Search

Find a vulnerability

Search criteria

    10 vulnerabilities by python-hyper

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-11-10 12:50
    VLAI CISA
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens Calibre Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Calibre ICE Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens COMOS Walkinside Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens gDAP (gPROMS Digital Application Platform) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Pathway to Learning Engineering Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PAVE360 Automotive 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Polarion Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Process Preparation X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Project Server Web Administration Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC BRAUMAT Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC Profiling Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC SISTAR Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Companion Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.20 Affected: 0 , < V3.20 P17.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.21 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified for Industrial Edge Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified SIQENCE Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC V7/V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Simcenter Executable Digital Twin Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Simcenter Studio Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Solid Edge Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter Share Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2412 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2506 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2512 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2606 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens User Management Component (UMC) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Xpedition Designer Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Xpedition Enterprise Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM APE1808 Affected: 0 , < * (custom)
    Create a notification for this product.
    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "Calibre",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Calibre ICE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "gDAP (gPROMS Digital Application Platform)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20 P17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-10T12:50:00.309Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-10T12:50:00.309Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59980 (GCVE-0-2026-59980)

    Vulnerability from nvd – Published: 2026-09-23 22:07 – Updated: 2026-09-24 13:25
    VLAI
    Title
    hpack: Unbounded variable integer decoding can cause run-away computation on malformed input
    Summary
    hpack is an HTTP/2 Header Encoding for Python. Prior to version 4.2.0, unbounded variable integer decoding can cause run-away computation on malformed input leading to O(n^2) runtime, effectively blocking further processing with large enough unsanitized input. A fix is available in python-hyper/hpack v4.2.0 to restricted variable integer decoding to uint32 to prevent run-away computation. As a workaround, sanitize input to hpack decoder for long sequences of `0xFF` values to prevent malicious use.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 13:24 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    python-hyper hpack Affected: < 4.2.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59980",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T13:24:31.887152Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T13:25:08.900Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "hpack",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "hpack is an HTTP/2 Header Encoding for Python. Prior to version 4.2.0, unbounded variable integer decoding can cause run-away computation on malformed input leading to O(n^2) runtime, effectively blocking further processing with large enough unsanitized input. A fix is available in python-hyper/hpack v4.2.0 to restricted variable integer decoding to uint32 to prevent run-away computation. As a workaround, sanitize input to hpack decoder for long sequences of `0xFF` values to prevent malicious use."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-23T22:07:35.095Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/hpack/security/advisories/GHSA-8v8h-hg4w-mvq2",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/hpack/security/advisories/GHSA-8v8h-hg4w-mvq2"
            },
            {
              "name": "https://github.com/python-hyper/hpack/commit/8cfb02c547740e16dbfe7aba77bad84b297cec2c",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/hpack/commit/8cfb02c547740e16dbfe7aba77bad84b297cec2c"
            },
            {
              "name": "https://cs.opensource.google/go/x/net/+/master:http2/hpack/hpack.go;l=468;drc=8e2b117aee74f6b86c207a808b0255de45c0a18a",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cs.opensource.google/go/x/net/+/master:http2/hpack/hpack.go;l=468;drc=8e2b117aee74f6b86c207a808b0255de45c0a18a"
            },
            {
              "name": "https://docs.rs/http2/0.5.19/src/http2/hpack/decoder.rs.html#403",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://docs.rs/http2/0.5.19/src/http2/hpack/decoder.rs.html#403"
            }
          ],
          "source": {
            "advisory": "GHSA-8v8h-hg4w-mvq2",
            "discovery": "UNKNOWN"
          },
          "title": "hpack: Unbounded variable integer decoding can cause run-away computation on malformed input"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-59980",
        "datePublished": "2026-09-23T22:07:35.095Z",
        "dateReserved": "2026-07-07T19:41:00.004Z",
        "dateUpdated": "2026-09-24T13:25:08.900Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71554 (GCVE-0-2026-71554)

    Vulnerability from nvd – Published: 2026-08-06 21:46 – Updated: 2026-08-08 02:49
    VLAI
    Title
    h2: Duplicate Host header could facilitate request smuggling
    Summary
    h2 is a pure-Python implementation of a HTTP/2 protocol stack. Versions up to and including 4.4.0 accept request header blocks containing more than one Host header, and forward every Host header to the consuming application. Where the consumer downgrades HTTP/2 to HTTP/1.1, the resulting request carries two Host header lines, providing a request smuggling primitive. This issue is fixed in version 4.4.1.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-08 02:49 UTC
    CWE
    • CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')
    References
    Impacted products
    Vendor Product Version
    python-hyper h2 Affected: < 4.4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71554",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-08T02:49:21.263516Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-08T02:49:30.505Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h2",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h2 is a pure-Python implementation of a HTTP/2 protocol stack. Versions up to and including 4.4.0 accept request header blocks containing more than one Host header, and forward every Host header to the consuming application. Where the consumer downgrades HTTP/2 to HTTP/1.1, the resulting request carries two Host header lines, providing a request smuggling primitive. This issue is fixed in version 4.4.1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-444",
                  "description": "CWE-444: Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-06T21:46:43.057Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h2/security/advisories/GHSA-6hr6-w5qg-qmwg",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h2/security/advisories/GHSA-6hr6-w5qg-qmwg"
            },
            {
              "name": "https://github.com/python-hyper/h2/commit/292a40829feefda98c8509dcdbbb4a57af9bd6a6",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h2/commit/292a40829feefda98c8509dcdbbb4a57af9bd6a6"
            }
          ],
          "source": {
            "advisory": "GHSA-6hr6-w5qg-qmwg",
            "discovery": "UNKNOWN"
          },
          "title": "h2: Duplicate Host header could facilitate request smuggling"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-71554",
        "datePublished": "2026-08-06T21:46:43.057Z",
        "dateReserved": "2026-08-06T21:24:15.376Z",
        "dateUpdated": "2026-08-08T02:49:30.505Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-57804 (GCVE-0-2025-57804)

    Vulnerability from nvd – Published: 2025-08-25 21:04 – Updated: 2025-11-03 18:13
    VLAI
    Title
    h2 allows HTTP Request Smuggling due to illegal characters in headers
    Summary
    h2 is a pure-Python implementation of a HTTP/2 protocol stack. Prior to version 4.3.0, an HTTP/2 request splitting vulnerability allows attackers to perform request smuggling attacks by injecting CRLF characters into headers. This occurs when servers downgrade HTTP/2 requests to HTTP/1.1 without properly validating header names/values, enabling attackers to manipulate request boundaries and bypass security controls. This issue has been patched in version 4.3.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-26 19:14 UTC
    CWE
    • CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
    Impacted products
    Vendor Product Version
    python-hyper h2 Affected: < 4.3.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57804",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-26T19:14:14.359281Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-26T19:14:49.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T18:13:44.839Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://lists.debian.org/debian-lts-announce/2025/09/msg00004.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h2",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.3.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h2 is a pure-Python implementation of a HTTP/2 protocol stack. Prior to version 4.3.0, an HTTP/2 request splitting vulnerability allows attackers to perform request smuggling attacks by injecting CRLF characters into headers. This occurs when servers downgrade HTTP/2 requests to HTTP/1.1 without properly validating header names/values, enabling attackers to manipulate request boundaries and bypass security controls. This issue has been patched in version 4.3.0."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-93",
                  "description": "CWE-93: Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-25T21:04:52.642Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h2/security/advisories/GHSA-847f-9342-265h",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h2/security/advisories/GHSA-847f-9342-265h"
            },
            {
              "name": "https://github.com/python-hyper/h2/commit/035e9899f95e3709af098f578bfc3cd302298e3a",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h2/commit/035e9899f95e3709af098f578bfc3cd302298e3a"
            }
          ],
          "source": {
            "advisory": "GHSA-847f-9342-265h",
            "discovery": "UNKNOWN"
          },
          "title": "h2 allows HTTP Request Smuggling due to illegal characters in headers"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2025-57804",
        "datePublished": "2025-08-25T21:04:52.642Z",
        "dateReserved": "2025-08-20T14:30:35.009Z",
        "dateUpdated": "2025-11-03T18:13:44.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43859 (GCVE-0-2025-43859)

    Vulnerability from nvd – Published: 2025-04-24 18:15 – Updated: 2025-04-24 19:02
    VLAI
    Title
    h11 accepts some malformed Chunked-Encoding bodies
    Summary
    h11 is a Python implementation of HTTP/1.1. Prior to version 0.16.0, a leniency in h11's parsing of line terminators in chunked-coding message bodies can lead to request smuggling vulnerabilities under certain conditions. This issue has been patched in version 0.16.0. Since exploitation requires the combination of buggy h11 with a buggy (reverse) proxy, fixing either component is sufficient to mitigate this issue.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-24 19:02 UTC
    CWE
    • CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')
    References
    Impacted products
    Vendor Product Version
    python-hyper h11 Affected: < 0.16.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43859",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-24T19:02:05.000674Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-24T19:02:45.130Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h11",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 0.16.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h11 is a Python implementation of HTTP/1.1. Prior to version 0.16.0, a leniency in h11\u0027s parsing of line terminators in chunked-coding message bodies can lead to request smuggling vulnerabilities under certain conditions. This issue has been patched in version 0.16.0. Since exploitation requires the combination of buggy h11 with a buggy (reverse) proxy, fixing either component is sufficient to mitigate this issue."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-444",
                  "description": "CWE-444: Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-24T18:15:53.328Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h11/security/advisories/GHSA-vqfr-h8mv-ghfj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h11/security/advisories/GHSA-vqfr-h8mv-ghfj"
            },
            {
              "name": "https://github.com/python-hyper/h11/commit/114803a29ce50116dc47951c690ad4892b1a36ed",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h11/commit/114803a29ce50116dc47951c690ad4892b1a36ed"
            }
          ],
          "source": {
            "advisory": "GHSA-vqfr-h8mv-ghfj",
            "discovery": "UNKNOWN"
          },
          "title": "h11 accepts some malformed Chunked-Encoding bodies"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2025-43859",
        "datePublished": "2025-04-24T18:15:53.328Z",
        "dateReserved": "2025-04-17T20:07:08.556Z",
        "dateUpdated": "2025-04-24T19:02:45.130Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-11-10 12:50
    VLAI CISA
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens Calibre Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Calibre ICE Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens COMOS Walkinside Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens gDAP (gPROMS Digital Application Platform) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Pathway to Learning Engineering Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PAVE360 Automotive 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Polarion Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Process Preparation X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Project Server Web Administration Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC BRAUMAT Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC Profiling Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC SISTAR Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Companion Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.20 Affected: 0 , < V3.20 P17.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.21 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified for Industrial Edge Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified SIQENCE Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC V7/V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Simcenter Executable Digital Twin Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Simcenter Studio Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Solid Edge Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter Share Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2412 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2506 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2512 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Teamcenter V2606 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens User Management Component (UMC) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Xpedition Designer Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Xpedition Enterprise Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM APE1808 Affected: 0 , < * (custom)
    Create a notification for this product.
    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "Calibre",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Calibre ICE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "gDAP (gPROMS Digital Application Platform)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20 P17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-10T12:50:00.309Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-10T12:50:00.309Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59980 (GCVE-0-2026-59980)

    Vulnerability from cvelistv5 – Published: 2026-09-23 22:07 – Updated: 2026-09-24 13:25
    VLAI
    Title
    hpack: Unbounded variable integer decoding can cause run-away computation on malformed input
    Summary
    hpack is an HTTP/2 Header Encoding for Python. Prior to version 4.2.0, unbounded variable integer decoding can cause run-away computation on malformed input leading to O(n^2) runtime, effectively blocking further processing with large enough unsanitized input. A fix is available in python-hyper/hpack v4.2.0 to restricted variable integer decoding to uint32 to prevent run-away computation. As a workaround, sanitize input to hpack decoder for long sequences of `0xFF` values to prevent malicious use.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 13:24 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    python-hyper hpack Affected: < 4.2.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59980",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T13:24:31.887152Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T13:25:08.900Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "hpack",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "hpack is an HTTP/2 Header Encoding for Python. Prior to version 4.2.0, unbounded variable integer decoding can cause run-away computation on malformed input leading to O(n^2) runtime, effectively blocking further processing with large enough unsanitized input. A fix is available in python-hyper/hpack v4.2.0 to restricted variable integer decoding to uint32 to prevent run-away computation. As a workaround, sanitize input to hpack decoder for long sequences of `0xFF` values to prevent malicious use."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-23T22:07:35.095Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/hpack/security/advisories/GHSA-8v8h-hg4w-mvq2",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/hpack/security/advisories/GHSA-8v8h-hg4w-mvq2"
            },
            {
              "name": "https://github.com/python-hyper/hpack/commit/8cfb02c547740e16dbfe7aba77bad84b297cec2c",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/hpack/commit/8cfb02c547740e16dbfe7aba77bad84b297cec2c"
            },
            {
              "name": "https://cs.opensource.google/go/x/net/+/master:http2/hpack/hpack.go;l=468;drc=8e2b117aee74f6b86c207a808b0255de45c0a18a",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cs.opensource.google/go/x/net/+/master:http2/hpack/hpack.go;l=468;drc=8e2b117aee74f6b86c207a808b0255de45c0a18a"
            },
            {
              "name": "https://docs.rs/http2/0.5.19/src/http2/hpack/decoder.rs.html#403",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://docs.rs/http2/0.5.19/src/http2/hpack/decoder.rs.html#403"
            }
          ],
          "source": {
            "advisory": "GHSA-8v8h-hg4w-mvq2",
            "discovery": "UNKNOWN"
          },
          "title": "hpack: Unbounded variable integer decoding can cause run-away computation on malformed input"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-59980",
        "datePublished": "2026-09-23T22:07:35.095Z",
        "dateReserved": "2026-07-07T19:41:00.004Z",
        "dateUpdated": "2026-09-24T13:25:08.900Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71554 (GCVE-0-2026-71554)

    Vulnerability from cvelistv5 – Published: 2026-08-06 21:46 – Updated: 2026-08-08 02:49
    VLAI
    Title
    h2: Duplicate Host header could facilitate request smuggling
    Summary
    h2 is a pure-Python implementation of a HTTP/2 protocol stack. Versions up to and including 4.4.0 accept request header blocks containing more than one Host header, and forward every Host header to the consuming application. Where the consumer downgrades HTTP/2 to HTTP/1.1, the resulting request carries two Host header lines, providing a request smuggling primitive. This issue is fixed in version 4.4.1.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-08 02:49 UTC
    CWE
    • CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')
    References
    Impacted products
    Vendor Product Version
    python-hyper h2 Affected: < 4.4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71554",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-08T02:49:21.263516Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-08T02:49:30.505Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h2",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h2 is a pure-Python implementation of a HTTP/2 protocol stack. Versions up to and including 4.4.0 accept request header blocks containing more than one Host header, and forward every Host header to the consuming application. Where the consumer downgrades HTTP/2 to HTTP/1.1, the resulting request carries two Host header lines, providing a request smuggling primitive. This issue is fixed in version 4.4.1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-444",
                  "description": "CWE-444: Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-06T21:46:43.057Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h2/security/advisories/GHSA-6hr6-w5qg-qmwg",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h2/security/advisories/GHSA-6hr6-w5qg-qmwg"
            },
            {
              "name": "https://github.com/python-hyper/h2/commit/292a40829feefda98c8509dcdbbb4a57af9bd6a6",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h2/commit/292a40829feefda98c8509dcdbbb4a57af9bd6a6"
            }
          ],
          "source": {
            "advisory": "GHSA-6hr6-w5qg-qmwg",
            "discovery": "UNKNOWN"
          },
          "title": "h2: Duplicate Host header could facilitate request smuggling"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-71554",
        "datePublished": "2026-08-06T21:46:43.057Z",
        "dateReserved": "2026-08-06T21:24:15.376Z",
        "dateUpdated": "2026-08-08T02:49:30.505Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-57804 (GCVE-0-2025-57804)

    Vulnerability from cvelistv5 – Published: 2025-08-25 21:04 – Updated: 2025-11-03 18:13
    VLAI
    Title
    h2 allows HTTP Request Smuggling due to illegal characters in headers
    Summary
    h2 is a pure-Python implementation of a HTTP/2 protocol stack. Prior to version 4.3.0, an HTTP/2 request splitting vulnerability allows attackers to perform request smuggling attacks by injecting CRLF characters into headers. This occurs when servers downgrade HTTP/2 requests to HTTP/1.1 without properly validating header names/values, enabling attackers to manipulate request boundaries and bypass security controls. This issue has been patched in version 4.3.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-26 19:14 UTC
    CWE
    • CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
    Impacted products
    Vendor Product Version
    python-hyper h2 Affected: < 4.3.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57804",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-26T19:14:14.359281Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-26T19:14:49.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T18:13:44.839Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://lists.debian.org/debian-lts-announce/2025/09/msg00004.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h2",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.3.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h2 is a pure-Python implementation of a HTTP/2 protocol stack. Prior to version 4.3.0, an HTTP/2 request splitting vulnerability allows attackers to perform request smuggling attacks by injecting CRLF characters into headers. This occurs when servers downgrade HTTP/2 requests to HTTP/1.1 without properly validating header names/values, enabling attackers to manipulate request boundaries and bypass security controls. This issue has been patched in version 4.3.0."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-93",
                  "description": "CWE-93: Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-25T21:04:52.642Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h2/security/advisories/GHSA-847f-9342-265h",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h2/security/advisories/GHSA-847f-9342-265h"
            },
            {
              "name": "https://github.com/python-hyper/h2/commit/035e9899f95e3709af098f578bfc3cd302298e3a",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h2/commit/035e9899f95e3709af098f578bfc3cd302298e3a"
            }
          ],
          "source": {
            "advisory": "GHSA-847f-9342-265h",
            "discovery": "UNKNOWN"
          },
          "title": "h2 allows HTTP Request Smuggling due to illegal characters in headers"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2025-57804",
        "datePublished": "2025-08-25T21:04:52.642Z",
        "dateReserved": "2025-08-20T14:30:35.009Z",
        "dateUpdated": "2025-11-03T18:13:44.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43859 (GCVE-0-2025-43859)

    Vulnerability from cvelistv5 – Published: 2025-04-24 18:15 – Updated: 2025-04-24 19:02
    VLAI
    Title
    h11 accepts some malformed Chunked-Encoding bodies
    Summary
    h11 is a Python implementation of HTTP/1.1. Prior to version 0.16.0, a leniency in h11's parsing of line terminators in chunked-coding message bodies can lead to request smuggling vulnerabilities under certain conditions. This issue has been patched in version 0.16.0. Since exploitation requires the combination of buggy h11 with a buggy (reverse) proxy, fixing either component is sufficient to mitigate this issue.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-24 19:02 UTC
    CWE
    • CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')
    References
    Impacted products
    Vendor Product Version
    python-hyper h11 Affected: < 0.16.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43859",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-24T19:02:05.000674Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-24T19:02:45.130Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "h11",
              "vendor": "python-hyper",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 0.16.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "h11 is a Python implementation of HTTP/1.1. Prior to version 0.16.0, a leniency in h11\u0027s parsing of line terminators in chunked-coding message bodies can lead to request smuggling vulnerabilities under certain conditions. This issue has been patched in version 0.16.0. Since exploitation requires the combination of buggy h11 with a buggy (reverse) proxy, fixing either component is sufficient to mitigate this issue."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-444",
                  "description": "CWE-444: Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-24T18:15:53.328Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/python-hyper/h11/security/advisories/GHSA-vqfr-h8mv-ghfj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/python-hyper/h11/security/advisories/GHSA-vqfr-h8mv-ghfj"
            },
            {
              "name": "https://github.com/python-hyper/h11/commit/114803a29ce50116dc47951c690ad4892b1a36ed",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/python-hyper/h11/commit/114803a29ce50116dc47951c690ad4892b1a36ed"
            }
          ],
          "source": {
            "advisory": "GHSA-vqfr-h8mv-ghfj",
            "discovery": "UNKNOWN"
          },
          "title": "h11 accepts some malformed Chunked-Encoding bodies"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2025-43859",
        "datePublished": "2025-04-24T18:15:53.328Z",
        "dateReserved": "2025-04-17T20:07:08.556Z",
        "dateUpdated": "2025-04-24T19:02:45.130Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }