Search

Find a vulnerability

Search criteria

    8 vulnerabilities by hms-networks

    CVE-2024-23767 (GCVE-0-2024-23767)

    Vulnerability from nvd – Published: 2024-06-26 00:00 – Updated: 2024-08-01 23:13
    VLAI
    Summary
    An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device's network configurations.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 18:14 UTC
    CWE
    • n/a
    • CWE-287 - Improper Authentication
    Impacted products
    Vendor Product Version
    hms-networks anybus_x-gateway_ab7832-f Affected: 3.29.01
        cpe:2.3:o:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*
    Create a notification for this product.
    hms-networks anybus_x-gateway_ab7832-f Unknown: 0 , < * (custom)
        cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "status": "affected",
                    "version": "3.29.01"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unknown",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-23767",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T18:14:08.198256Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-287",
                    "description": "CWE-287 Improper Authentication",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-09T18:26:07.088Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/claire-lex/anybus-hicp/blob/main/hicp_config.py"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:13:07.335Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device\u0027s network configurations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T20:57:34.353Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-23767",
        "datePublished": "2024-06-26T00:00:00.000Z",
        "dateReserved": "2024-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-01T23:13:07.335Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-23766 (GCVE-0-2024-23766)

    Vulnerability from nvd – Published: 2024-06-26 00:00 – Updated: 2025-03-13 18:29
    VLAI
    Summary
    An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-27 18:33 UTC
    CWE
    • n/a
    • CWE-598 - Use of GET Request Method With Sensitive Query Strings
    Impacted products
    Vendor Product Version
    hms-networks anybus_x-gateway_ab7832-f3 Affected: 0 , < * (custom)
        cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f3",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-23766",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-27T18:33:51.318160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-598",
                    "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-13T18:29:11.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:13:07.259Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T20:50:23.197Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-23766",
        "datePublished": "2024-06-26T00:00:00.000Z",
        "dateReserved": "2024-01-22T00:00:00.000Z",
        "dateUpdated": "2025-03-13T18:29:11.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33214 (GCVE-0-2021-33214)

    Vulnerability from nvd – Published: 2021-07-09 18:03 – Updated: 2024-08-03 23:42
    VLAI
    Summary
    In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:20.270Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.bishopfox.com/advisories"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ewon.biz/about-us/security"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-17T18:42:34.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.bishopfox.com/advisories"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ewon.biz/about-us/security"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33214",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://labs.bishopfox.com/advisories",
                  "refsource": "MISC",
                  "url": "https://labs.bishopfox.com/advisories"
                },
                {
                  "name": "https://www.ewon.biz/about-us/security",
                  "refsource": "MISC",
                  "url": "https://www.ewon.biz/about-us/security"
                },
                {
                  "name": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher",
                  "refsource": "MISC",
                  "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
                },
                {
                  "name": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4",
                  "refsource": "MISC",
                  "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
                },
                {
                  "name": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4",
                  "refsource": "MISC",
                  "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33214",
        "datePublished": "2021-07-09T18:03:44.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:42:20.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-14498 (GCVE-0-2020-14498)

    Vulnerability from nvd – Published: 2020-08-26 13:30 – Updated: 2026-09-10 17:10
    VLAI
    Title
    HMS Industrial Networks AB eCatcher Stack-based Buffer Overflow
    Summary
    HMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    HMS Industrial Networks AB eCatcher Affected: 0 , < 6.5.5 (custom)
    Unaffected: 6.5.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:46:34.660Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.hms-networks.com/cybersecurity/security-advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "eCatcher",
              "vendor": "HMS Industrial Networks AB",
              "versions": [
                {
                  "lessThan": "6.5.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.5.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Sharon Brizinov of Claroty reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eHMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.\u003c/p\u003e"
                }
              ],
              "value": "HMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T17:10:56.825Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-210-03"
            },
            {
              "url": "https://www.hms-networks.com/cybersecurity/security-advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\n\u003c/p\u003e\u003cp\u003eHMS recommends users update eCatcher to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ewon.biz/technical-support/pages/all-downloads\"\u003eVersion 6.5.5 or later\u003c/a\u003e. \u003c/p\u003e\u003cp\u003eFor more information, see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.hms-networks.com/cybersecurity\"\u003eHMS advisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "HMS recommends users update eCatcher to  Version 6.5.5 or later https://ewon.biz/technical-support/pages/all-downloads . \n\nFor more information, see the  HMS advisory https://www.hms-networks.com/cybersecurity ."
            }
          ],
          "source": {
            "advisory": "ICSA-20-210-03",
            "discovery": "EXTERNAL"
          },
          "title": "HMS Industrial Networks AB eCatcher Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-14498",
              "STATE": "PUBLIC",
              "TITLE": "HMS Industrial Networks AB eCatcher Vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "eCatcher",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "6.5.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "HMS Industrial Networks AB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov of Claroty reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HMS Industrial Networks AB eCatcher all versions prior to 6.5.5. The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "HMS recommends users update eCatcher to Version 6.5.5 or later."
              }
            ],
            "source": {
              "advisory": "ICSA-20-210-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-14498",
        "datePublished": "2020-08-26T13:30:01.000Z",
        "dateReserved": "2020-06-19T00:00:00.000Z",
        "dateUpdated": "2026-09-10T17:10:56.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-23767 (GCVE-0-2024-23767)

    Vulnerability from cvelistv5 – Published: 2024-06-26 00:00 – Updated: 2024-08-01 23:13
    VLAI
    Summary
    An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device's network configurations.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 18:14 UTC
    CWE
    • n/a
    • CWE-287 - Improper Authentication
    Impacted products
    Vendor Product Version
    hms-networks anybus_x-gateway_ab7832-f Affected: 3.29.01
        cpe:2.3:o:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*
    Create a notification for this product.
    hms-networks anybus_x-gateway_ab7832-f Unknown: 0 , < * (custom)
        cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "status": "affected",
                    "version": "3.29.01"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unknown",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-23767",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T18:14:08.198256Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-287",
                    "description": "CWE-287 Improper Authentication",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-09T18:26:07.088Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/claire-lex/anybus-hicp/blob/main/hicp_config.py"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:13:07.335Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device\u0027s network configurations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T20:57:34.353Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-23767",
        "datePublished": "2024-06-26T00:00:00.000Z",
        "dateReserved": "2024-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-01T23:13:07.335Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-23766 (GCVE-0-2024-23766)

    Vulnerability from cvelistv5 – Published: 2024-06-26 00:00 – Updated: 2025-03-13 18:29
    VLAI
    Summary
    An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-27 18:33 UTC
    CWE
    • n/a
    • CWE-598 - Use of GET Request Method With Sensitive Query Strings
    Impacted products
    Vendor Product Version
    hms-networks anybus_x-gateway_ab7832-f3 Affected: 0 , < * (custom)
        cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f3",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-23766",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-27T18:33:51.318160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-598",
                    "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-13T18:29:11.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:13:07.259Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T20:50:23.197Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-23766",
        "datePublished": "2024-06-26T00:00:00.000Z",
        "dateReserved": "2024-01-22T00:00:00.000Z",
        "dateUpdated": "2025-03-13T18:29:11.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33214 (GCVE-0-2021-33214)

    Vulnerability from cvelistv5 – Published: 2021-07-09 18:03 – Updated: 2024-08-03 23:42
    VLAI
    Summary
    In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:20.270Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.bishopfox.com/advisories"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ewon.biz/about-us/security"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-17T18:42:34.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.bishopfox.com/advisories"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ewon.biz/about-us/security"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33214",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of normal system operation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://labs.bishopfox.com/advisories",
                  "refsource": "MISC",
                  "url": "https://labs.bishopfox.com/advisories"
                },
                {
                  "name": "https://www.ewon.biz/about-us/security",
                  "refsource": "MISC",
                  "url": "https://www.ewon.biz/about-us/security"
                },
                {
                  "name": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher",
                  "refsource": "MISC",
                  "url": "https://www.ewon.biz/technical-support/pages/talk2m/talk2m-tools/talk2m-ecatcher"
                },
                {
                  "name": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4",
                  "refsource": "MISC",
                  "url": "https://cdn.hms-networks.com/docs/librariesprovider6/cybersecurity/hms-security-advisory-2021-07-09-001---ewon-ecatcher.pdf?sfvrsn=b37418d7_4"
                },
                {
                  "name": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4",
                  "refsource": "MISC",
                  "url": "https://labs.bishopfox.com/advisories/ecatcher-desktop-version-6.6.4"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33214",
        "datePublished": "2021-07-09T18:03:44.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:42:20.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-14498 (GCVE-0-2020-14498)

    Vulnerability from cvelistv5 – Published: 2020-08-26 13:30 – Updated: 2026-09-10 17:10
    VLAI
    Title
    HMS Industrial Networks AB eCatcher Stack-based Buffer Overflow
    Summary
    HMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    HMS Industrial Networks AB eCatcher Affected: 0 , < 6.5.5 (custom)
    Unaffected: 6.5.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:46:34.660Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.hms-networks.com/cybersecurity/security-advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "eCatcher",
              "vendor": "HMS Industrial Networks AB",
              "versions": [
                {
                  "lessThan": "6.5.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "6.5.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Sharon Brizinov of Claroty reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eHMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.\u003c/p\u003e"
                }
              ],
              "value": "HMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T17:10:56.825Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-210-03"
            },
            {
              "url": "https://www.hms-networks.com/cybersecurity/security-advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\n\u003c/p\u003e\u003cp\u003eHMS recommends users update eCatcher to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ewon.biz/technical-support/pages/all-downloads\"\u003eVersion 6.5.5 or later\u003c/a\u003e. \u003c/p\u003e\u003cp\u003eFor more information, see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.hms-networks.com/cybersecurity\"\u003eHMS advisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "HMS recommends users update eCatcher to  Version 6.5.5 or later https://ewon.biz/technical-support/pages/all-downloads . \n\nFor more information, see the  HMS advisory https://www.hms-networks.com/cybersecurity ."
            }
          ],
          "source": {
            "advisory": "ICSA-20-210-03",
            "discovery": "EXTERNAL"
          },
          "title": "HMS Industrial Networks AB eCatcher Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-14498",
              "STATE": "PUBLIC",
              "TITLE": "HMS Industrial Networks AB eCatcher Vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "eCatcher",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "6.5.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "HMS Industrial Networks AB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov of Claroty reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HMS Industrial Networks AB eCatcher all versions prior to 6.5.5. The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "HMS recommends users update eCatcher to Version 6.5.5 or later."
              }
            ],
            "source": {
              "advisory": "ICSA-20-210-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-14498",
        "datePublished": "2020-08-26T13:30:01.000Z",
        "dateReserved": "2020-06-19T00:00:00.000Z",
        "dateUpdated": "2026-09-10T17:10:56.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }