvelistv5 – Published: 2026-10-23 19:45 – Updated: 2026-10-29 18:12
    VLAI
    Title
    Tenda F6 Web Management cross-site request forgery
    Summary
    A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-29 18:11 UTC
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-115796",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-29T18:11:43.400304Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-29T18:12:23.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abdullah Altamimi"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Alshalan"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Muhannad Almukhalfi"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:10:13.939Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425974 | Tenda F6 Web Management cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/425974"
            },
            {
              "name": "VDB-425974 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425974/cti"
            },
            {
              "name": "CVE-2026-115796 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115796"
            },
            {
              "name": "Submit #1022074 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cross-Site Request Forgery (CWE-352)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-26T17:09:36.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cross-site request forgery",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115796",
        "datePublished": "2026-10-23T19:45:19.860Z",
        "dateReserved": "2026-10-23T14:57:43.016Z",
        "dateUpdated": "2026-10-29T18:12:23.630Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114268 (GCVE-0-2026-114268)

    Vulnerability from cvelistv5 – Published: 2026-10-21 18:45 – Updated: 2026-10-28 18:01
    VLAI
    Title
    Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow
    Summary
    A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 17:59 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/424700 vdb-entrytechnical-description
    https://vuldb.com/vuln/424700/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-114268 third-party-advisory
    https://vuldb.com/submit/1018994 third-party-advisory
    https://github.com/Tmzop/Tenda-CVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda BE3L Pro Affected: 16.03.60.62
        cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-114268",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T17:59:03.838803Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T18:01:19.275Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*"
              ],
              "product": "BE3L Pro",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.60.62"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T18:45:12.143Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-424700 | Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/424700"
            },
            {
              "name": "VDB-424700 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/424700/cti"
            },
            {
              "name": "CVE-2026-114268 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-114268"
            },
            {
              "name": "Submit #1018994 | Tenda Tenda Router BE3L Pro V16.03.60.62 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018994"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-CVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-21T09:01:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-114268",
        "datePublished": "2026-10-21T18:45:12.143Z",
        "dateReserved": "2026-10-21T06:51:52.604Z",
        "dateUpdated": "2026-10-28T18:01:19.275Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from cvelistv5 – Published: 2026-10-21 01:30 – Updated: 2026-10-28 16:21
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 16:20 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-113744",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T16:20:49.387664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:21:28.084Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-28T16:21:28.084Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-105778 (GCVE-0-2026-105778)

    Vulnerability from cvelistv5 – Published: 2026-10-06 06:45 – Updated: 2026-10-06 17:40
    VLAI
    Title
    Tenda AC5 Wifi setWifi stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-06 17:07 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC5 Affected: 02.03.01.111_multi
        cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-105778",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-06T17:07:05.050647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-06T17:40:19.337Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wifi Handler"
              ],
              "product": "AC5",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "02.03.01.111_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "raisecnull (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-06T06:45:13.774Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-413811 | Tenda AC5 Wifi setWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/413811"
            },
            {
              "name": "VDB-413811 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/413811/cti"
            },
            {
              "name": "CVE-2026-105778 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-105778"
            },
            {
              "name": "Submit #992587 | Tenda AC5 V02.03.01.111_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/992587"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/raisecnull/Tenda-AC5v3-BOF/blob/main/blog.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-05T22:40:11.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC5 Wifi setWifi stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-105778",
        "datePublished": "2026-10-06T06:45:13.774Z",
        "dateReserved": "2026-10-05T20:34:57.881Z",
        "dateUpdated": "2026-10-06T17:40:19.337Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }