Search

Find a vulnerability

Search criteria

    66 vulnerabilities by belkin

    CVE-2026-4167 (GCVE-0-2026-4167)

    Vulnerability from nvd – Published: 2026-03-15 05:32 – Updated: 2026-03-17 13:48
    VLAI
    Title
    Belkin F9K1122 formReboot stack-based overflow
    Summary
    A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-17 13:48 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Belkin F9K1122 Affected: 1.00.33
        cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-4167",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-17T13:48:03.295126Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-17T13:48:43.966Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F9K1122",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.00.33"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHust2 (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-15T05:32:10.557Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-351074 | Belkin F9K1122 formReboot stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.351074"
            },
            {
              "name": "VDB-351074 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.351074"
            },
            {
              "name": "Submit #769727 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.769727"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md#proof-of-concept-poc"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-14T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-14T13:37:42.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin F9K1122 formReboot stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-4167",
        "datePublished": "2026-03-15T05:32:10.557Z",
        "dateReserved": "2026-03-14T12:32:38.218Z",
        "dateUpdated": "2026-03-17T13:48:43.966Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-9379 (GCVE-0-2025-9379)

    Vulnerability from nvd – Published: 2025-08-24 06:32 – Updated: 2025-08-25 20:22
    VLAI
    Title
    Belkin AX1800 Firmware Update data authenticity
    Summary
    A vulnerability was determined in Belkin AX1800 1.1.00.016. Affected by this vulnerability is an unknown functionality of the component Firmware Update Handler. This manipulation causes insufficient verification of data authenticity. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-25 20:22 UTC
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    References
    Impacted products
    Vendor Product Version
    Belkin AX1800 Affected: 1.1.00.016
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9379",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-25T20:22:20.066387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-25T20:22:36.309Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Firmware Update Handler"
              ],
              "product": "AX1800",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.00.016"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "IOT_Res (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Belkin AX1800 1.1.00.016. Affected by this vulnerability is an unknown functionality of the component Firmware Update Handler. This manipulation causes insufficient verification of data authenticity. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Belkin AX1800 1.1.00.016 gefunden. Dies betrifft einen unbekannten Teil der Komponente Firmware Update Handler. Durch Beeinflussen mit unbekannten Daten kann eine insufficient verification of data authenticity-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-24T06:32:06.208Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-321212 | Belkin AX1800 Firmware Update data authenticity",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.321212"
            },
            {
              "name": "VDB-321212 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.321212"
            },
            {
              "name": "Submit #628641 | Belkin AX1800 WiFi 6 Router V1.1.00.016 CWE-20 Improper Input Validation",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.628641"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://github.com/IOTRes/IOT_Firmware_Update/blob/main/Belkin/AX1800.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-23T17:00:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin AX1800 Firmware Update data authenticity"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9379",
        "datePublished": "2025-08-24T06:32:06.208Z",
        "dateReserved": "2025-08-23T14:55:35.639Z",
        "dateUpdated": "2025-08-25T20:22:36.309Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-8730 (GCVE-0-2025-8730)

    Vulnerability from nvd – Published: 2025-08-08 14:32 – Updated: 2025-08-08 14:51
    VLAI
    Title
    Belkin F9K1009/F9K1010 Web Interface hard-coded credentials
    Summary
    A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-08 14:51 UTC
    CWE
    • CWE-798 - Hard-coded Credentials
    • CWE-259 - Use of Hard-coded Password
    Impacted products
    Vendor Product Version
    Belkin F9K1009 Affected: 2.00.04
    Affected: 2.00.09
    Create a notification for this product.
    Belkin F9K1010 Affected: 2.00.04
    Affected: 2.00.09
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-8730",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-08T14:51:44.482035Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-08T14:51:56.546Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Web Interface"
              ],
              "product": "F9K1009",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.00.04"
                },
                {
                  "status": "affected",
                  "version": "2.00.09"
                }
              ]
            },
            {
              "modules": [
                "Web Interface"
              ],
              "product": "F9K1010",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.00.04"
                },
                {
                  "status": "affected",
                  "version": "2.00.09"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "nich0las (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Komponente Web Interface. Mittels Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-08T14:32:05.215Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-319226 | Belkin F9K1009/F9K1010 Web Interface hard-coded credentials",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.319226"
            },
            {
              "name": "VDB-319226 | CTI Indicators (IOB, IOC, TTP)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.319226"
            },
            {
              "name": "Submit #621747 | Belkin F9K1009 F9K1009_WW_2.00.09 Use of Hard-coded Password",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621747"
            },
            {
              "name": "Submit #621748 | belkin F9K1010 F9K1010_WW_2.00.04 Use of Hard-coded Password (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621748"
            },
            {
              "name": "Submit #621760 | belkin F9K1010 F9K1010_WW_2.00.04 Use of Weak Credentials (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621760"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Nicholas-wei/bug-discovery/blob/main/belkin/F9K1009_WW_2.00.09/belkin%20F9K1009_WW_2.00.09_hardcoded_credential.pdf"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Nicholas-wei/bug-discovery/blob/main/belkin/F9K1010_WW_2.00.04/belkin_F9K1010_WW_2.00.04_hardcoded_credential.pdf"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-08T09:45:09.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin F9K1009/F9K1010 Web Interface hard-coded credentials"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-8730",
        "datePublished": "2025-08-08T14:32:05.215Z",
        "dateReserved": "2025-08-08T07:40:01.538Z",
        "dateUpdated": "2025-08-08T14:51:56.546Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-1635 (GCVE-0-2014-1635)

    Vulnerability from nvd – Published: 2014-11-12 16:00 – Updated: 2024-08-06 09:50
    VLAI
    Summary
    Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2014-11-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T09:50:09.812Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
              },
              {
                "name": "35184",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/35184"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.belkin.com/us/support-article?articleNum=4831"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
              },
              {
                "name": "114345",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/show/osvdb/114345"
              },
              {
                "name": "1031210",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1031210"
              },
              {
                "name": "70977",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/70977"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-11-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-05-18T12:57:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
            },
            {
              "name": "35184",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/35184"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.belkin.com/us/support-article?articleNum=4831"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
            },
            {
              "name": "114345",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/show/osvdb/114345"
            },
            {
              "name": "1031210",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1031210"
            },
            {
              "name": "70977",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/70977"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-1635",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/",
                  "refsource": "MISC",
                  "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
                },
                {
                  "name": "35184",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/35184"
                },
                {
                  "name": "http://www.belkin.com/us/support-article?articleNum=4831",
                  "refsource": "CONFIRM",
                  "url": "http://www.belkin.com/us/support-article?articleNum=4831"
                },
                {
                  "name": "https://labs.integrity.pt/advisories/cve-2014-1635/",
                  "refsource": "MISC",
                  "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
                },
                {
                  "name": "114345",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/show/osvdb/114345"
                },
                {
                  "name": "1031210",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1031210"
                },
                {
                  "name": "70977",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/70977"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-1635",
        "datePublished": "2014-11-12T16:00:00.000Z",
        "dateReserved": "2014-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T09:50:09.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3092 (GCVE-0-2013-3092)

    Vulnerability from nvd – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3092",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3092",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3089 (GCVE-0-2013-3089)

    Vulnerability from nvd – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.707Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3089",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3089",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.707Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3086 (GCVE-0-2013-3086)

    Vulnerability from nvd – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.590Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3086",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3086",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.590Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3083 (GCVE-0-2013-3083)

    Vulnerability from nvd – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.754Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3083",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3083",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.754Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-2962 (GCVE-0-2014-2962)

    Vulnerability from nvd – Published: 2014-06-19 10:00 – Updated: 2024-08-06 10:28
    VLAI
    Summary
    Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://www.exploit-db.com/exploits/38488/ exploitx_refsource_EXPLOIT-DB
    http://www.kb.cert.org/vuls/id/774788 third-party-advisoryx_refsource_CERT-VN
    http://www.belkin.com/us/support-article?articleN… x_refsource_CONFIRM
    Date Public
    2014-06-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T10:28:46.378Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "38488",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/38488/"
              },
              {
                "name": "VU#774788",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/774788"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.belkin.com/us/support-article?articleNum=109400"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-06-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-12-22T18:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "38488",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/38488/"
            },
            {
              "name": "VU#774788",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/774788"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.belkin.com/us/support-article?articleNum=109400"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2014-2962",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "38488",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/38488/"
                },
                {
                  "name": "VU#774788",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/774788"
                },
                {
                  "name": "http://www.belkin.com/us/support-article?articleNum=109400",
                  "refsource": "CONFIRM",
                  "url": "http://www.belkin.com/us/support-article?articleNum=109400"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2014-2962",
        "datePublished": "2014-06-19T10:00:00.000Z",
        "dateReserved": "2014-04-21T00:00:00.000Z",
        "dateUpdated": "2024-08-06T10:28:46.378Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6952 (GCVE-0-2013-6952)

    Vulnerability from nvd – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.562Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6952",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6952",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.562Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6951 (GCVE-0-2013-6951)

    Vulnerability from nvd – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.327Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-22T21:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6951",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6951",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6950 (GCVE-0-2013-6950)

    Vulnerability from nvd – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6950",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6950",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6949 (GCVE-0-2013-6949)

    Vulnerability from nvd – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.393Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6949",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6949",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6948 (GCVE-0-2013-6948)

    Vulnerability from nvd – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.456Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6948",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6948",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.456Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3090 (GCVE-0-2013-3090)

    Vulnerability from nvd – Published: 2014-01-30 15:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Multiple cross-site scripting (XSS) vulnerabilities in Belkin N300 router allow remote attackers to inject arbitrary web script or HTML via the Guest Access PSK field to wireless_guest2_print.stm or other unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2013-04-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.709Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "name": "belkin-n300-cve20133090-unspecified-xss(83837)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83837"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple cross-site scripting (XSS) vulnerabilities in Belkin N300 router allow remote attackers to inject arbitrary web script or HTML via the Guest Access PSK field to wireless_guest2_print.stm or other unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "name": "belkin-n300-cve20133090-unspecified-xss(83837)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83837"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3090",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple cross-site scripting (XSS) vulnerabilities in Belkin N300 router allow remote attackers to inject arbitrary web script or HTML via the Guest Access PSK field to wireless_guest2_print.stm or other unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "belkin-n300-cve20133090-unspecified-xss(83837)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83837"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3090",
        "datePublished": "2014-01-30T15:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.709Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3087 (GCVE-0-2013-3087)

    Vulnerability from nvd – Published: 2014-01-30 15:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Multiple cross-site scripting (XSS) vulnerabilities in Belkin N900 router allow remote attackers to inject arbitrary web script or HTML via the (1) ssid2 parameter to wl_channel.html or (2) guest_psk parameter to wl_guest.html.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2013-04-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:10.009Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              },
              {
                "name": "belkin-n900-cve20133087-xss(83831)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83831"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple cross-site scripting (XSS) vulnerabilities in Belkin N900 router allow remote attackers to inject arbitrary web script or HTML via the (1) ssid2 parameter to wl_channel.html or (2) guest_psk parameter to wl_guest.html."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            },
            {
              "name": "belkin-n900-cve20133087-xss(83831)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83831"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3087",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple cross-site scripting (XSS) vulnerabilities in Belkin N900 router allow remote attackers to inject arbitrary web script or HTML via the (1) ssid2 parameter to wl_channel.html or (2) guest_psk parameter to wl_guest.html."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/content/case-studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                },
                {
                  "name": "belkin-n900-cve20133087-xss(83831)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83831"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3087",
        "datePublished": "2014-01-30T15:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:10.009Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-4167 (GCVE-0-2026-4167)

    Vulnerability from cvelistv5 – Published: 2026-03-15 05:32 – Updated: 2026-03-17 13:48
    VLAI
    Title
    Belkin F9K1122 formReboot stack-based overflow
    Summary
    A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-17 13:48 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Belkin F9K1122 Affected: 1.00.33
        cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-4167",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-17T13:48:03.295126Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-17T13:48:43.966Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F9K1122",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.00.33"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHust2 (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-15T05:32:10.557Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-351074 | Belkin F9K1122 formReboot stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.351074"
            },
            {
              "name": "VDB-351074 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.351074"
            },
            {
              "name": "Submit #769727 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.769727"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md#proof-of-concept-poc"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-14T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-14T13:37:42.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin F9K1122 formReboot stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-4167",
        "datePublished": "2026-03-15T05:32:10.557Z",
        "dateReserved": "2026-03-14T12:32:38.218Z",
        "dateUpdated": "2026-03-17T13:48:43.966Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-9379 (GCVE-0-2025-9379)

    Vulnerability from cvelistv5 – Published: 2025-08-24 06:32 – Updated: 2025-08-25 20:22
    VLAI
    Title
    Belkin AX1800 Firmware Update data authenticity
    Summary
    A vulnerability was determined in Belkin AX1800 1.1.00.016. Affected by this vulnerability is an unknown functionality of the component Firmware Update Handler. This manipulation causes insufficient verification of data authenticity. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-25 20:22 UTC
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    References
    Impacted products
    Vendor Product Version
    Belkin AX1800 Affected: 1.1.00.016
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9379",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-25T20:22:20.066387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-25T20:22:36.309Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Firmware Update Handler"
              ],
              "product": "AX1800",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.00.016"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "IOT_Res (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Belkin AX1800 1.1.00.016. Affected by this vulnerability is an unknown functionality of the component Firmware Update Handler. This manipulation causes insufficient verification of data authenticity. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Belkin AX1800 1.1.00.016 gefunden. Dies betrifft einen unbekannten Teil der Komponente Firmware Update Handler. Durch Beeinflussen mit unbekannten Daten kann eine insufficient verification of data authenticity-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-24T06:32:06.208Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-321212 | Belkin AX1800 Firmware Update data authenticity",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.321212"
            },
            {
              "name": "VDB-321212 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.321212"
            },
            {
              "name": "Submit #628641 | Belkin AX1800 WiFi 6 Router V1.1.00.016 CWE-20 Improper Input Validation",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.628641"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://github.com/IOTRes/IOT_Firmware_Update/blob/main/Belkin/AX1800.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-23T17:00:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin AX1800 Firmware Update data authenticity"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9379",
        "datePublished": "2025-08-24T06:32:06.208Z",
        "dateReserved": "2025-08-23T14:55:35.639Z",
        "dateUpdated": "2025-08-25T20:22:36.309Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-8730 (GCVE-0-2025-8730)

    Vulnerability from cvelistv5 – Published: 2025-08-08 14:32 – Updated: 2025-08-08 14:51
    VLAI
    Title
    Belkin F9K1009/F9K1010 Web Interface hard-coded credentials
    Summary
    A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-08 14:51 UTC
    CWE
    • CWE-798 - Hard-coded Credentials
    • CWE-259 - Use of Hard-coded Password
    Impacted products
    Vendor Product Version
    Belkin F9K1009 Affected: 2.00.04
    Affected: 2.00.09
    Create a notification for this product.
    Belkin F9K1010 Affected: 2.00.04
    Affected: 2.00.09
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-8730",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-08T14:51:44.482035Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-08T14:51:56.546Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Web Interface"
              ],
              "product": "F9K1009",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.00.04"
                },
                {
                  "status": "affected",
                  "version": "2.00.09"
                }
              ]
            },
            {
              "modules": [
                "Web Interface"
              ],
              "product": "F9K1010",
              "vendor": "Belkin",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.00.04"
                },
                {
                  "status": "affected",
                  "version": "2.00.09"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "nich0las (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Komponente Web Interface. Mittels Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-08T14:32:05.215Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-319226 | Belkin F9K1009/F9K1010 Web Interface hard-coded credentials",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.319226"
            },
            {
              "name": "VDB-319226 | CTI Indicators (IOB, IOC, TTP)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.319226"
            },
            {
              "name": "Submit #621747 | Belkin F9K1009 F9K1009_WW_2.00.09 Use of Hard-coded Password",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621747"
            },
            {
              "name": "Submit #621748 | belkin F9K1010 F9K1010_WW_2.00.04 Use of Hard-coded Password (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621748"
            },
            {
              "name": "Submit #621760 | belkin F9K1010 F9K1010_WW_2.00.04 Use of Weak Credentials (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.621760"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Nicholas-wei/bug-discovery/blob/main/belkin/F9K1009_WW_2.00.09/belkin%20F9K1009_WW_2.00.09_hardcoded_credential.pdf"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Nicholas-wei/bug-discovery/blob/main/belkin/F9K1010_WW_2.00.04/belkin_F9K1010_WW_2.00.04_hardcoded_credential.pdf"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-08T09:45:09.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Belkin F9K1009/F9K1010 Web Interface hard-coded credentials"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-8730",
        "datePublished": "2025-08-08T14:32:05.215Z",
        "dateReserved": "2025-08-08T07:40:01.538Z",
        "dateUpdated": "2025-08-08T14:51:56.546Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-1635 (GCVE-0-2014-1635)

    Vulnerability from cvelistv5 – Published: 2014-11-12 16:00 – Updated: 2024-08-06 09:50
    VLAI
    Summary
    Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2014-11-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T09:50:09.812Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
              },
              {
                "name": "35184",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/35184"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.belkin.com/us/support-article?articleNum=4831"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
              },
              {
                "name": "114345",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/show/osvdb/114345"
              },
              {
                "name": "1031210",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1031210"
              },
              {
                "name": "70977",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/70977"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-11-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-05-18T12:57:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
            },
            {
              "name": "35184",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/35184"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.belkin.com/us/support-article?articleNum=4831"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
            },
            {
              "name": "114345",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/show/osvdb/114345"
            },
            {
              "name": "1031210",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1031210"
            },
            {
              "name": "70977",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/70977"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-1635",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow in login.cgi in MiniHttpd in Belkin N750 Router with firmware before F9K1103_WW_1.10.17m allows remote attackers to execute arbitrary code via a long string in the jump parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/",
                  "refsource": "MISC",
                  "url": "https://labs.integrity.pt/articles/from-0-day-to-exploit-buffer-overflow-in-belkin-n750-cve-2014-1635/"
                },
                {
                  "name": "35184",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/35184"
                },
                {
                  "name": "http://www.belkin.com/us/support-article?articleNum=4831",
                  "refsource": "CONFIRM",
                  "url": "http://www.belkin.com/us/support-article?articleNum=4831"
                },
                {
                  "name": "https://labs.integrity.pt/advisories/cve-2014-1635/",
                  "refsource": "MISC",
                  "url": "https://labs.integrity.pt/advisories/cve-2014-1635/"
                },
                {
                  "name": "114345",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/show/osvdb/114345"
                },
                {
                  "name": "1031210",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1031210"
                },
                {
                  "name": "70977",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/70977"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-1635",
        "datePublished": "2014-11-12T16:00:00.000Z",
        "dateReserved": "2014-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T09:50:09.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3089 (GCVE-0-2013-3089)

    Vulnerability from cvelistv5 – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.707Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3089",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in apply.cgi in Belkin N300 (F7D7301v1) router allows remote attackers to hijack the authentication of administrators for requests that modify configuration."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3089",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.707Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3092 (GCVE-0-2013-3092)

    Vulnerability from cvelistv5 – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3092",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3092",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3086 (GCVE-0-2013-3086)

    Vulnerability from cvelistv5 – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.590Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3086",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in util_system.html in Belkin N900 router allows remote attackers to hijack the authentication of administrators for requests that change configuration settings including passwords and remote management ports."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                },
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/belkin_n900.php"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3086",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.590Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3083 (GCVE-0-2013-3083)

    Vulnerability from cvelistv5 – Published: 2014-09-29 22:00 – Updated: 2024-08-06 16:00
    VLAI
    Summary
    Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2013-04-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.754Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-09-29T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-3083",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/system_setting.exe in Belkin F5D8236-4 v2 allows remote attackers to hijack the authentication of administrators for requests that open the remote management interface on arbitrary ports via the remote_mgmt_enabled and remote_mgmt_port parameters."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf",
                  "refsource": "MISC",
                  "url": "http://securityevaluators.com/knowledge/case_studies/routers/Vulnerability_Catalog.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-3083",
        "datePublished": "2014-09-29T22:00:00.000Z",
        "dateReserved": "2013-04-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T16:00:09.754Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-2962 (GCVE-0-2014-2962)

    Vulnerability from cvelistv5 – Published: 2014-06-19 10:00 – Updated: 2024-08-06 10:28
    VLAI
    Summary
    Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://www.exploit-db.com/exploits/38488/ exploitx_refsource_EXPLOIT-DB
    http://www.kb.cert.org/vuls/id/774788 third-party-advisoryx_refsource_CERT-VN
    http://www.belkin.com/us/support-article?articleN… x_refsource_CONFIRM
    Date Public
    2014-06-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T10:28:46.378Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "38488",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/38488/"
              },
              {
                "name": "VU#774788",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/774788"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.belkin.com/us/support-article?articleNum=109400"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-06-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-12-22T18:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "38488",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/38488/"
            },
            {
              "name": "VU#774788",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/774788"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.belkin.com/us/support-article?articleNum=109400"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2014-2962",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Absolute path traversal vulnerability in the webproc cgi module on the Belkin N150 F9K1009 v1 router with firmware before 1.00.08 allows remote attackers to read arbitrary files via a full pathname in the getpage parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "38488",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/38488/"
                },
                {
                  "name": "VU#774788",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/774788"
                },
                {
                  "name": "http://www.belkin.com/us/support-article?articleNum=109400",
                  "refsource": "CONFIRM",
                  "url": "http://www.belkin.com/us/support-article?articleNum=109400"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2014-2962",
        "datePublished": "2014-06-19T10:00:00.000Z",
        "dateReserved": "2014-04-21T00:00:00.000Z",
        "dateUpdated": "2024-08-06T10:28:46.378Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6948 (GCVE-0-2013-6948)

    Vulnerability from cvelistv5 – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.456Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6948",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The peerAddresses API in the Belkin WeMo Home Automation firmware before 3949 allows remote attackers to read arbitrary files via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6948",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.456Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6951 (GCVE-0-2013-6951)

    Vulnerability from cvelistv5 – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.327Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-22T21:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6951",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not maintain a set of Certification Authority public keys, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary X.509 certificate."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6951",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6950 (GCVE-0-2013-6950)

    Vulnerability from cvelistv5 – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6950",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not use SSL for the distribution feed, which allows man-in-the-middle attackers to install arbitrary firmware by spoofing a distribution server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6950",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6949 (GCVE-0-2013-6949)

    Vulnerability from cvelistv5 – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.393Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6949",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 does not properly use the STUN and TURN protocols, which allows remote attackers to hijack connections and possibly have unspecified other impact by leveraging access to a single WeMo device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6949",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-6952 (GCVE-0-2013-6952)

    Vulnerability from cvelistv5 – Published: 2014-02-22 21:00 – Updated: 2024-08-06 17:53
    VLAI
    Summary
    The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.ioactive.com/pdfs/IOActive_Belkin-advi… x_refsource_MISC
    http://www.kb.cert.org/vuls/id/656302 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2014-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T17:53:45.562Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
              },
              {
                "name": "VU#656302",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/656302"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2014-02-24T05:57:03.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
            },
            {
              "name": "VU#656302",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/656302"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-6952",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Belkin WeMo Home Automation firmware before 3949 has a hardcoded GPG key, which makes it easier for remote attackers to spoof firmware updates and execute arbitrary code via crafted signed data."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf",
                  "refsource": "MISC",
                  "url": "http://www.ioactive.com/pdfs/IOActive_Belkin-advisory-lite.pdf"
                },
                {
                  "name": "VU#656302",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/656302"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-6952",
        "datePublished": "2014-02-22T21:00:00.000Z",
        "dateReserved": "2013-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T17:53:45.562Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }