    CVE-2017-14019 (GCVE-0-2017-14019)

    Vulnerability from nvd – Published: 2017-10-19 23:00 – Updated: 2024-08-05 19:13
    VLAI
    Summary
    An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges.
    Severity
    No CVSS data available.
    CWE
    References
    Impacted products
    Vendor Product Version
    n/a Progea Movicon SCADA/HMI Affected: Progea Movicon SCADA/HMI
    Date Public
    2017-10-19 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:13:41.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "101483",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101483"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Progea Movicon SCADA/HMI",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Progea Movicon SCADA/HMI"
                }
              ]
            }
          ],
          "datePublic": "2017-10-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "CWE-428",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-20T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "101483",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101483"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-14019",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Progea Movicon SCADA/HMI",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Progea Movicon SCADA/HMI"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-428"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "101483",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101483"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-14019",
        "datePublished": "2017-10-19T23:00:00.000Z",
        "dateReserved": "2017-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:13:41.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-14017 (GCVE-0-2017-14017)

    Vulnerability from nvd – Published: 2017-10-19 23:00 – Updated: 2024-08-05 19:13
    VLAI
    Summary
    An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file.
    Severity
    No CVSS data available.
    CWE
    References
    Impacted products
    Vendor Product Version
    n/a Progea Movicon SCADA/HMI Affected: Progea Movicon SCADA/HMI
    Date Public
    2017-10-19 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:13:41.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "101483",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101483"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Progea Movicon SCADA/HMI",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Progea Movicon SCADA/HMI"
                }
              ]
            }
          ],
          "datePublic": "2017-10-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-20T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "101483",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101483"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-14017",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Progea Movicon SCADA/HMI",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Progea Movicon SCADA/HMI"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-427"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "101483",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101483"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-14017",
        "datePublished": "2017-10-19T23:00:00.000Z",
        "dateReserved": "2017-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:13:41.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-0778 (GCVE-0-2014-0778)

    Vulnerability from nvd – Published: 2014-04-19 19:00 – Updated: 2025-09-24 21:24
    VLAI
    Title
    Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor
    Summary
    TCPUploader module listens on Port 10651/TCP for incoming connections. Exploitation of this vulnerability could allow a remote unauthenticated user access to release OS version information. While this is a minor vulnerability, it represents a method for further network reconnaissance.
    Severity
    No CVSS data available.
    CWE
    Impacted products
    Vendor Product Version
    Progea Movicon Affected: 11.4 , < Build 1150 (custom)
    Unaffected: 11.4.1150
    Create a notification for this product.
    Date Public
    2014-04-15 06:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T09:27:19.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Movicon",
              "vendor": "Progea",
              "versions": [
                {
                  "lessThan": "Build 1150",
                  "status": "affected",
                  "version": "11.4",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "11.4.1150"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Celil \u00dcn\u00fcver of SignalSEC Ltd."
            }
          ],
          "datePublic": "2014-04-15T06:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "TCPUploader module listens on Port 10651/TCP for incoming connections. \nExploitation of this vulnerability could allow a remote unauthenticated \nuser access to release OS version information. While this is a minor \nvulnerability, it represents a method for further network \nreconnaissance."
                }
              ],
              "value": "TCPUploader module listens on Port 10651/TCP for incoming connections. \nExploitation of this vulnerability could allow a remote unauthenticated \nuser access to release OS version information. While this is a minor \nvulnerability, it represents a method for further network \nreconnaissance."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-24T21:24:10.830Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-105-01"
            },
            {
              "url": "http://www.progea.com/it-it/downloads/software.aspx"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eProgea has updated and fixed the vulnerability in Movicon Version \n11.4.1150. This is available as a download from the Progea Technical \nSupport site:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.progea.com/it-it/downloads/software.aspx\"\u003ehttp://www.progea.com/it-it/downloads/software.aspx\u003c/a\u003e\u0026nbsp;.\u003c/p\u003e\n\u003cp\u003eUsers will be required to register on the Progea web site to download this new version.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Progea has updated and fixed the vulnerability in Movicon Version \n11.4.1150. This is available as a download from the Progea Technical \nSupport site:\u00a0 http://www.progea.com/it-it/downloads/software.aspx \u00a0.\n\n\nUsers will be required to register on the Progea web site to download this new version."
            }
          ],
          "source": {
            "advisory": "ICSA-14-105-01",
            "discovery": "EXTERNAL"
          },
          "title": "Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-0778",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TCPUploader module in Progea Movicon 11.4 before 11.4.1150 allows remote attackers to obtain potentially sensitive version information via network traffic to TCP port 10651."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-0778",
        "datePublished": "2014-04-19T19:00:00.000Z",
        "dateReserved": "2014-01-02T00:00:00.000Z",
        "dateUpdated": "2025-09-24T21:24:10.830Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-1804 (GCVE-0-2012-1804)

    Vulnerability from nvd – Published: 2012-05-14 20:00 – Updated: 2024-08-06 19:08
    VLAI
    Summary
    The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://secunia.com/advisories/49092 third-party-advisoryx_refsource_SECUNIA
    http://osvdb.org/81814 vdb-entryx_refsource_OSVDB
    http://www.securityfocus.com/bid/53484 vdb-entryx_refsource_BID
    Date Public
    2012-05-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T19:08:38.508Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
              },
              {
                "name": "49092",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/49092"
              },
              {
                "name": "81814",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/81814"
              },
              {
                "name": "53484",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/53484"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2012-05-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-05-30T09:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
            },
            {
              "name": "49092",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/49092"
            },
            {
              "name": "81814",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/81814"
            },
            {
              "name": "53484",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/53484"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-1804",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
                },
                {
                  "name": "49092",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/49092"
                },
                {
                  "name": "81814",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/81814"
                },
                {
                  "name": "53484",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/53484"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-1804",
        "datePublished": "2012-05-14T20:00:00.000Z",
        "dateReserved": "2012-03-21T00:00:00.000Z",
        "dateUpdated": "2024-08-06T19:08:38.508Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3499 (GCVE-0-2011-3499)

    Vulnerability from nvd – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.866Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
              },
              {
                "name": "movicon-eidp-dos(69789)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
            },
            {
              "name": "movicon-eidp-dos(69789)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3499",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_3-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
                },
                {
                  "name": "movicon-eidp-dos(69789)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3499",
        "datePublished": "2011-09-16T17:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.866Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3498 (GCVE-0-2011-3498)

    Vulnerability from nvd – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.482Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "movicon-packets-bo(69788)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "movicon-packets-bo(69788)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3498",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "movicon-packets-bo(69788)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
                },
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3498",
        "datePublished": "2011-09-16T17:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3491 (GCVE-0-2011-3491)

    Vulnerability from nvd – Published: 2011-09-16 14:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              },
              {
                "name": "movicon-contentlength-bo(69787)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
              },
              {
                "name": "75494",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/75494"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            },
            {
              "name": "movicon-contentlength-bo(69787)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
            },
            {
              "name": "75494",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/75494"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3491",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                },
                {
                  "name": "movicon-contentlength-bo(69787)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
                },
                {
                  "name": "75494",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/75494"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3491",
        "datePublished": "2011-09-16T14:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.655Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-2963 (GCVE-0-2011-2963)

    Vulnerability from nvd – Published: 2011-07-29 19:00 – Updated: 2024-09-16 23:01
    VLAI
    Summary
    TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:15:32.035Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "46907",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/46907"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
              },
              {
                "name": "72888",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/72888"
              },
              {
                "name": "17034",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/17034"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2011-07-29T19:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "46907",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/46907"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
            },
            {
              "name": "72888",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/72888"
            },
            {
              "name": "17034",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/17034"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-2963",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "46907",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/46907"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
                },
                {
                  "name": "72888",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/72888"
                },
                {
                  "name": "17034",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/17034"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-2963",
        "datePublished": "2011-07-29T19:00:00.000Z",
        "dateReserved": "2011-07-29T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:01:24.729Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-14019 (GCVE-0-2017-14019)

    Vulnerability from cvelistv5 – Published: 2017-10-19 23:00 – Updated: 2024-08-05 19:13
    VLAI
    Summary
    An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges.
    Severity
    No CVSS data available.
    CWE
    References
    Impacted products
    Vendor Product Version
    n/a Progea Movicon SCADA/HMI Affected: Progea Movicon SCADA/HMI
    Date Public
    2017-10-19 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:13:41.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "101483",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101483"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Progea Movicon SCADA/HMI",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Progea Movicon SCADA/HMI"
                }
              ]
            }
          ],
          "datePublic": "2017-10-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "CWE-428",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-20T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "101483",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101483"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-14019",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Progea Movicon SCADA/HMI",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Progea Movicon SCADA/HMI"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-428"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "101483",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101483"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-14019",
        "datePublished": "2017-10-19T23:00:00.000Z",
        "dateReserved": "2017-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:13:41.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-14017 (GCVE-0-2017-14017)

    Vulnerability from cvelistv5 – Published: 2017-10-19 23:00 – Updated: 2024-08-05 19:13
    VLAI
    Summary
    An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file.
    Severity
    No CVSS data available.
    CWE
    References
    Impacted products
    Vendor Product Version
    n/a Progea Movicon SCADA/HMI Affected: Progea Movicon SCADA/HMI
    Date Public
    2017-10-19 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:13:41.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "101483",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101483"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Progea Movicon SCADA/HMI",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Progea Movicon SCADA/HMI"
                }
              ]
            }
          ],
          "datePublic": "2017-10-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-20T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "101483",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101483"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-14017",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Progea Movicon SCADA/HMI",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Progea Movicon SCADA/HMI"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-427"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "101483",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101483"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-14017",
        "datePublished": "2017-10-19T23:00:00.000Z",
        "dateReserved": "2017-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:13:41.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-0778 (GCVE-0-2014-0778)

    Vulnerability from cvelistv5 – Published: 2014-04-19 19:00 – Updated: 2025-09-24 21:24
    VLAI
    Title
    Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor
    Summary
    TCPUploader module listens on Port 10651/TCP for incoming connections. Exploitation of this vulnerability could allow a remote unauthenticated user access to release OS version information. While this is a minor vulnerability, it represents a method for further network reconnaissance.
    Severity
    No CVSS data available.
    CWE
    Impacted products
    Vendor Product Version
    Progea Movicon Affected: 11.4 , < Build 1150 (custom)
    Unaffected: 11.4.1150
    Create a notification for this product.
    Date Public
    2014-04-15 06:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T09:27:19.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Movicon",
              "vendor": "Progea",
              "versions": [
                {
                  "lessThan": "Build 1150",
                  "status": "affected",
                  "version": "11.4",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "11.4.1150"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Celil \u00dcn\u00fcver of SignalSEC Ltd."
            }
          ],
          "datePublic": "2014-04-15T06:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "TCPUploader module listens on Port 10651/TCP for incoming connections. \nExploitation of this vulnerability could allow a remote unauthenticated \nuser access to release OS version information. While this is a minor \nvulnerability, it represents a method for further network \nreconnaissance."
                }
              ],
              "value": "TCPUploader module listens on Port 10651/TCP for incoming connections. \nExploitation of this vulnerability could allow a remote unauthenticated \nuser access to release OS version information. While this is a minor \nvulnerability, it represents a method for further network \nreconnaissance."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-24T21:24:10.830Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-105-01"
            },
            {
              "url": "http://www.progea.com/it-it/downloads/software.aspx"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eProgea has updated and fixed the vulnerability in Movicon Version \n11.4.1150. This is available as a download from the Progea Technical \nSupport site:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.progea.com/it-it/downloads/software.aspx\"\u003ehttp://www.progea.com/it-it/downloads/software.aspx\u003c/a\u003e\u0026nbsp;.\u003c/p\u003e\n\u003cp\u003eUsers will be required to register on the Progea web site to download this new version.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Progea has updated and fixed the vulnerability in Movicon Version \n11.4.1150. This is available as a download from the Progea Technical \nSupport site:\u00a0 http://www.progea.com/it-it/downloads/software.aspx \u00a0.\n\n\nUsers will be required to register on the Progea web site to download this new version."
            }
          ],
          "source": {
            "advisory": "ICSA-14-105-01",
            "discovery": "EXTERNAL"
          },
          "title": "Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-0778",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TCPUploader module in Progea Movicon 11.4 before 11.4.1150 allows remote attackers to obtain potentially sensitive version information via network traffic to TCP port 10651."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-105-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-0778",
        "datePublished": "2014-04-19T19:00:00.000Z",
        "dateReserved": "2014-01-02T00:00:00.000Z",
        "dateUpdated": "2025-09-24T21:24:10.830Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-1804 (GCVE-0-2012-1804)

    Vulnerability from cvelistv5 – Published: 2012-05-14 20:00 – Updated: 2024-08-06 19:08
    VLAI
    Summary
    The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://secunia.com/advisories/49092 third-party-advisoryx_refsource_SECUNIA
    http://osvdb.org/81814 vdb-entryx_refsource_OSVDB
    http://www.securityfocus.com/bid/53484 vdb-entryx_refsource_BID
    Date Public
    2012-05-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T19:08:38.508Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
              },
              {
                "name": "49092",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/49092"
              },
              {
                "name": "81814",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/81814"
              },
              {
                "name": "53484",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/53484"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2012-05-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-05-30T09:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
            },
            {
              "name": "49092",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/49092"
            },
            {
              "name": "81814",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/81814"
            },
            {
              "name": "53484",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/53484"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-1804",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-01.pdf"
                },
                {
                  "name": "49092",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/49092"
                },
                {
                  "name": "81814",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/81814"
                },
                {
                  "name": "53484",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/53484"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-1804",
        "datePublished": "2012-05-14T20:00:00.000Z",
        "dateReserved": "2012-03-21T00:00:00.000Z",
        "dateUpdated": "2024-08-06T19:08:38.508Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3498 (GCVE-0-2011-3498)

    Vulnerability from cvelistv5 – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.482Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "movicon-packets-bo(69788)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "movicon-packets-bo(69788)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3498",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "movicon-packets-bo(69788)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69788"
                },
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3498",
        "datePublished": "2011-09-16T17:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3499 (GCVE-0-2011-3499)

    Vulnerability from cvelistv5 – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.866Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
              },
              {
                "name": "movicon-eidp-dos(69789)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
            },
            {
              "name": "movicon-eidp-dos(69789)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3499",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_3-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_3-adv.txt"
                },
                {
                  "name": "movicon-eidp-dos(69789)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69789"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3499",
        "datePublished": "2011-09-16T17:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.866Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-3491 (GCVE-0-2011-3491)

    Vulnerability from cvelistv5 – Published: 2011-09-16 14:00 – Updated: 2024-08-06 23:37
    VLAI
    Summary
    Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Date Public
    2011-09-13 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:37:47.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
              },
              {
                "name": "movicon-contentlength-bo(69787)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
              },
              {
                "name": "75494",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://osvdb.org/75494"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-09-13T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
            },
            {
              "name": "movicon-contentlength-bo(69787)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
            },
            {
              "name": "75494",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://osvdb.org/75494"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-3491",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://aluigi.altervista.org/adv/movicon_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.altervista.org/adv/movicon_1-adv.txt"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-01.pdf"
                },
                {
                  "name": "movicon-contentlength-bo(69787)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69787"
                },
                {
                  "name": "75494",
                  "refsource": "OSVDB",
                  "url": "http://osvdb.org/75494"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-3491",
        "datePublished": "2011-09-16T14:00:00.000Z",
        "dateReserved": "2011-09-16T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:37:47.655Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-2963 (GCVE-0-2011-2963)

    Vulnerability from cvelistv5 – Published: 2011-07-29 19:00 – Updated: 2024-09-16 23:01
    VLAI
    Summary
    TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:15:32.035Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "46907",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/46907"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
              },
              {
                "name": "72888",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/72888"
              },
              {
                "name": "17034",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/17034"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2011-07-29T19:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "46907",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/46907"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
            },
            {
              "name": "72888",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/72888"
            },
            {
              "name": "17034",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/17034"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-2963",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "46907",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/46907"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01A.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-056-01.pdf"
                },
                {
                  "name": "72888",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/72888"
                },
                {
                  "name": "17034",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/17034"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-2963",
        "datePublished": "2011-07-29T19:00:00.000Z",
        "dateReserved": "2011-07-29T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:01:24.729Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }