CVE-2024-6796 (GCVE-0-2024-6796)
Vulnerability from nvd – Published: 2024-09-09 19:28 – Updated: 2024-09-09 20:08
VLAI
EPSS
VEX
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-09 19:51 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Baxter | Connex Health Portal |
Affected:
0 , < 8/30/2024
(date)
|
|
| hillrom | connex_health_portal |
Affected:
0 , < 8.30.2024
(custom)
cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "connex_health_portal",
"vendor": "hillrom",
"versions": [
{
"lessThan": "8.30.2024",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6796",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T19:51:44.387310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T20:08:22.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Connex Health Portal",
"vendor": "Baxter",
"versions": [
{
"lessThan": "8/30/2024",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content.\u0026nbsp;"
}
],
"value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T19:28:30.647Z",
"orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"shortName": "Baxter"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\n\n\u003cbr\u003e"
}
],
"value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Vulnerability in Baxter Connex Health Portal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"assignerShortName": "Baxter",
"cveId": "CVE-2024-6796",
"datePublished": "2024-09-09T19:28:30.647Z",
"dateReserved": "2024-07-16T17:54:05.755Z",
"dateUpdated": "2024-09-09T20:08:22.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6795 (GCVE-0-2024-6795)
Vulnerability from nvd – Published: 2024-09-09 19:24 – Updated: 2024-09-09 20:08
VLAI
EPSS
VEX
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.
An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content
and/or perform administrative operations including shutting down the database.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-09 20:04 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Baxter | Connex Health Portal |
Affected:
0 , < 8/30/2024
(date)
|
|
| hillrom | connex_health_portal |
Affected:
0 , < 8.30.2024
(custom)
cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "connex_health_portal",
"vendor": "hillrom",
"versions": [
{
"lessThan": "8.30.2024",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6795",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T20:04:42.779977Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T20:08:01.134Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Connex Health Portal",
"vendor": "Baxter",
"versions": [
{
"lessThan": "8/30/2024",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u0026nbsp;\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
}
],
"value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u00a0\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
}
],
"impacts": [
{
"capecId": "CAPEC-23",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-23 File Content Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T19:24:01.776Z",
"orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"shortName": "Baxter"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\u003cbr\u003e"
}
],
"value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Vulnerability in Baxter Connex Health Portal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"assignerShortName": "Baxter",
"cveId": "CVE-2024-6795",
"datePublished": "2024-09-09T19:24:01.776Z",
"dateReserved": "2024-07-16T17:54:02.625Z",
"dateUpdated": "2024-09-09T20:08:01.134Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43935 (GCVE-0-2021-43935)
Vulnerability from nvd – Published: 2021-12-15 18:05 – Updated: 2024-09-16 23:11
VLAI
EPSS
VEX
Title
ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products
Summary
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.
Severity
8.1 (High)
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsma-… | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hillrom | Welch Allyn Q-Stress Cardiac Stress Testing System |
Affected:
6.0.0 , ≤ 6.3.1
(custom)
|
|
| Hillrom | Welch Allyn X-Scribe Cardiac Stress Testing System |
Affected:
5.01 , ≤ 6.3.1
(custom)
|
|
| Hillrom | Welch Allyn Diagnostic Cardiology Suite |
Affected:
2.1.0
|
|
| Hillrom | Welch Allyn Vision Express |
Affected:
6.1.0 , ≤ 6.4.0
(custom)
|
|
| Hillrom | Welch Allyn H-Scribe Holter Analysis System |
Affected:
5.01 , ≤ 6.4.0
(custom)
|
|
| Hillrom | Welch Allyn R-Scribe Resting ECG System |
Affected:
5.01 , ≤ 7.0.0
(custom)
|
|
| Hillrom | Welch Allyn Connex Cardio |
Affected:
1.0.0 , ≤ 1.1.1
(custom)
|
Date Public
2021-12-09 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:10:16.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn Q-Stress Cardiac Stress Testing System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.3.1",
"status": "affected",
"version": "6.0.0",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn X-Scribe Cardiac Stress Testing System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.3.1",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn Diagnostic Cardiology Suite",
"vendor": "Hillrom",
"versions": [
{
"status": "affected",
"version": "2.1.0"
}
]
},
{
"product": "Welch Allyn Vision Express",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.4.0",
"status": "affected",
"version": "6.1.0",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn H-Scribe Holter Analysis System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.4.0",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn R-Scribe Resting ECG System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "7.0.0",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn Connex Cardio",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "1.1.1",
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Hillrom reported this vulnerability to CISA"
}
],
"datePublic": "2021-12-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-15T18:05:16.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Hillrom recommends users upgrade to the latest product versions when updated products are available. Information on how to update these products to their new versions can be found on the Hillrom disclosure page."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products",
"workarounds": [
{
"lang": "en",
"value": "-Disable the SSO feature in the respective Modality Manager Configuration settings. Please refer to the instructions for use (IFU) and/or service manual for instructions on how to disable SSO.\n-Apply proper network and physical security controls.\n-Apply authentication for server access."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-12-09T17:10:00.000Z",
"ID": "CVE-2021-43935",
"STATE": "PUBLIC",
"TITLE": "ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn Q-Stress Cardiac Stress Testing System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.0.0",
"version_value": "6.3.1"
}
]
}
},
{
"product_name": "Welch Allyn X-Scribe Cardiac Stress Testing System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "6.3.1"
}
]
}
},
{
"product_name": "Welch Allyn Diagnostic Cardiology Suite",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "2.1.0",
"version_value": "2.1.0"
}
]
}
},
{
"product_name": "Welch Allyn Vision Express",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.1.0",
"version_value": "6.4.0"
}
]
}
},
{
"product_name": "Welch Allyn H-Scribe Holter Analysis System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "6.4.0"
}
]
}
},
{
"product_name": "Welch Allyn R-Scribe Resting ECG System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "7.0.0"
}
]
}
},
{
"product_name": "Welch Allyn Connex Cardio",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "1.0.0",
"version_value": "1.1.1"
}
]
}
}
]
},
"vendor_name": "Hillrom"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Hillrom reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Hillrom recommends users upgrade to the latest product versions when updated products are available. Information on how to update these products to their new versions can be found on the Hillrom disclosure page."
}
],
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "-Disable the SSO feature in the respective Modality Manager Configuration settings. Please refer to the instructions for use (IFU) and/or service manual for instructions on how to disable SSO.\n-Apply proper network and physical security controls.\n-Apply authentication for server access."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-43935",
"datePublished": "2021-12-15T18:05:16.799Z",
"dateReserved": "2021-11-16T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:11:47.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27410 (GCVE-0-2021-27410)
Vulnerability from nvd – Published: 2021-06-11 16:33 – Updated: 2024-08-03 20:48
VLAI
EPSS
VEX
Summary
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Severity
No CVSS data available.
CWE
- CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Welch Allyn medical device management tools |
Affected:
Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.754Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn medical device management tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "OUT-OF-BOUNDS WRITE CWE-787",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T16:33:21.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27410",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn medical device management tools",
"version": {
"version_data": [
{
"version_value": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS WRITE CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27410",
"datePublished": "2021-06-11T16:33:21.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.754Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27408 (GCVE-0-2021-27408)
Vulnerability from nvd – Published: 2021-06-11 16:31 – Updated: 2024-08-03 20:48
VLAI
EPSS
VEX
Summary
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Welch Allyn medical device management tools |
Affected:
Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn medical device management tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T16:31:58.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27408",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn medical device management tools",
"version": {
"version_data": [
{
"version_value": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27408",
"datePublished": "2021-06-11T16:31:58.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6796 (GCVE-0-2024-6796)
Vulnerability from cvelistv5 – Published: 2024-09-09 19:28 – Updated: 2024-09-09 20:08
VLAI
EPSS
VEX
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-09 19:51 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Baxter | Connex Health Portal |
Affected:
0 , < 8/30/2024
(date)
|
|
| hillrom | connex_health_portal |
Affected:
0 , < 8.30.2024
(custom)
cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "connex_health_portal",
"vendor": "hillrom",
"versions": [
{
"lessThan": "8.30.2024",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6796",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T19:51:44.387310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T20:08:22.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Connex Health Portal",
"vendor": "Baxter",
"versions": [
{
"lessThan": "8/30/2024",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content.\u0026nbsp;"
}
],
"value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T19:28:30.647Z",
"orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"shortName": "Baxter"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\n\n\u003cbr\u003e"
}
],
"value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Vulnerability in Baxter Connex Health Portal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"assignerShortName": "Baxter",
"cveId": "CVE-2024-6796",
"datePublished": "2024-09-09T19:28:30.647Z",
"dateReserved": "2024-07-16T17:54:05.755Z",
"dateUpdated": "2024-09-09T20:08:22.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6795 (GCVE-0-2024-6795)
Vulnerability from cvelistv5 – Published: 2024-09-09 19:24 – Updated: 2024-09-09 20:08
VLAI
EPSS
VEX
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.
An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content
and/or perform administrative operations including shutting down the database.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-09 20:04 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Baxter | Connex Health Portal |
Affected:
0 , < 8/30/2024
(date)
|
|
| hillrom | connex_health_portal |
Affected:
0 , < 8.30.2024
(custom)
cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "connex_health_portal",
"vendor": "hillrom",
"versions": [
{
"lessThan": "8.30.2024",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6795",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T20:04:42.779977Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T20:08:01.134Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Connex Health Portal",
"vendor": "Baxter",
"versions": [
{
"lessThan": "8/30/2024",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u0026nbsp;\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
}
],
"value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u00a0\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
}
],
"impacts": [
{
"capecId": "CAPEC-23",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-23 File Content Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T19:24:01.776Z",
"orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"shortName": "Baxter"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\u003cbr\u003e"
}
],
"value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Vulnerability in Baxter Connex Health Portal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
"assignerShortName": "Baxter",
"cveId": "CVE-2024-6795",
"datePublished": "2024-09-09T19:24:01.776Z",
"dateReserved": "2024-07-16T17:54:02.625Z",
"dateUpdated": "2024-09-09T20:08:01.134Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43935 (GCVE-0-2021-43935)
Vulnerability from cvelistv5 – Published: 2021-12-15 18:05 – Updated: 2024-09-16 23:11
VLAI
EPSS
VEX
Title
ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products
Summary
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.
Severity
8.1 (High)
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsma-… | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hillrom | Welch Allyn Q-Stress Cardiac Stress Testing System |
Affected:
6.0.0 , ≤ 6.3.1
(custom)
|
|
| Hillrom | Welch Allyn X-Scribe Cardiac Stress Testing System |
Affected:
5.01 , ≤ 6.3.1
(custom)
|
|
| Hillrom | Welch Allyn Diagnostic Cardiology Suite |
Affected:
2.1.0
|
|
| Hillrom | Welch Allyn Vision Express |
Affected:
6.1.0 , ≤ 6.4.0
(custom)
|
|
| Hillrom | Welch Allyn H-Scribe Holter Analysis System |
Affected:
5.01 , ≤ 6.4.0
(custom)
|
|
| Hillrom | Welch Allyn R-Scribe Resting ECG System |
Affected:
5.01 , ≤ 7.0.0
(custom)
|
|
| Hillrom | Welch Allyn Connex Cardio |
Affected:
1.0.0 , ≤ 1.1.1
(custom)
|
Date Public
2021-12-09 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:10:16.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn Q-Stress Cardiac Stress Testing System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.3.1",
"status": "affected",
"version": "6.0.0",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn X-Scribe Cardiac Stress Testing System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.3.1",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn Diagnostic Cardiology Suite",
"vendor": "Hillrom",
"versions": [
{
"status": "affected",
"version": "2.1.0"
}
]
},
{
"product": "Welch Allyn Vision Express",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.4.0",
"status": "affected",
"version": "6.1.0",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn H-Scribe Holter Analysis System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "6.4.0",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn R-Scribe Resting ECG System",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "7.0.0",
"status": "affected",
"version": "5.01",
"versionType": "custom"
}
]
},
{
"product": "Welch Allyn Connex Cardio",
"vendor": "Hillrom",
"versions": [
{
"lessThanOrEqual": "1.1.1",
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Hillrom reported this vulnerability to CISA"
}
],
"datePublic": "2021-12-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-15T18:05:16.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Hillrom recommends users upgrade to the latest product versions when updated products are available. Information on how to update these products to their new versions can be found on the Hillrom disclosure page."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products",
"workarounds": [
{
"lang": "en",
"value": "-Disable the SSO feature in the respective Modality Manager Configuration settings. Please refer to the instructions for use (IFU) and/or service manual for instructions on how to disable SSO.\n-Apply proper network and physical security controls.\n-Apply authentication for server access."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-12-09T17:10:00.000Z",
"ID": "CVE-2021-43935",
"STATE": "PUBLIC",
"TITLE": "ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn Q-Stress Cardiac Stress Testing System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.0.0",
"version_value": "6.3.1"
}
]
}
},
{
"product_name": "Welch Allyn X-Scribe Cardiac Stress Testing System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "6.3.1"
}
]
}
},
{
"product_name": "Welch Allyn Diagnostic Cardiology Suite",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "2.1.0",
"version_value": "2.1.0"
}
]
}
},
{
"product_name": "Welch Allyn Vision Express",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.1.0",
"version_value": "6.4.0"
}
]
}
},
{
"product_name": "Welch Allyn H-Scribe Holter Analysis System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "6.4.0"
}
]
}
},
{
"product_name": "Welch Allyn R-Scribe Resting ECG System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "5.01",
"version_value": "7.0.0"
}
]
}
},
{
"product_name": "Welch Allyn Connex Cardio",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "1.0.0",
"version_value": "1.1.1"
}
]
}
}
]
},
"vendor_name": "Hillrom"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Hillrom reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Hillrom recommends users upgrade to the latest product versions when updated products are available. Information on how to update these products to their new versions can be found on the Hillrom disclosure page."
}
],
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "-Disable the SSO feature in the respective Modality Manager Configuration settings. Please refer to the instructions for use (IFU) and/or service manual for instructions on how to disable SSO.\n-Apply proper network and physical security controls.\n-Apply authentication for server access."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-43935",
"datePublished": "2021-12-15T18:05:16.799Z",
"dateReserved": "2021-11-16T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:11:47.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27410 (GCVE-0-2021-27410)
Vulnerability from cvelistv5 – Published: 2021-06-11 16:33 – Updated: 2024-08-03 20:48
VLAI
EPSS
VEX
Summary
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Severity
No CVSS data available.
CWE
- CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Welch Allyn medical device management tools |
Affected:
Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.754Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn medical device management tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "OUT-OF-BOUNDS WRITE CWE-787",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T16:33:21.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27410",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn medical device management tools",
"version": {
"version_data": [
{
"version_value": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS WRITE CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27410",
"datePublished": "2021-06-11T16:33:21.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.754Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27408 (GCVE-0-2021-27408)
Vulnerability from cvelistv5 – Published: 2021-06-11 16:31 – Updated: 2024-08-03 20:48
VLAI
EPSS
VEX
Summary
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Welch Allyn medical device management tools |
Affected:
Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn medical device management tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T16:31:58.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27408",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn medical device management tools",
"version": {
"version_data": [
{
"version_value": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27408",
"datePublished": "2021-06-11T16:31:58.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}