Search
Find a vulnerability
Search criteria
40 vulnerabilities by IETF
CVE-2025-27371 (GCVE-0-2025-27371)
Vulnerability from nvd – Published: 2025-03-03 00:00 – Updated: 2025-04-25 14:42
VLAI
EPSS
VEX
Summary
In certain IETF OAuth 2.0-related specifications, when the JSON Web Token Profile for OAuth 2.0 Client Authentication mechanism is used, there are ambiguities in the audience values of JWTs sent to authorization servers. The affected RFCs may include RFC 7523, and also RFC 7521, RFC 7522, RFC 9101 (JAR), and RFC 9126 (PAR).
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-04 16:49 UTC
CWE
- CWE-305 - Authentication Bypass by Primary Weakness
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-04T16:49:31.778471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-04T16:49:57.268Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RFC 7523",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "7523",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In certain IETF OAuth 2.0-related specifications, when the JSON Web Token Profile for OAuth 2.0 Client Authentication mechanism is used, there are ambiguities in the audience values of JWTs sent to authorization servers. The affected RFCs may include RFC 7523, and also RFC 7521, RFC 7522, RFC 9101 (JAR), and RFC 9126 (PAR)."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305 Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-25T14:42:06.366Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://openid.net/wp-content/uploads/2025/01/OIDF-Responsible-Disclosure-Notice-on-Security-Vulnerability-for-private_key_jwt.pdf"
},
{
"url": "https://openid.net/notice-of-a-security-vulnerability/"
},
{
"url": "https://talks.secworkshop.events/osw2025/talk/R8D9BS/"
},
{
"url": "https://github.com/OWASP/ASVS/issues/2678"
},
{
"url": "https://eprint.iacr.org/2025/629"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-27371",
"datePublished": "2025-03-03T00:00:00.000Z",
"dateReserved": "2025-02-23T00:00:00.000Z",
"dateUpdated": "2025-04-25T14:42:06.366Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7596 (GCVE-0-2024-7596)
Vulnerability from nvd – Published: 2025-02-05 17:37 – Updated: 2025-11-03 20:56
VLAI
EPSS
VEX
Title
Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet
Summary
Proposed Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.
This can be considered similar to CVE-2020-10136.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 18:59 UTC
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | draft-ietf-intarea-gue-09 |
Affected:
GUE-09
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-7596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T18:59:09.631255Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:24:39.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:56:27.654Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "draft-ietf-intarea-gue-09",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "GUE-09"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Proposed Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.\r\n\r\nThis can be considered similar to CVE-2020-10136."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T17:37:33.876Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-intarea-gue/"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc6169.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet",
"x_generator": {
"engine": "VINCE 3.0.11",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-7596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-7596",
"datePublished": "2025-02-05T17:37:33.876Z",
"dateReserved": "2024-08-07T20:17:30.815Z",
"dateUpdated": "2025-11-03T20:56:27.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-7595 (GCVE-0-2024-7595)
Vulnerability from nvd – Published: 2025-02-05 17:36 – Updated: 2025-11-03 20:56
VLAI
EPSS
VEX
Title
GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet
Summary
GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.
This can be considered similar to CVE-2020-10136.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 19:00 UTC
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | RFC2784 - Generic Routing Encapsulation (GRE) |
Affected:
STD 1
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-7595",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:00:42.995220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:24:58.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:56:26.123Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RFC2784 - Generic Routing Encapsulation (GRE)",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "STD 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.\r\n\r\nThis can be considered similar to CVE-2020-10136."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T17:36:33.199Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2784"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc6169.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet",
"x_generator": {
"engine": "VINCE 3.0.11",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-7595"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-7595",
"datePublished": "2025-02-05T17:36:33.199Z",
"dateReserved": "2024-08-07T20:16:05.030Z",
"dateUpdated": "2025-11-03T20:56:26.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23019 (GCVE-0-2025-23019)
Vulnerability from nvd – Published: 2025-01-14 00:00 – Updated: 2025-11-03 21:00
VLAI
EPSS
VEX
Summary
IPv6-in-IPv4 tunneling (RFC 4213) allows an attacker to spoof and route traffic via an exposed network interface.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 19:37 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:37:11.123417Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.419Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:14.906Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv6-in-IPv4 tunneling (RFC 4213) allows an attacker to spoof and route traffic via an exposed network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:54:56.202Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc4213"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23019",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:14.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23018 (GCVE-0-2025-23018)
Vulnerability from nvd – Published: 2025-01-14 00:00 – Updated: 2025-11-03 21:00
VLAI
EPSS
VEX
Summary
IPv4-in-IPv6 and IPv6-in-IPv6 tunneling (RFC 2473) do not require the validation or verification of the source of a network packet, allowing an attacker to spoof and route arbitrary traffic via an exposed network interface. This is a similar issue to CVE-2020-10136.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 19:38 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23018",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:38:35.023118Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.585Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:13.443Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv4-in-IPv6 and IPv6-in-IPv6 tunneling (RFC 2473) do not require the validation or verification of the source of a network packet, allowing an attacker to spoof and route arbitrary traffic via an exposed network interface. This is a similar issue to CVE-2020-10136."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:51:42.363Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2473"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23018",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:13.443Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-3596 (GCVE-0-2024-3596)
Vulnerability from nvd – Published: 2024-07-09 12:02 – Updated: 2026-06-09 09:01
VLAI
EPSS
VEX
Title
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-11 03:55 UTC
CWE
Assigner
References
13 references
Impacted products
478 products
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | RFC |
Affected:
2865
|
|
| ietf | rfc |
Affected:
2865
cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:* |
|
| Siemens | CPC80 Central Processing/Communication |
Affected:
0 , < V16.51
(custom)
|
|
| Siemens | CPCI85 Central Processing/Communication |
Affected:
0 , < V6.20
(custom)
|
|
| Siemens | POWER METER SICAM Q100 family |
Affected:
0 , < V2.70
(custom)
|
|
| Siemens | POWER METER SICAM Q200 family |
Affected:
0 , < V2.83
(custom)
|
|
| Siemens | Powerlink IP |
Affected:
0 , < V4.22
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM CROSSBOW |
Affected:
0 , < V5.6
(custom)
|
|
| Siemens | RUGGEDCOM i800 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i800NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RMC30 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC30NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000RE |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1400 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1500 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1501 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1510 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1511 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1512 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1524 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1536 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM RP110 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RP110NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600F |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600FNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS8000 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000A |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000ANC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000H |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000HNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GP |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GPNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG907R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG908C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG909R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG910C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910NC |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2428P |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | RUGGEDCOM RST916C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST916P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | SCALANCE M804PB |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M826-2 SHDSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-2 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 3G-Router (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 (ROK) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (NAM) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (RoW) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 EEC LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 EEC M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2IA M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE WAB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 iFeatures |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X304-2FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X306-1LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH+ |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M PoE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M TS |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1 FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1-2LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X408-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XB205-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 SC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 ST |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE EEC (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G (EIP DEF.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G (EIP def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC316-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC332 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC416-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC424-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC432 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XCH328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM324 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM332 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XF204 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204 DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XM408-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XP208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216POE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216PoE EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR302-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR322-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M TS (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE TS (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 x FE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 X FE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG (without UL) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR326-8 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR502-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR522-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8WG |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XRH334 (24 V DC, 8xFO, CC) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SICAM AK 3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM BC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge (Classic) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge Applications for SICAM 8 Platform |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridPass |
Affected:
0 , < V2.50
(custom)
|
|
| Siemens | SICAM TM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICORE Base system |
Affected:
0 , < V2.20.0
(custom)
|
|
| Siemens | SINEC INS |
Affected:
0 , < V1.0 SP2 Update 4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPROTEC 5 - CP200 Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD84 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 6MU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) V9.8x |
Affected:
0 , < V9.83
(custom)
|
|
| Siemens | SIPROTEC 5 7SX82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SY82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UM85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 Compact 7SX800 (CP050) |
Affected:
0 , < V10.0
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rfc",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T03:55:37.141738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-04T21:05:25.373Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:52.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
},
{
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"tags": [
"x_transferred"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.blastradius.fail/"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"url": "https://www.kb.cert.org/vuls/id/456537"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "CPC80 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.51",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CPCI85 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q200 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Powerlink IP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.22",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM CROSSBOW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600F",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600FNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000ANC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000H",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000HNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GPNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG907R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG908C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG909R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG910C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2428P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3 3G-Router (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X304-2FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X306-1LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1 FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1-2LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 SC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC316-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC416-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC424-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC432",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCH328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM324",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216PoE EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM AK 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM BC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge (Classic)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge Applications for SICAM 8 Platform",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridPass",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM TM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICORE Base system",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.20.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC INS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0 SP2 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 - CP200 Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T09:01:52.617Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "RFC",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"
}
],
"descriptions": [
{
"lang": "en",
"value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-328: Use of Weak Hash",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T17:29:16.788Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"url": "https://www.blastradius.fail/"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT for SIPROTEC, SICAM and related product",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.",
"x_generator": {
"engine": "VINCE 3.0.4",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-3596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-3596",
"datePublished": "2024-07-09T12:02:53.001Z",
"dateReserved": "2024-04-10T15:09:45.391Z",
"dateUpdated": "2026-06-09T09:01:52.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-39920 (GCVE-0-2024-39920)
Vulnerability from nvd – Published: 2024-07-03 00:00 – Updated: 2024-08-05 18:37
VLAI
EPSS
VEX
Summary
The TCP protocol in RFC 9293 has a timing side channel that makes it easier for remote attackers to infer the content of one TCP connection from a client system (to any server), when that client system is concurrently obtaining TCP data at a slow rate from an attacker-controlled server, aka the "SnailLoad" issue. For example, the attack can begin by measuring RTTs via the TCP segments whose role is to provide an ACK control bit and an Acknowledgment Number.
Severity
4.3 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-05 18:27 UTC
CWE
- n/a
- CWE-1255 - Comparison Logic is Vulnerable to Power Side-Channel Attacks
Assigner
References
8 references
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:10.876Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.snailload.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.snailload.com/snailload.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/IAIK/SnailLoad"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.rfc-editor.org/rfc/rfc9293.txt"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tugraz.at/en/tu-graz/services/news-stories/tu-graz-news/singleview/article/neue-sicherheitsluecke-erlaubt-ueberwachung-besuchter-websites-und-angesehener-videos"
},
{
"tags": [
"x_transferred"
],
"url": "https://twitter.com/tugraz/status/1805272833322299412"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40809629"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.instagram.com/p/C8wpO1UtExw/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:tcp:9293:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tcp",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "9293"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-39920",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T18:27:41.004792Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1255",
"description": "CWE-1255 Comparison Logic is Vulnerable to Power Side-Channel Attacks",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T18:37:40.784Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The TCP protocol in RFC 9293 has a timing side channel that makes it easier for remote attackers to infer the content of one TCP connection from a client system (to any server), when that client system is concurrently obtaining TCP data at a slow rate from an attacker-controlled server, aka the \"SnailLoad\" issue. For example, the attack can begin by measuring RTTs via the TCP segments whose role is to provide an ACK control bit and an Acknowledgment Number."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T04:08:03.460Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.snailload.com"
},
{
"url": "https://www.snailload.com/snailload.pdf"
},
{
"url": "https://github.com/IAIK/SnailLoad"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc9293.txt"
},
{
"url": "https://www.tugraz.at/en/tu-graz/services/news-stories/tu-graz-news/singleview/article/neue-sicherheitsluecke-erlaubt-ueberwachung-besuchter-websites-und-angesehener-videos"
},
{
"url": "https://twitter.com/tugraz/status/1805272833322299412"
},
{
"url": "https://news.ycombinator.com/item?id=40809629"
},
{
"url": "https://www.instagram.com/p/C8wpO1UtExw/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-39920",
"datePublished": "2024-07-03T00:00:00.000Z",
"dateReserved": "2024-07-03T00:00:00.000Z",
"dateUpdated": "2024-08-05T18:37:40.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3661 (GCVE-0-2024-3661)
Vulnerability from nvd – Published: 2024-05-06 18:31 – Updated: 2024-08-28 19:09
VLAI
EPSS
VEX
Title
DHCP routing options can manipulate interface-based VPN traffic
Summary
DHCP can add routes to a client’s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-08 04:00 UTC
References
20 references
Date Public
2002-12-31 01:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:00.420Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2131#section-7"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc3442#section-7"
},
{
"tags": [
"x_transferred"
],
"url": "https://tunnelvisionbug.com/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.leviathansecurity.com/research/tunnelvision"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40279632"
},
{
"tags": [
"x_transferred"
],
"url": "https://arstechnica.com/security/2024/05/novel-attack-against-virtually-all-vpn-apps-neuters-their-entire-purpose/"
},
{
"tags": [
"x_transferred"
],
"url": "https://krebsonsecurity.com/2024/05/why-your-vpn-may-not-be-as-secure-as-it-claims/"
},
{
"tags": [
"x_transferred"
],
"url": "https://issuetracker.google.com/issues/263721377"
},
{
"tags": [
"x_transferred"
],
"url": "https://mullvad.net/en/blog/evaluating-the-impact-of-tunnelvision"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.zscaler.com/blogs/security-research/cve-2024-3661-k-tunnelvision-exposes-vpn-bypass-vulnerability"
},
{
"tags": [
"x_transferred"
],
"url": "https://lowendtalk.com/discussion/188857/a-rogue-dhcp-server-within-your-network-can-and-will-hijack-your-vpn-traffic"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40284111"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.agwa.name/blog/post/hardening_openvpn_for_def_con"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.theregister.com/2024/05/07/vpn_tunnelvision_dhcp/"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.citrix.com/article/CTX677069/cloud-software-group-security-advisory-for-cve20243661"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2024-00009"
},
{
"tags": [
"x_transferred"
],
"url": "https://bst.cisco.com/quickview/bug/CSCwk05814"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2024-3661"
},
{
"tags": [
"x_transferred"
],
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-170"
},
{
"tags": [
"x_transferred"
],
"url": "https://my.f5.com/manage/s/article/K000139553"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3661",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T04:00:07.962328Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T19:09:06.995Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "DHCP",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "0"
}
]
}
],
"datePublic": "2002-12-31T01:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "DHCP can add routes to a client\u2019s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN."
}
],
"value": "DHCP can add routes to a client\u2019s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-501",
"description": "CWE-501 Trust Boundary Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-01T15:04:50.790Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2131#section-7"
},
{
"url": "https://datatracker.ietf.org/doc/html/rfc3442#section-7"
},
{
"url": "https://tunnelvisionbug.com/"
},
{
"url": "https://www.leviathansecurity.com/research/tunnelvision"
},
{
"url": "https://news.ycombinator.com/item?id=40279632"
},
{
"url": "https://arstechnica.com/security/2024/05/novel-attack-against-virtually-all-vpn-apps-neuters-their-entire-purpose/"
},
{
"url": "https://krebsonsecurity.com/2024/05/why-your-vpn-may-not-be-as-secure-as-it-claims/"
},
{
"url": "https://issuetracker.google.com/issues/263721377"
},
{
"url": "https://mullvad.net/en/blog/evaluating-the-impact-of-tunnelvision"
},
{
"url": "https://www.zscaler.com/blogs/security-research/cve-2024-3661-k-tunnelvision-exposes-vpn-bypass-vulnerability"
},
{
"url": "https://lowendtalk.com/discussion/188857/a-rogue-dhcp-server-within-your-network-can-and-will-hijack-your-vpn-traffic"
},
{
"url": "https://news.ycombinator.com/item?id=40284111"
},
{
"url": "https://www.agwa.name/blog/post/hardening_openvpn_for_def_con"
},
{
"url": "https://www.theregister.com/2024/05/07/vpn_tunnelvision_dhcp/"
},
{
"url": "https://support.citrix.com/article/CTX677069/cloud-software-group-security-advisory-for-cve20243661"
},
{
"url": "https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2024-00009"
},
{
"url": "https://bst.cisco.com/quickview/bug/CSCwk05814"
},
{
"url": "https://security.paloaltonetworks.com/CVE-2024-3661"
},
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-170"
},
{
"url": "https://my.f5.com/manage/s/article/K000139553"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DHCP routing options can manipulate interface-based VPN traffic",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2024-3661",
"datePublished": "2024-05-06T18:31:21.217Z",
"dateReserved": "2024-04-11T17:24:22.637Z",
"dateUpdated": "2024-08-28T19:09:06.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44487 (GCVE-0-2023-44487)
Vulnerability from nvd – Published: 2023-10-10 00:00 – Updated: 2026-07-14 12:03Summary
The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.
Severity
7.5 (High)
SSVC
Exploitation: active
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 20:34 UTC
CWE
- n/a
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
173 references
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| ietf | http |
Affected:
2.0
cpe:2.3:a:ietf:http:2.0:*:*:*:*:*:*:* |
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SINEC NMS |
Affected:
0 , < V3.0
(custom)
|
|
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:http:2.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "http",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-44487",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T20:34:21.334116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2023-10-10",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-44487"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:05:35.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-44487"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-10-10T00:00:00.000Z",
"value": "CVE-2023-44487 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T21:08:27.383Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/dotnet/core/blob/e4613450ea0da7fd2fc6b61dfb2c1c1dec1ce9ec/release-notes/6.0/6.0.23/6.0.23.md?plain=1#L73"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.cloudflare.com/technical-breakdown-http2-rapid-reset-ddos-attack/"
},
{
"tags": [
"x_transferred"
],
"url": "https://aws.amazon.com/security/security-bulletins/AWS-2023-011/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cloud.google.com/blog/products/identity-security/how-it-works-the-novel-http2-rapid-reset-ddos-attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.nginx.com/blog/http-2-rapid-reset-attack-impacting-f5-nginx-products/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cloud.google.com/blog/products/identity-security/google-cloud-mitigated-largest-ddos-attack-peaking-above-398-million-rps/"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37831062"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.cloudflare.com/zero-day-rapid-reset-http2-record-breaking-ddos-attack/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.phoronix.com/news/HTTP2-Rapid-Reset-Attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/envoyproxy/envoy/pull/30055"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/haproxy/haproxy/issues/2312"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/eclipse/jetty.project/issues/10679"
},
{
"tags": [
"x_transferred"
],
"url": "https://forums.swift.org/t/swift-nio-http2-security-update-cve-2023-44487-http-2-dos/67764"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nghttp2/nghttp2/pull/1961"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/netty/netty/commit/58f75f665aa81a8cbcf6ffa74820042a285c5e61"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/alibaba/tengine/issues/1872"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/tomcat/tree/main/java/org/apache/coyote/http2"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37830987"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37830998"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/caddyserver/caddy/issues/5877"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.bleepingcomputer.com/news/security/new-http-2-rapid-reset-zero-day-attack-breaks-ddos-records/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/bcdannyboy/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/grpc/grpc-go/pull/6703"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/icing/mod_h2/blob/0a864782af0a942aa2ad4ed960a6b32cd35bcf0a/mod_http2/README.md?plain=1#L239-L244"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nghttp2/nghttp2/releases/tag/v1.57.0"
},
{
"tags": [
"x_transferred"
],
"url": "https://mailman.nginx.org/pipermail/nginx-devel/2023-October/S36Q5HBXR7CAIMPLLPRSSSYR4PCMWILK.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://my.f5.com/manage/s/article/K000137106"
},
{
"tags": [
"x_transferred"
],
"url": "https://msrc.microsoft.com/blog/2023/10/microsoft-response-to-distributed-denial-of-service-ddos-attacks-against-http/2/"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.proxmox.com/show_bug.cgi?id=4988"
},
{
"tags": [
"x_transferred"
],
"url": "https://cgit.freebsd.org/ports/commit/?id=c64c329c2c1752f46b73e3e6ce9f4329be6629f9"
},
{
"tags": [
"x_transferred"
],
"url": "https://seanmonstar.com/post/730794151136935936/hyper-http2-rapid-reset-unaffected"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/microsoft/CBL-Mariner/pull/6381"
},
{
"tags": [
"x_transferred"
],
"url": "https://groups.google.com/g/golang-announce/c/iNNxDTCjZvo"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/facebook/proxygen/pull/466"
},
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/adulau/7c2bfb8e9cdbe4b35a5e131c66a0c088"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/micrictor/http2-rst-stream"
},
{
"tags": [
"x_transferred"
],
"url": "https://edg.io/lp/blog/resets-leaks-ddos-and-the-tale-of-a-hidden-cve"
},
{
"tags": [
"x_transferred"
],
"url": "https://openssf.org/blog/2023/10/10/http-2-rapid-reset-vulnerability-highlights-need-for-rapid-response/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/h2o/h2o/security/advisories/GHSA-2m7v-gc89-fjqf"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/h2o/h2o/pull/3291"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nodejs/node/pull/50121"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/dotnet/announcements/issues/277"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/golang/go/issues/63417"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-vx74-f528-fxqg"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/trafficserver/pull/10564"
},
{
"tags": [
"x_transferred"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://tomcat.apache.org/security-10.html#Fixed_in_Apache_Tomcat_10.1.14"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.apache.org/thread/5py8h42mxfsn8l1wy6o41xwhsjlsd87q"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.haproxy.com/blog/haproxy-is-not-affected-by-the-http-2-rapid-reset-attack-cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/opensearch-project/data-prepper/issues/3474"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kubernetes/kubernetes/pull/121120"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/oqtane/oqtane.framework/discussions/3367"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-xpw8-rcwv-8f8p"
},
{
"tags": [
"x_transferred"
],
"url": "https://netty.io/news/2023/10/10/4-1-100-Final.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/10/10/http2-rapid-reset-vulnerability-cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.theregister.com/2023/10/10/http2_rapid_reset_zeroday/"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.qualys.com/vulnerabilities-threat-research/2023/10/10/cve-2023-44487-http-2-rapid-reset-attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37837043"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kazu-yamamoto/http2/issues/93"
},
{
"tags": [
"x_transferred"
],
"url": "https://martinthomson.github.io/h2-stream-limits/draft-thomson-httpbis-h2-stream-limits.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kazu-yamamoto/http2/commit/f61d41a502bd0f60eb24e1ce14edc7b6df6722a1"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/httpd/blob/afcdbeebbff4b0c50ea26cdd16e178c0d1f24152/modules/http2/h2_mplx.c#L1101-L1113"
},
{
"name": "DSA-5522",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5522"
},
{
"name": "DSA-5521",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5521"
},
{
"tags": [
"x_transferred"
],
"url": "https://access.redhat.com/security/cve/cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/ninenines/cowboy/issues/1615"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/varnishcache/varnish-cache/issues/3996"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/tempesta-tech/tempesta/issues/1986"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.vespa.ai/cve-2023-44487/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/etcd-io/etcd/issues/16740"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.darkreading.com/cloud/internet-wide-zero-day-bug-fuels-largest-ever-ddos-event"
},
{
"tags": [
"x_transferred"
],
"url": "https://istio.io/latest/news/security/istio-security-2023-004/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/junkurihara/rust-rpxy/issues/97"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1216123"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2242803"
},
{
"tags": [
"x_transferred"
],
"url": "https://ubuntu.com/security/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://community.traefik.io/t/is-traefik-vulnerable-to-cve-2023-44487/20125"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-qppj-fm5r-hxr3"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/httpd-site/pull/10"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/projectcontour/contour/pull/5826"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/linkerd/website/pull/1695/commits/4b9c6836471bc8270ab48aae6fd2181bc73fd632"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/line/armeria/pull/5232"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.litespeedtech.com/2023/10/11/rapid-reset-http-2-vulnerablilty/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/akka/akka-http/issues/4323"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/openresty/openresty/issues/930"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/apisix/issues/10320"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Azure/AKS/issues/3947"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Kong/kong/discussions/11741"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/arkrwn/PoC/tree/main/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.netlify.com/blog/netlify-successfully-mitigates-cve-2023-44487/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/caddyserver/caddy/releases/tag/v2.7.5"
},
{
"name": "[debian-lts-announce] 20231013 [SECURITY] [DLA 3617-1] tomcat9 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00020.html"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/4"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/9"
},
{
"tags": [
"x_transferred"
],
"url": "https://arstechnica.com/security/2023/10/how-ddosers-used-the-http-2-protocol-to-deliver-attacks-of-unprecedented-size/"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.w3.org/Archives/Public/ietf-http-wg/2023OctDec/0025.html"
},
{
"name": "FEDORA-2023-ed2642fd58",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JMEXY22BFG5Q64HQCM5CK2Q7KDKVV4TY/"
},
{
"tags": [
"x_transferred"
],
"url": "https://linkerd.io/2023/10/12/linkerd-cve-2023-44487/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3621-1] nghttp2 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00023.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20231016-0001/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3617-2] tomcat9 regression update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00024.html"
},
{
"name": "[oss-security] 20231018 Vulnerability in Jenkins",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/4"
},
{
"name": "[oss-security] 20231018 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/8"
},
{
"name": "[oss-security] 20231019 CVE-2023-45802: Apache HTTP Server: HTTP/2 stream memory not reclaimed right away on RST",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/19/6"
},
{
"name": "FEDORA-2023-54fadada12",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZKQSIKIAT5TJ3WSLU3RDBQ35YX4GY4V3/"
},
{
"name": "FEDORA-2023-5ff7bf1dd8",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JIZSEFC3YKCGABA2BZW6ZJRMDZJMB7PJ/"
},
{
"name": "[oss-security] 20231020 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/20/8"
},
{
"name": "FEDORA-2023-17efd3f2cd",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WLPRQ5TWUQQXYWBJM7ECYDAIL2YVKIUH/"
},
{
"name": "FEDORA-2023-d5030c983c",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/E72T67UPDRXHIDLO3OROR25YAMN4GGW5/"
},
{
"name": "FEDORA-2023-0259c3f26f",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BFQD3KUEMFBHPAPBGLWQC34L4OWL5HAZ/"
},
{
"name": "FEDORA-2023-2a9214af5f",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZLU6U2R2IC2K64NDPNMV55AUAO65MAF4/"
},
{
"name": "FEDORA-2023-e9c04d81c1",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X6QXN4ORIVF6XBW4WWFE7VNPVC74S45Y/"
},
{
"name": "FEDORA-2023-f66fc0f62a",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LKYHSZQFDNR7RSA7LHVLLIAQMVYCUGBG/"
},
{
"name": "FEDORA-2023-4d2fd884ea",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/FNA62Q767CFAFHBCDKYNPBMZWB7TWYVU/"
},
{
"name": "FEDORA-2023-b2c50535cb",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LNMZJCDHGLJJLXO4OXWJMTVQRNWOC7UL/"
},
{
"name": "FEDORA-2023-fe53e13b5b",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/KSEGD2IWKNUO3DWY4KQGUQM5BISRWHQE/"
},
{
"name": "FEDORA-2023-4bf641255e",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CLB4TW7KALB3EEQWNWCN7OUIWWVWWCG2/"
},
{
"name": "[debian-lts-announce] 20231030 [SECURITY] [DLA 3641-1] jetty9 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00045.html"
},
{
"name": "DSA-5540",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5540"
},
{
"name": "[debian-lts-announce] 20231031 [SECURITY] [DLA 3638-1] h2o security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00047.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://discuss.hashicorp.com/t/hcsec-2023-32-vault-consul-and-boundary-affected-by-http-2-rapid-reset-denial-of-service-vulnerability-cve-2023-44487/59715"
},
{
"name": "FEDORA-2023-1caffb88af",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VHUHTSXLXGXS7JYKBXTA3VINUPHTNGVU/"
},
{
"name": "FEDORA-2023-3f70b8d406",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VSRDIV77HNKUSM7SJC5BKE5JSHLHU2NK/"
},
{
"name": "FEDORA-2023-7b52921cae",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3N4NJ7FR4X4FPZUGNTQAPSTVB2HB2Y4A/"
},
{
"name": "FEDORA-2023-7934802344",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZB43REMKRQR62NJEI7I5NQ4FSXNLBKRT/"
},
{
"name": "FEDORA-2023-dbe64661af",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/HT7T2R4MQKLIF4ODV4BDLPARWFPCJ5CZ/"
},
{
"name": "FEDORA-2023-822aab0a5a",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/XFOIBB4YFICHDM7IBOP7PWXW3FX4HLL2/"
},
{
"name": "[debian-lts-announce] 20231105 [SECURITY] [DLA 3645-1] trafficserver security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00001.html"
},
{
"name": "DSA-5549",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5549"
},
{
"name": "FEDORA-2023-c0c6a91330",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2MBEPPC36UBVOZZNAXFHKLFGSLCMN5LI/"
},
{
"name": "FEDORA-2023-492b7be466",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WE2I52RHNNU42PX6NZ2RBUHSFFJ2LVZX/"
},
{
"name": "DSA-5558",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5558"
},
{
"name": "[debian-lts-announce] 20231119 [SECURITY] [DLA 3656-1] netty security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00012.html"
},
{
"name": "GLSA-202311-09",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202311-09"
},
{
"name": "DSA-5570",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5570"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240426-0007/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0007/"
},
{
"url": "https://www.vicarius.io/vsociety/posts/rapid-reset-cve-2023-44487-dos-in-http2-understanding-the-root-cause"
},
{
"url": "http://www.openwall.com/lists/oss-security/2025/08/13/6"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:03:17.389Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-832273.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-341067.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-082556.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T20:05:34.376Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/dotnet/core/blob/e4613450ea0da7fd2fc6b61dfb2c1c1dec1ce9ec/release-notes/6.0/6.0.23/6.0.23.md?plain=1#L73"
},
{
"url": "https://blog.cloudflare.com/technical-breakdown-http2-rapid-reset-ddos-attack/"
},
{
"url": "https://aws.amazon.com/security/security-bulletins/AWS-2023-011/"
},
{
"url": "https://cloud.google.com/blog/products/identity-security/how-it-works-the-novel-http2-rapid-reset-ddos-attack"
},
{
"url": "https://www.nginx.com/blog/http-2-rapid-reset-attack-impacting-f5-nginx-products/"
},
{
"url": "https://cloud.google.com/blog/products/identity-security/google-cloud-mitigated-largest-ddos-attack-peaking-above-398-million-rps/"
},
{
"url": "https://news.ycombinator.com/item?id=37831062"
},
{
"url": "https://blog.cloudflare.com/zero-day-rapid-reset-http2-record-breaking-ddos-attack/"
},
{
"url": "https://www.phoronix.com/news/HTTP2-Rapid-Reset-Attack"
},
{
"url": "https://github.com/envoyproxy/envoy/pull/30055"
},
{
"url": "https://github.com/haproxy/haproxy/issues/2312"
},
{
"url": "https://github.com/eclipse/jetty.project/issues/10679"
},
{
"url": "https://forums.swift.org/t/swift-nio-http2-security-update-cve-2023-44487-http-2-dos/67764"
},
{
"url": "https://github.com/nghttp2/nghttp2/pull/1961"
},
{
"url": "https://github.com/netty/netty/commit/58f75f665aa81a8cbcf6ffa74820042a285c5e61"
},
{
"url": "https://github.com/alibaba/tengine/issues/1872"
},
{
"url": "https://github.com/apache/tomcat/tree/main/java/org/apache/coyote/http2"
},
{
"url": "https://news.ycombinator.com/item?id=37830987"
},
{
"url": "https://news.ycombinator.com/item?id=37830998"
},
{
"url": "https://github.com/caddyserver/caddy/issues/5877"
},
{
"url": "https://www.bleepingcomputer.com/news/security/new-http-2-rapid-reset-zero-day-attack-breaks-ddos-records/"
},
{
"url": "https://github.com/bcdannyboy/CVE-2023-44487"
},
{
"url": "https://github.com/grpc/grpc-go/pull/6703"
},
{
"url": "https://github.com/icing/mod_h2/blob/0a864782af0a942aa2ad4ed960a6b32cd35bcf0a/mod_http2/README.md?plain=1#L239-L244"
},
{
"url": "https://github.com/nghttp2/nghttp2/releases/tag/v1.57.0"
},
{
"url": "https://mailman.nginx.org/pipermail/nginx-devel/2023-October/S36Q5HBXR7CAIMPLLPRSSSYR4PCMWILK.html"
},
{
"url": "https://my.f5.com/manage/s/article/K000137106"
},
{
"url": "https://msrc.microsoft.com/blog/2023/10/microsoft-response-to-distributed-denial-of-service-ddos-attacks-against-http/2/"
},
{
"url": "https://bugzilla.proxmox.com/show_bug.cgi?id=4988"
},
{
"url": "https://cgit.freebsd.org/ports/commit/?id=c64c329c2c1752f46b73e3e6ce9f4329be6629f9"
},
{
"name": "[oss-security] 20231010 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/10/7"
},
{
"name": "[oss-security] 20231010 CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"url": "https://seanmonstar.com/post/730794151136935936/hyper-http2-rapid-reset-unaffected"
},
{
"url": "https://github.com/microsoft/CBL-Mariner/pull/6381"
},
{
"url": "https://groups.google.com/g/golang-announce/c/iNNxDTCjZvo"
},
{
"url": "https://github.com/facebook/proxygen/pull/466"
},
{
"url": "https://gist.github.com/adulau/7c2bfb8e9cdbe4b35a5e131c66a0c088"
},
{
"url": "https://github.com/micrictor/http2-rst-stream"
},
{
"url": "https://edg.io/lp/blog/resets-leaks-ddos-and-the-tale-of-a-hidden-cve"
},
{
"url": "https://openssf.org/blog/2023/10/10/http-2-rapid-reset-vulnerability-highlights-need-for-rapid-response/"
},
{
"url": "https://github.com/h2o/h2o/security/advisories/GHSA-2m7v-gc89-fjqf"
},
{
"url": "https://github.com/h2o/h2o/pull/3291"
},
{
"url": "https://github.com/nodejs/node/pull/50121"
},
{
"url": "https://github.com/dotnet/announcements/issues/277"
},
{
"url": "https://github.com/golang/go/issues/63417"
},
{
"url": "https://github.com/advisories/GHSA-vx74-f528-fxqg"
},
{
"url": "https://github.com/apache/trafficserver/pull/10564"
},
{
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-44487"
},
{
"url": "https://tomcat.apache.org/security-10.html#Fixed_in_Apache_Tomcat_10.1.14"
},
{
"url": "https://lists.apache.org/thread/5py8h42mxfsn8l1wy6o41xwhsjlsd87q"
},
{
"url": "https://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"url": "https://www.haproxy.com/blog/haproxy-is-not-affected-by-the-http-2-rapid-reset-attack-cve-2023-44487"
},
{
"url": "https://github.com/opensearch-project/data-prepper/issues/3474"
},
{
"url": "https://github.com/kubernetes/kubernetes/pull/121120"
},
{
"url": "https://github.com/oqtane/oqtane.framework/discussions/3367"
},
{
"url": "https://github.com/advisories/GHSA-xpw8-rcwv-8f8p"
},
{
"url": "https://netty.io/news/2023/10/10/4-1-100-Final.html"
},
{
"url": "https://www.cisa.gov/news-events/alerts/2023/10/10/http2-rapid-reset-vulnerability-cve-2023-44487"
},
{
"url": "https://www.theregister.com/2023/10/10/http2_rapid_reset_zeroday/"
},
{
"url": "https://blog.qualys.com/vulnerabilities-threat-research/2023/10/10/cve-2023-44487-http-2-rapid-reset-attack"
},
{
"url": "https://news.ycombinator.com/item?id=37837043"
},
{
"url": "https://github.com/kazu-yamamoto/http2/issues/93"
},
{
"url": "https://martinthomson.github.io/h2-stream-limits/draft-thomson-httpbis-h2-stream-limits.html"
},
{
"url": "https://github.com/kazu-yamamoto/http2/commit/f61d41a502bd0f60eb24e1ce14edc7b6df6722a1"
},
{
"url": "https://github.com/apache/httpd/blob/afcdbeebbff4b0c50ea26cdd16e178c0d1f24152/modules/http2/h2_mplx.c#L1101-L1113"
},
{
"name": "DSA-5522",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5522"
},
{
"name": "DSA-5521",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5521"
},
{
"url": "https://access.redhat.com/security/cve/cve-2023-44487"
},
{
"url": "https://github.com/ninenines/cowboy/issues/1615"
},
{
"url": "https://github.com/varnishcache/varnish-cache/issues/3996"
},
{
"url": "https://github.com/tempesta-tech/tempesta/issues/1986"
},
{
"url": "https://blog.vespa.ai/cve-2023-44487/"
},
{
"url": "https://github.com/etcd-io/etcd/issues/16740"
},
{
"url": "https://www.darkreading.com/cloud/internet-wide-zero-day-bug-fuels-largest-ever-ddos-event"
},
{
"url": "https://istio.io/latest/news/security/istio-security-2023-004/"
},
{
"url": "https://github.com/junkurihara/rust-rpxy/issues/97"
},
{
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1216123"
},
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2242803"
},
{
"url": "https://ubuntu.com/security/CVE-2023-44487"
},
{
"url": "https://community.traefik.io/t/is-traefik-vulnerable-to-cve-2023-44487/20125"
},
{
"url": "https://github.com/advisories/GHSA-qppj-fm5r-hxr3"
},
{
"url": "https://github.com/apache/httpd-site/pull/10"
},
{
"url": "https://github.com/projectcontour/contour/pull/5826"
},
{
"url": "https://github.com/linkerd/website/pull/1695/commits/4b9c6836471bc8270ab48aae6fd2181bc73fd632"
},
{
"url": "https://github.com/line/armeria/pull/5232"
},
{
"url": "https://blog.litespeedtech.com/2023/10/11/rapid-reset-http-2-vulnerablilty/"
},
{
"url": "https://security.paloaltonetworks.com/CVE-2023-44487"
},
{
"url": "https://github.com/akka/akka-http/issues/4323"
},
{
"url": "https://github.com/openresty/openresty/issues/930"
},
{
"url": "https://github.com/apache/apisix/issues/10320"
},
{
"url": "https://github.com/Azure/AKS/issues/3947"
},
{
"url": "https://github.com/Kong/kong/discussions/11741"
},
{
"url": "https://github.com/arkrwn/PoC/tree/main/CVE-2023-44487"
},
{
"url": "https://www.netlify.com/blog/netlify-successfully-mitigates-cve-2023-44487/"
},
{
"url": "https://github.com/caddyserver/caddy/releases/tag/v2.7.5"
},
{
"name": "[debian-lts-announce] 20231013 [SECURITY] [DLA 3617-1] tomcat9 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00020.html"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/4"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/9"
},
{
"url": "https://arstechnica.com/security/2023/10/how-ddosers-used-the-http-2-protocol-to-deliver-attacks-of-unprecedented-size/"
},
{
"url": "https://lists.w3.org/Archives/Public/ietf-http-wg/2023OctDec/0025.html"
},
{
"name": "FEDORA-2023-ed2642fd58",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/JMEXY22BFG5Q64HQCM5CK2Q7KDKVV4TY/"
},
{
"url": "https://linkerd.io/2023/10/12/linkerd-cve-2023-44487/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3621-1] nghttp2 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00023.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20231016-0001/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3617-2] tomcat9 regression update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00024.html"
},
{
"name": "[oss-security] 20231018 Vulnerability in Jenkins",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/4"
},
{
"name": "[oss-security] 20231018 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/8"
},
{
"name": "[oss-security] 20231019 CVE-2023-45802: Apache HTTP Server: HTTP/2 stream memory not reclaimed right away on RST",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/19/6"
},
{
"name": "FEDORA-2023-54fadada12",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZKQSIKIAT5TJ3WSLU3RDBQ35YX4GY4V3/"
},
{
"name": "FEDORA-2023-5ff7bf1dd8",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/JIZSEFC3YKCGABA2BZW6ZJRMDZJMB7PJ/"
},
{
"name": "[oss-security] 20231020 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/20/8"
},
{
"name": "FEDORA-2023-17efd3f2cd",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WLPRQ5TWUQQXYWBJM7ECYDAIL2YVKIUH/"
},
{
"name": "FEDORA-2023-d5030c983c",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/E72T67UPDRXHIDLO3OROR25YAMN4GGW5/"
},
{
"name": "FEDORA-2023-0259c3f26f",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/BFQD3KUEMFBHPAPBGLWQC34L4OWL5HAZ/"
},
{
"name": "FEDORA-2023-2a9214af5f",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZLU6U2R2IC2K64NDPNMV55AUAO65MAF4/"
},
{
"name": "FEDORA-2023-e9c04d81c1",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/X6QXN4ORIVF6XBW4WWFE7VNPVC74S45Y/"
},
{
"name": "FEDORA-2023-f66fc0f62a",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LKYHSZQFDNR7RSA7LHVLLIAQMVYCUGBG/"
},
{
"name": "FEDORA-2023-4d2fd884ea",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FNA62Q767CFAFHBCDKYNPBMZWB7TWYVU/"
},
{
"name": "FEDORA-2023-b2c50535cb",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LNMZJCDHGLJJLXO4OXWJMTVQRNWOC7UL/"
},
{
"name": "FEDORA-2023-fe53e13b5b",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/KSEGD2IWKNUO3DWY4KQGUQM5BISRWHQE/"
},
{
"name": "FEDORA-2023-4bf641255e",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/CLB4TW7KALB3EEQWNWCN7OUIWWVWWCG2/"
},
{
"name": "[debian-lts-announce] 20231030 [SECURITY] [DLA 3641-1] jetty9 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00045.html"
},
{
"name": "DSA-5540",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5540"
},
{
"name": "[debian-lts-announce] 20231031 [SECURITY] [DLA 3638-1] h2o security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00047.html"
},
{
"url": "https://discuss.hashicorp.com/t/hcsec-2023-32-vault-consul-and-boundary-affected-by-http-2-rapid-reset-denial-of-service-vulnerability-cve-2023-44487/59715"
},
{
"name": "FEDORA-2023-1caffb88af",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VHUHTSXLXGXS7JYKBXTA3VINUPHTNGVU/"
},
{
"name": "FEDORA-2023-3f70b8d406",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VSRDIV77HNKUSM7SJC5BKE5JSHLHU2NK/"
},
{
"name": "FEDORA-2023-7b52921cae",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/3N4NJ7FR4X4FPZUGNTQAPSTVB2HB2Y4A/"
},
{
"name": "FEDORA-2023-7934802344",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZB43REMKRQR62NJEI7I5NQ4FSXNLBKRT/"
},
{
"name": "FEDORA-2023-dbe64661af",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HT7T2R4MQKLIF4ODV4BDLPARWFPCJ5CZ/"
},
{
"name": "FEDORA-2023-822aab0a5a",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/XFOIBB4YFICHDM7IBOP7PWXW3FX4HLL2/"
},
{
"name": "[debian-lts-announce] 20231105 [SECURITY] [DLA 3645-1] trafficserver security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00001.html"
},
{
"name": "DSA-5549",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5549"
},
{
"name": "FEDORA-2023-c0c6a91330",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/2MBEPPC36UBVOZZNAXFHKLFGSLCMN5LI/"
},
{
"name": "FEDORA-2023-492b7be466",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WE2I52RHNNU42PX6NZ2RBUHSFFJ2LVZX/"
},
{
"name": "DSA-5558",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5558"
},
{
"name": "[debian-lts-announce] 20231119 [SECURITY] [DLA 3656-1] netty security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00012.html"
},
{
"name": "GLSA-202311-09",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202311-09"
},
{
"name": "DSA-5570",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5570"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240426-0007/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0007/"
},
{
"url": "https://github.com/grpc/grpc/releases/tag/v1.59.2"
},
{
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-http2-reset-d8Kf32vZ"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-44487",
"datePublished": "2023-10-10T00:00:00.000Z",
"dateReserved": "2023-09-29T00:00:00.000Z",
"dateUpdated": "2026-07-14T12:03:17.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27862 (GCVE-0-2021-27862)
Vulnerability from nvd – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with an invalid length during Ethernet to Wifi frame translation
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers).
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:04 UTC
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| IEEE | 802.2 |
Affected:
802.2h-1997 , ≤ 802.2h-1997
(custom)
|
|
| IETF | draft-ietf-v6ops-ra-guard-08 |
Affected:
08 , ≤ 08
(custom)
|
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:28.789Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27862",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:04:33.466068Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:04:40.862Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard-08",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-130",
"description": "CWE-130 Improper Handling of Length Parameter",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with an invalid length during Ethernet to Wifi frame translation"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27862",
"datePublished": "2022-09-27T18:40:14.712Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:28.789Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27861 (GCVE-0-2021-27861)
Vulnerability from nvd – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with invalid lengths
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length (and optionally VLAN0 headers)
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:06 UTC
Assigner
References
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:27.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27861",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:06:05.203947Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:06:11.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length (and optionally VLAN0 headers)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-130",
"description": "CWE-130 Improper Handling of Length Parameter",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with invalid lengths"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27861",
"datePublished": "2022-09-27T18:40:13.742Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:27.712Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27854 (GCVE-0-2021-27854)
Vulnerability from nvd – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0, LLC/SNAP headers, and Ethernet to Wifi frame translation
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using combinations of VLAN 0 headers, LLC/SNAP headers, and converting frames from Ethernet to Wifi and its reverse.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:06 UTC
CWE
- CWE-290 - Authentication Bypass by Spoofing
Assigner
References
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:26.598Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27854",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:06:23.882465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:06:44.230Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using combinations of VLAN 0 headers, LLC/SNAP headers, and converting frames from Ethernet to Wifi and its reverse."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0, LLC/SNAP headers, and Ethernet to Wifi frame translation"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27854",
"datePublished": "2022-09-27T18:40:12.738Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:26.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27853 (GCVE-0-2021-27853)
Vulnerability from nvd – Published: 2022-09-27 17:55 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering can be bypassed using stacked VLAN0 and LLC/SNAP headers
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard or ARP inspection can be bypassed using combinations of VLAN 0 headers and LLC/SNAP headers.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:26 UTC
CWE
- CWE-290 - Authentication Bypass by Spoofing
Assigner
References
7 references
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:25.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"name": "20220927 Vulnerabilities in Layer 2 Network Security Controls Affecting Cisco Products: September 2022",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-VU855201-J3z8CKTX"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27853",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:26:49.324466Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:27:39.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard or ARP inspection can be bypassed using combinations of VLAN 0 headers and LLC/SNAP headers."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"name": "20220927 Vulnerabilities in Layer 2 Network Security Controls Affecting Cisco Products: September 2022",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-VU855201-J3z8CKTX"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering can be bypassed using stacked VLAN0 and LLC/SNAP headers"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27853",
"datePublished": "2022-09-27T17:55:09.203Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:25.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-20949 (GCVE-0-2020-20949)
Vulnerability from nvd – Published: 2021-01-20 15:42 – Updated: 2026-07-09 00:09
VLAI
EPSS
VEX
Summary
Bleichenbacher's attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher's oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:09:53.140Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T15:47:56.997Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20949",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf",
"refsource": "MISC",
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"name": "http://st.com",
"refsource": "MISC",
"url": "http://st.com"
},
{
"name": "http://x-cube-cryptolib.com",
"refsource": "MISC",
"url": "http://x-cube-cryptolib.com"
},
{
"name": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html",
"refsource": "MISC",
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"name": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb",
"refsource": "MISC",
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20949",
"datePublished": "2021-01-20T15:42:18.000Z",
"dateReserved": "2020-08-13T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:09:53.140Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-20950 (GCVE-0-2020-20950)
Vulnerability from nvd – Published: 2021-01-19 12:22 – Updated: 2026-07-09 00:09
VLAI
EPSS
VEX
Summary
Bleichenbacher's attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher's oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:09:54.370Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-04T23:46:45.075Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20950",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf",
"refsource": "MISC",
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"name": "http://microchip.com",
"refsource": "MISC",
"url": "http://microchip.com"
},
{
"name": "https://www.microchip.com/mplab/microchip-libraries-for-applications",
"refsource": "MISC",
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"name": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb",
"refsource": "MISC",
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20950",
"datePublished": "2021-01-19T12:22:55.000Z",
"dateReserved": "2020-08-13T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:09:54.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-27371 (GCVE-0-2025-27371)
Vulnerability from cvelistv5 – Published: 2025-03-03 00:00 – Updated: 2025-04-25 14:42
VLAI
EPSS
VEX
Summary
In certain IETF OAuth 2.0-related specifications, when the JSON Web Token Profile for OAuth 2.0 Client Authentication mechanism is used, there are ambiguities in the audience values of JWTs sent to authorization servers. The affected RFCs may include RFC 7523, and also RFC 7521, RFC 7522, RFC 9101 (JAR), and RFC 9126 (PAR).
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-04 16:49 UTC
CWE
- CWE-305 - Authentication Bypass by Primary Weakness
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-04T16:49:31.778471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-04T16:49:57.268Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RFC 7523",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "7523",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In certain IETF OAuth 2.0-related specifications, when the JSON Web Token Profile for OAuth 2.0 Client Authentication mechanism is used, there are ambiguities in the audience values of JWTs sent to authorization servers. The affected RFCs may include RFC 7523, and also RFC 7521, RFC 7522, RFC 9101 (JAR), and RFC 9126 (PAR)."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305 Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-25T14:42:06.366Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://openid.net/wp-content/uploads/2025/01/OIDF-Responsible-Disclosure-Notice-on-Security-Vulnerability-for-private_key_jwt.pdf"
},
{
"url": "https://openid.net/notice-of-a-security-vulnerability/"
},
{
"url": "https://talks.secworkshop.events/osw2025/talk/R8D9BS/"
},
{
"url": "https://github.com/OWASP/ASVS/issues/2678"
},
{
"url": "https://eprint.iacr.org/2025/629"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-27371",
"datePublished": "2025-03-03T00:00:00.000Z",
"dateReserved": "2025-02-23T00:00:00.000Z",
"dateUpdated": "2025-04-25T14:42:06.366Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7596 (GCVE-0-2024-7596)
Vulnerability from cvelistv5 – Published: 2025-02-05 17:37 – Updated: 2025-11-03 20:56
VLAI
EPSS
VEX
Title
Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet
Summary
Proposed Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.
This can be considered similar to CVE-2020-10136.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 18:59 UTC
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | draft-ietf-intarea-gue-09 |
Affected:
GUE-09
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-7596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T18:59:09.631255Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:24:39.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:56:27.654Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "draft-ietf-intarea-gue-09",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "GUE-09"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Proposed Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.\r\n\r\nThis can be considered similar to CVE-2020-10136."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T17:37:33.876Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-intarea-gue/"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc6169.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Generic UDP Encapsulation (GUE) (IETF Draft) do not validate or verify the source of a network packet",
"x_generator": {
"engine": "VINCE 3.0.11",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-7596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-7596",
"datePublished": "2025-02-05T17:37:33.876Z",
"dateReserved": "2024-08-07T20:17:30.815Z",
"dateUpdated": "2025-11-03T20:56:27.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-7595 (GCVE-0-2024-7595)
Vulnerability from cvelistv5 – Published: 2025-02-05 17:36 – Updated: 2025-11-03 20:56
VLAI
EPSS
VEX
Title
GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet
Summary
GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.
This can be considered similar to CVE-2020-10136.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 19:00 UTC
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | RFC2784 - Generic Routing Encapsulation (GRE) |
Affected:
STD 1
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-7595",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:00:42.995220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:24:58.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:56:26.123Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RFC2784 - Generic Routing Encapsulation (GRE)",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "STD 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet allowing an attacker to spoof and route arbitrary traffic via an exposed network interface that can lead to spoofing, access control bypass, and other unexpected network behaviors.\r\n\r\nThis can be considered similar to CVE-2020-10136."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T17:36:33.199Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2784"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc6169.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "GRE and GRE6 Protocols (RFC2784) do not validate or verify the source of a network packet",
"x_generator": {
"engine": "VINCE 3.0.11",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-7595"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-7595",
"datePublished": "2025-02-05T17:36:33.199Z",
"dateReserved": "2024-08-07T20:16:05.030Z",
"dateUpdated": "2025-11-03T20:56:26.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23019 (GCVE-0-2025-23019)
Vulnerability from cvelistv5 – Published: 2025-01-14 00:00 – Updated: 2025-11-03 21:00
VLAI
EPSS
VEX
Summary
IPv6-in-IPv4 tunneling (RFC 4213) allows an attacker to spoof and route traffic via an exposed network interface.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 19:37 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:37:11.123417Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.419Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:14.906Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv6-in-IPv4 tunneling (RFC 4213) allows an attacker to spoof and route traffic via an exposed network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:54:56.202Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc4213"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23019",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:14.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23018 (GCVE-0-2025-23018)
Vulnerability from cvelistv5 – Published: 2025-01-14 00:00 – Updated: 2025-11-03 21:00
VLAI
EPSS
VEX
Summary
IPv4-in-IPv6 and IPv6-in-IPv6 tunneling (RFC 2473) do not require the validation or verification of the source of a network packet, allowing an attacker to spoof and route arbitrary traffic via an exposed network interface. This is a similar issue to CVE-2020-10136.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 19:38 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23018",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T19:38:35.023118Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:20.585Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:00:13.443Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/199397"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IPv6",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ietf:ipv6:*:*:*:*:*:*:*:*",
"versionEndIncluding": "6",
"versionStartIncluding": "6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IPv4-in-IPv6 and IPv6-in-IPv6 tunneling (RFC 2473) do not require the validation or verification of the source of a network packet, allowing an attacker to spoof and route arbitrary traffic via an exposed network interface. This is a similar issue to CVE-2020-10136."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T19:51:42.363Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2473"
},
{
"url": "https://papers.mathyvanhoef.com/usenix2025-tunnels.pdf"
},
{
"url": "https://www.top10vpn.com/research/tunneling-protocol-vulnerability/"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-23018",
"datePublished": "2025-01-14T00:00:00.000Z",
"dateReserved": "2025-01-10T00:00:00.000Z",
"dateUpdated": "2025-11-03T21:00:13.443Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-3596 (GCVE-0-2024-3596)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:02 – Updated: 2026-06-09 09:01
VLAI
EPSS
VEX
Title
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-11 03:55 UTC
CWE
Assigner
References
13 references
Impacted products
478 products
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | RFC |
Affected:
2865
|
|
| ietf | rfc |
Affected:
2865
cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:* |
|
| Siemens | CPC80 Central Processing/Communication |
Affected:
0 , < V16.51
(custom)
|
|
| Siemens | CPCI85 Central Processing/Communication |
Affected:
0 , < V6.20
(custom)
|
|
| Siemens | POWER METER SICAM Q100 family |
Affected:
0 , < V2.70
(custom)
|
|
| Siemens | POWER METER SICAM Q200 family |
Affected:
0 , < V2.83
(custom)
|
|
| Siemens | Powerlink IP |
Affected:
0 , < V4.22
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM CROSSBOW |
Affected:
0 , < V5.6
(custom)
|
|
| Siemens | RUGGEDCOM i800 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i800NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RMC30 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC30NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000RE |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1400 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1500 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1501 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1510 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1511 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1512 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1524 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1536 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM RP110 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RP110NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600F |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600FNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS8000 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000A |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000ANC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000H |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000HNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GP |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GPNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG907R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG908C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG909R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG910C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910NC |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2428P |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | RUGGEDCOM RST916C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST916P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | SCALANCE M804PB |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M826-2 SHDSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-2 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 3G-Router (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 (ROK) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (NAM) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (RoW) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 EEC LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 EEC M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2IA M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE WAB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 iFeatures |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X304-2FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X306-1LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH+ |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M PoE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M TS |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1 FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1-2LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X408-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XB205-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 SC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 ST |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE EEC (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G (EIP DEF.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G (EIP def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC316-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC332 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC416-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC424-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC432 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XCH328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM324 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM332 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XF204 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204 DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XM408-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XP208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216POE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216PoE EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR302-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR322-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M TS (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE TS (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 x FE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 X FE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG (without UL) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR326-8 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR502-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR522-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8WG |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XRH334 (24 V DC, 8xFO, CC) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SICAM AK 3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM BC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge (Classic) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge Applications for SICAM 8 Platform |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridPass |
Affected:
0 , < V2.50
(custom)
|
|
| Siemens | SICAM TM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICORE Base system |
Affected:
0 , < V2.20.0
(custom)
|
|
| Siemens | SINEC INS |
Affected:
0 , < V1.0 SP2 Update 4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPROTEC 5 - CP200 Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD84 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 6MU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) V9.8x |
Affected:
0 , < V9.83
(custom)
|
|
| Siemens | SIPROTEC 5 7SX82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SY82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UM85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 Compact 7SX800 (CP050) |
Affected:
0 , < V10.0
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rfc",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T03:55:37.141738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-04T21:05:25.373Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:52.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
},
{
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"tags": [
"x_transferred"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.blastradius.fail/"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"url": "https://www.kb.cert.org/vuls/id/456537"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "CPC80 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.51",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CPCI85 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q200 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Powerlink IP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.22",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM CROSSBOW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600F",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600FNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000ANC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000H",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000HNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GPNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG907R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG908C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG909R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG910C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2428P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3 3G-Router (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X304-2FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X306-1LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1 FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1-2LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 SC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC316-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC416-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC424-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC432",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCH328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM324",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216PoE EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM AK 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM BC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge (Classic)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge Applications for SICAM 8 Platform",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridPass",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM TM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICORE Base system",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.20.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC INS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0 SP2 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 - CP200 Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T09:01:52.617Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "RFC",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"
}
],
"descriptions": [
{
"lang": "en",
"value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-328: Use of Weak Hash",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T17:29:16.788Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"url": "https://www.blastradius.fail/"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT for SIPROTEC, SICAM and related product",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.",
"x_generator": {
"engine": "VINCE 3.0.4",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-3596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-3596",
"datePublished": "2024-07-09T12:02:53.001Z",
"dateReserved": "2024-04-10T15:09:45.391Z",
"dateUpdated": "2026-06-09T09:01:52.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-39920 (GCVE-0-2024-39920)
Vulnerability from cvelistv5 – Published: 2024-07-03 00:00 – Updated: 2024-08-05 18:37
VLAI
EPSS
VEX
Summary
The TCP protocol in RFC 9293 has a timing side channel that makes it easier for remote attackers to infer the content of one TCP connection from a client system (to any server), when that client system is concurrently obtaining TCP data at a slow rate from an attacker-controlled server, aka the "SnailLoad" issue. For example, the attack can begin by measuring RTTs via the TCP segments whose role is to provide an ACK control bit and an Acknowledgment Number.
Severity
4.3 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-05 18:27 UTC
CWE
- n/a
- CWE-1255 - Comparison Logic is Vulnerable to Power Side-Channel Attacks
Assigner
References
8 references
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:10.876Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.snailload.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.snailload.com/snailload.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/IAIK/SnailLoad"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.rfc-editor.org/rfc/rfc9293.txt"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tugraz.at/en/tu-graz/services/news-stories/tu-graz-news/singleview/article/neue-sicherheitsluecke-erlaubt-ueberwachung-besuchter-websites-und-angesehener-videos"
},
{
"tags": [
"x_transferred"
],
"url": "https://twitter.com/tugraz/status/1805272833322299412"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40809629"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.instagram.com/p/C8wpO1UtExw/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:tcp:9293:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tcp",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "9293"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-39920",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T18:27:41.004792Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1255",
"description": "CWE-1255 Comparison Logic is Vulnerable to Power Side-Channel Attacks",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T18:37:40.784Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The TCP protocol in RFC 9293 has a timing side channel that makes it easier for remote attackers to infer the content of one TCP connection from a client system (to any server), when that client system is concurrently obtaining TCP data at a slow rate from an attacker-controlled server, aka the \"SnailLoad\" issue. For example, the attack can begin by measuring RTTs via the TCP segments whose role is to provide an ACK control bit and an Acknowledgment Number."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T04:08:03.460Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.snailload.com"
},
{
"url": "https://www.snailload.com/snailload.pdf"
},
{
"url": "https://github.com/IAIK/SnailLoad"
},
{
"url": "https://www.rfc-editor.org/rfc/rfc9293.txt"
},
{
"url": "https://www.tugraz.at/en/tu-graz/services/news-stories/tu-graz-news/singleview/article/neue-sicherheitsluecke-erlaubt-ueberwachung-besuchter-websites-und-angesehener-videos"
},
{
"url": "https://twitter.com/tugraz/status/1805272833322299412"
},
{
"url": "https://news.ycombinator.com/item?id=40809629"
},
{
"url": "https://www.instagram.com/p/C8wpO1UtExw/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-39920",
"datePublished": "2024-07-03T00:00:00.000Z",
"dateReserved": "2024-07-03T00:00:00.000Z",
"dateUpdated": "2024-08-05T18:37:40.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3661 (GCVE-0-2024-3661)
Vulnerability from cvelistv5 – Published: 2024-05-06 18:31 – Updated: 2024-08-28 19:09
VLAI
EPSS
VEX
Title
DHCP routing options can manipulate interface-based VPN traffic
Summary
DHCP can add routes to a client’s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-08 04:00 UTC
References
20 references
Date Public
2002-12-31 01:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:00.420Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2131#section-7"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc3442#section-7"
},
{
"tags": [
"x_transferred"
],
"url": "https://tunnelvisionbug.com/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.leviathansecurity.com/research/tunnelvision"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40279632"
},
{
"tags": [
"x_transferred"
],
"url": "https://arstechnica.com/security/2024/05/novel-attack-against-virtually-all-vpn-apps-neuters-their-entire-purpose/"
},
{
"tags": [
"x_transferred"
],
"url": "https://krebsonsecurity.com/2024/05/why-your-vpn-may-not-be-as-secure-as-it-claims/"
},
{
"tags": [
"x_transferred"
],
"url": "https://issuetracker.google.com/issues/263721377"
},
{
"tags": [
"x_transferred"
],
"url": "https://mullvad.net/en/blog/evaluating-the-impact-of-tunnelvision"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.zscaler.com/blogs/security-research/cve-2024-3661-k-tunnelvision-exposes-vpn-bypass-vulnerability"
},
{
"tags": [
"x_transferred"
],
"url": "https://lowendtalk.com/discussion/188857/a-rogue-dhcp-server-within-your-network-can-and-will-hijack-your-vpn-traffic"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=40284111"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.agwa.name/blog/post/hardening_openvpn_for_def_con"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.theregister.com/2024/05/07/vpn_tunnelvision_dhcp/"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.citrix.com/article/CTX677069/cloud-software-group-security-advisory-for-cve20243661"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2024-00009"
},
{
"tags": [
"x_transferred"
],
"url": "https://bst.cisco.com/quickview/bug/CSCwk05814"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2024-3661"
},
{
"tags": [
"x_transferred"
],
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-170"
},
{
"tags": [
"x_transferred"
],
"url": "https://my.f5.com/manage/s/article/K000139553"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3661",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T04:00:07.962328Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T19:09:06.995Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "DHCP",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "0"
}
]
}
],
"datePublic": "2002-12-31T01:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "DHCP can add routes to a client\u2019s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN."
}
],
"value": "DHCP can add routes to a client\u2019s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-501",
"description": "CWE-501 Trust Boundary Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-01T15:04:50.790Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2131#section-7"
},
{
"url": "https://datatracker.ietf.org/doc/html/rfc3442#section-7"
},
{
"url": "https://tunnelvisionbug.com/"
},
{
"url": "https://www.leviathansecurity.com/research/tunnelvision"
},
{
"url": "https://news.ycombinator.com/item?id=40279632"
},
{
"url": "https://arstechnica.com/security/2024/05/novel-attack-against-virtually-all-vpn-apps-neuters-their-entire-purpose/"
},
{
"url": "https://krebsonsecurity.com/2024/05/why-your-vpn-may-not-be-as-secure-as-it-claims/"
},
{
"url": "https://issuetracker.google.com/issues/263721377"
},
{
"url": "https://mullvad.net/en/blog/evaluating-the-impact-of-tunnelvision"
},
{
"url": "https://www.zscaler.com/blogs/security-research/cve-2024-3661-k-tunnelvision-exposes-vpn-bypass-vulnerability"
},
{
"url": "https://lowendtalk.com/discussion/188857/a-rogue-dhcp-server-within-your-network-can-and-will-hijack-your-vpn-traffic"
},
{
"url": "https://news.ycombinator.com/item?id=40284111"
},
{
"url": "https://www.agwa.name/blog/post/hardening_openvpn_for_def_con"
},
{
"url": "https://www.theregister.com/2024/05/07/vpn_tunnelvision_dhcp/"
},
{
"url": "https://support.citrix.com/article/CTX677069/cloud-software-group-security-advisory-for-cve20243661"
},
{
"url": "https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2024-00009"
},
{
"url": "https://bst.cisco.com/quickview/bug/CSCwk05814"
},
{
"url": "https://security.paloaltonetworks.com/CVE-2024-3661"
},
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-170"
},
{
"url": "https://my.f5.com/manage/s/article/K000139553"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DHCP routing options can manipulate interface-based VPN traffic",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2024-3661",
"datePublished": "2024-05-06T18:31:21.217Z",
"dateReserved": "2024-04-11T17:24:22.637Z",
"dateUpdated": "2024-08-28T19:09:06.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44487 (GCVE-0-2023-44487)
Vulnerability from cvelistv5 – Published: 2023-10-10 00:00 – Updated: 2026-07-14 12:03Summary
The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.
Severity
7.5 (High)
SSVC
Exploitation: active
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 20:34 UTC
CWE
- n/a
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
173 references
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| ietf | http |
Affected:
2.0
cpe:2.3:a:ietf:http:2.0:*:*:*:*:*:*:* |
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SINEC NMS |
Affected:
0 , < V3.0
(custom)
|
|
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:http:2.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "http",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-44487",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T20:34:21.334116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2023-10-10",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-44487"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:05:35.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-44487"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-10-10T00:00:00.000Z",
"value": "CVE-2023-44487 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T21:08:27.383Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/dotnet/core/blob/e4613450ea0da7fd2fc6b61dfb2c1c1dec1ce9ec/release-notes/6.0/6.0.23/6.0.23.md?plain=1#L73"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.cloudflare.com/technical-breakdown-http2-rapid-reset-ddos-attack/"
},
{
"tags": [
"x_transferred"
],
"url": "https://aws.amazon.com/security/security-bulletins/AWS-2023-011/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cloud.google.com/blog/products/identity-security/how-it-works-the-novel-http2-rapid-reset-ddos-attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.nginx.com/blog/http-2-rapid-reset-attack-impacting-f5-nginx-products/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cloud.google.com/blog/products/identity-security/google-cloud-mitigated-largest-ddos-attack-peaking-above-398-million-rps/"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37831062"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.cloudflare.com/zero-day-rapid-reset-http2-record-breaking-ddos-attack/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.phoronix.com/news/HTTP2-Rapid-Reset-Attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/envoyproxy/envoy/pull/30055"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/haproxy/haproxy/issues/2312"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/eclipse/jetty.project/issues/10679"
},
{
"tags": [
"x_transferred"
],
"url": "https://forums.swift.org/t/swift-nio-http2-security-update-cve-2023-44487-http-2-dos/67764"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nghttp2/nghttp2/pull/1961"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/netty/netty/commit/58f75f665aa81a8cbcf6ffa74820042a285c5e61"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/alibaba/tengine/issues/1872"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/tomcat/tree/main/java/org/apache/coyote/http2"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37830987"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37830998"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/caddyserver/caddy/issues/5877"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.bleepingcomputer.com/news/security/new-http-2-rapid-reset-zero-day-attack-breaks-ddos-records/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/bcdannyboy/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/grpc/grpc-go/pull/6703"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/icing/mod_h2/blob/0a864782af0a942aa2ad4ed960a6b32cd35bcf0a/mod_http2/README.md?plain=1#L239-L244"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nghttp2/nghttp2/releases/tag/v1.57.0"
},
{
"tags": [
"x_transferred"
],
"url": "https://mailman.nginx.org/pipermail/nginx-devel/2023-October/S36Q5HBXR7CAIMPLLPRSSSYR4PCMWILK.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://my.f5.com/manage/s/article/K000137106"
},
{
"tags": [
"x_transferred"
],
"url": "https://msrc.microsoft.com/blog/2023/10/microsoft-response-to-distributed-denial-of-service-ddos-attacks-against-http/2/"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.proxmox.com/show_bug.cgi?id=4988"
},
{
"tags": [
"x_transferred"
],
"url": "https://cgit.freebsd.org/ports/commit/?id=c64c329c2c1752f46b73e3e6ce9f4329be6629f9"
},
{
"tags": [
"x_transferred"
],
"url": "https://seanmonstar.com/post/730794151136935936/hyper-http2-rapid-reset-unaffected"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/microsoft/CBL-Mariner/pull/6381"
},
{
"tags": [
"x_transferred"
],
"url": "https://groups.google.com/g/golang-announce/c/iNNxDTCjZvo"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/facebook/proxygen/pull/466"
},
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/adulau/7c2bfb8e9cdbe4b35a5e131c66a0c088"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/micrictor/http2-rst-stream"
},
{
"tags": [
"x_transferred"
],
"url": "https://edg.io/lp/blog/resets-leaks-ddos-and-the-tale-of-a-hidden-cve"
},
{
"tags": [
"x_transferred"
],
"url": "https://openssf.org/blog/2023/10/10/http-2-rapid-reset-vulnerability-highlights-need-for-rapid-response/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/h2o/h2o/security/advisories/GHSA-2m7v-gc89-fjqf"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/h2o/h2o/pull/3291"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nodejs/node/pull/50121"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/dotnet/announcements/issues/277"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/golang/go/issues/63417"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-vx74-f528-fxqg"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/trafficserver/pull/10564"
},
{
"tags": [
"x_transferred"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://tomcat.apache.org/security-10.html#Fixed_in_Apache_Tomcat_10.1.14"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.apache.org/thread/5py8h42mxfsn8l1wy6o41xwhsjlsd87q"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.haproxy.com/blog/haproxy-is-not-affected-by-the-http-2-rapid-reset-attack-cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/opensearch-project/data-prepper/issues/3474"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kubernetes/kubernetes/pull/121120"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/oqtane/oqtane.framework/discussions/3367"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-xpw8-rcwv-8f8p"
},
{
"tags": [
"x_transferred"
],
"url": "https://netty.io/news/2023/10/10/4-1-100-Final.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/10/10/http2-rapid-reset-vulnerability-cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.theregister.com/2023/10/10/http2_rapid_reset_zeroday/"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.qualys.com/vulnerabilities-threat-research/2023/10/10/cve-2023-44487-http-2-rapid-reset-attack"
},
{
"tags": [
"x_transferred"
],
"url": "https://news.ycombinator.com/item?id=37837043"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kazu-yamamoto/http2/issues/93"
},
{
"tags": [
"x_transferred"
],
"url": "https://martinthomson.github.io/h2-stream-limits/draft-thomson-httpbis-h2-stream-limits.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kazu-yamamoto/http2/commit/f61d41a502bd0f60eb24e1ce14edc7b6df6722a1"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/httpd/blob/afcdbeebbff4b0c50ea26cdd16e178c0d1f24152/modules/http2/h2_mplx.c#L1101-L1113"
},
{
"name": "DSA-5522",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5522"
},
{
"name": "DSA-5521",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5521"
},
{
"tags": [
"x_transferred"
],
"url": "https://access.redhat.com/security/cve/cve-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/ninenines/cowboy/issues/1615"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/varnishcache/varnish-cache/issues/3996"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/tempesta-tech/tempesta/issues/1986"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.vespa.ai/cve-2023-44487/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/etcd-io/etcd/issues/16740"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.darkreading.com/cloud/internet-wide-zero-day-bug-fuels-largest-ever-ddos-event"
},
{
"tags": [
"x_transferred"
],
"url": "https://istio.io/latest/news/security/istio-security-2023-004/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/junkurihara/rust-rpxy/issues/97"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1216123"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2242803"
},
{
"tags": [
"x_transferred"
],
"url": "https://ubuntu.com/security/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://community.traefik.io/t/is-traefik-vulnerable-to-cve-2023-44487/20125"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/advisories/GHSA-qppj-fm5r-hxr3"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/httpd-site/pull/10"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/projectcontour/contour/pull/5826"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/linkerd/website/pull/1695/commits/4b9c6836471bc8270ab48aae6fd2181bc73fd632"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/line/armeria/pull/5232"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.litespeedtech.com/2023/10/11/rapid-reset-http-2-vulnerablilty/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/akka/akka-http/issues/4323"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/openresty/openresty/issues/930"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/apache/apisix/issues/10320"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Azure/AKS/issues/3947"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Kong/kong/discussions/11741"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/arkrwn/PoC/tree/main/CVE-2023-44487"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.netlify.com/blog/netlify-successfully-mitigates-cve-2023-44487/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/caddyserver/caddy/releases/tag/v2.7.5"
},
{
"name": "[debian-lts-announce] 20231013 [SECURITY] [DLA 3617-1] tomcat9 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00020.html"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/4"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/9"
},
{
"tags": [
"x_transferred"
],
"url": "https://arstechnica.com/security/2023/10/how-ddosers-used-the-http-2-protocol-to-deliver-attacks-of-unprecedented-size/"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.w3.org/Archives/Public/ietf-http-wg/2023OctDec/0025.html"
},
{
"name": "FEDORA-2023-ed2642fd58",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JMEXY22BFG5Q64HQCM5CK2Q7KDKVV4TY/"
},
{
"tags": [
"x_transferred"
],
"url": "https://linkerd.io/2023/10/12/linkerd-cve-2023-44487/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3621-1] nghttp2 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00023.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20231016-0001/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3617-2] tomcat9 regression update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00024.html"
},
{
"name": "[oss-security] 20231018 Vulnerability in Jenkins",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/4"
},
{
"name": "[oss-security] 20231018 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/8"
},
{
"name": "[oss-security] 20231019 CVE-2023-45802: Apache HTTP Server: HTTP/2 stream memory not reclaimed right away on RST",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/19/6"
},
{
"name": "FEDORA-2023-54fadada12",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZKQSIKIAT5TJ3WSLU3RDBQ35YX4GY4V3/"
},
{
"name": "FEDORA-2023-5ff7bf1dd8",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JIZSEFC3YKCGABA2BZW6ZJRMDZJMB7PJ/"
},
{
"name": "[oss-security] 20231020 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/20/8"
},
{
"name": "FEDORA-2023-17efd3f2cd",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WLPRQ5TWUQQXYWBJM7ECYDAIL2YVKIUH/"
},
{
"name": "FEDORA-2023-d5030c983c",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/E72T67UPDRXHIDLO3OROR25YAMN4GGW5/"
},
{
"name": "FEDORA-2023-0259c3f26f",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BFQD3KUEMFBHPAPBGLWQC34L4OWL5HAZ/"
},
{
"name": "FEDORA-2023-2a9214af5f",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZLU6U2R2IC2K64NDPNMV55AUAO65MAF4/"
},
{
"name": "FEDORA-2023-e9c04d81c1",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X6QXN4ORIVF6XBW4WWFE7VNPVC74S45Y/"
},
{
"name": "FEDORA-2023-f66fc0f62a",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LKYHSZQFDNR7RSA7LHVLLIAQMVYCUGBG/"
},
{
"name": "FEDORA-2023-4d2fd884ea",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/FNA62Q767CFAFHBCDKYNPBMZWB7TWYVU/"
},
{
"name": "FEDORA-2023-b2c50535cb",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LNMZJCDHGLJJLXO4OXWJMTVQRNWOC7UL/"
},
{
"name": "FEDORA-2023-fe53e13b5b",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/KSEGD2IWKNUO3DWY4KQGUQM5BISRWHQE/"
},
{
"name": "FEDORA-2023-4bf641255e",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CLB4TW7KALB3EEQWNWCN7OUIWWVWWCG2/"
},
{
"name": "[debian-lts-announce] 20231030 [SECURITY] [DLA 3641-1] jetty9 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00045.html"
},
{
"name": "DSA-5540",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5540"
},
{
"name": "[debian-lts-announce] 20231031 [SECURITY] [DLA 3638-1] h2o security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00047.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://discuss.hashicorp.com/t/hcsec-2023-32-vault-consul-and-boundary-affected-by-http-2-rapid-reset-denial-of-service-vulnerability-cve-2023-44487/59715"
},
{
"name": "FEDORA-2023-1caffb88af",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VHUHTSXLXGXS7JYKBXTA3VINUPHTNGVU/"
},
{
"name": "FEDORA-2023-3f70b8d406",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VSRDIV77HNKUSM7SJC5BKE5JSHLHU2NK/"
},
{
"name": "FEDORA-2023-7b52921cae",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3N4NJ7FR4X4FPZUGNTQAPSTVB2HB2Y4A/"
},
{
"name": "FEDORA-2023-7934802344",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ZB43REMKRQR62NJEI7I5NQ4FSXNLBKRT/"
},
{
"name": "FEDORA-2023-dbe64661af",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/HT7T2R4MQKLIF4ODV4BDLPARWFPCJ5CZ/"
},
{
"name": "FEDORA-2023-822aab0a5a",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/XFOIBB4YFICHDM7IBOP7PWXW3FX4HLL2/"
},
{
"name": "[debian-lts-announce] 20231105 [SECURITY] [DLA 3645-1] trafficserver security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00001.html"
},
{
"name": "DSA-5549",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5549"
},
{
"name": "FEDORA-2023-c0c6a91330",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2MBEPPC36UBVOZZNAXFHKLFGSLCMN5LI/"
},
{
"name": "FEDORA-2023-492b7be466",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WE2I52RHNNU42PX6NZ2RBUHSFFJ2LVZX/"
},
{
"name": "DSA-5558",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5558"
},
{
"name": "[debian-lts-announce] 20231119 [SECURITY] [DLA 3656-1] netty security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00012.html"
},
{
"name": "GLSA-202311-09",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202311-09"
},
{
"name": "DSA-5570",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5570"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240426-0007/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0007/"
},
{
"url": "https://www.vicarius.io/vsociety/posts/rapid-reset-cve-2023-44487-dos-in-http2-understanding-the-root-cause"
},
{
"url": "http://www.openwall.com/lists/oss-security/2025/08/13/6"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:03:17.389Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-832273.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-341067.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-082556.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T20:05:34.376Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/dotnet/core/blob/e4613450ea0da7fd2fc6b61dfb2c1c1dec1ce9ec/release-notes/6.0/6.0.23/6.0.23.md?plain=1#L73"
},
{
"url": "https://blog.cloudflare.com/technical-breakdown-http2-rapid-reset-ddos-attack/"
},
{
"url": "https://aws.amazon.com/security/security-bulletins/AWS-2023-011/"
},
{
"url": "https://cloud.google.com/blog/products/identity-security/how-it-works-the-novel-http2-rapid-reset-ddos-attack"
},
{
"url": "https://www.nginx.com/blog/http-2-rapid-reset-attack-impacting-f5-nginx-products/"
},
{
"url": "https://cloud.google.com/blog/products/identity-security/google-cloud-mitigated-largest-ddos-attack-peaking-above-398-million-rps/"
},
{
"url": "https://news.ycombinator.com/item?id=37831062"
},
{
"url": "https://blog.cloudflare.com/zero-day-rapid-reset-http2-record-breaking-ddos-attack/"
},
{
"url": "https://www.phoronix.com/news/HTTP2-Rapid-Reset-Attack"
},
{
"url": "https://github.com/envoyproxy/envoy/pull/30055"
},
{
"url": "https://github.com/haproxy/haproxy/issues/2312"
},
{
"url": "https://github.com/eclipse/jetty.project/issues/10679"
},
{
"url": "https://forums.swift.org/t/swift-nio-http2-security-update-cve-2023-44487-http-2-dos/67764"
},
{
"url": "https://github.com/nghttp2/nghttp2/pull/1961"
},
{
"url": "https://github.com/netty/netty/commit/58f75f665aa81a8cbcf6ffa74820042a285c5e61"
},
{
"url": "https://github.com/alibaba/tengine/issues/1872"
},
{
"url": "https://github.com/apache/tomcat/tree/main/java/org/apache/coyote/http2"
},
{
"url": "https://news.ycombinator.com/item?id=37830987"
},
{
"url": "https://news.ycombinator.com/item?id=37830998"
},
{
"url": "https://github.com/caddyserver/caddy/issues/5877"
},
{
"url": "https://www.bleepingcomputer.com/news/security/new-http-2-rapid-reset-zero-day-attack-breaks-ddos-records/"
},
{
"url": "https://github.com/bcdannyboy/CVE-2023-44487"
},
{
"url": "https://github.com/grpc/grpc-go/pull/6703"
},
{
"url": "https://github.com/icing/mod_h2/blob/0a864782af0a942aa2ad4ed960a6b32cd35bcf0a/mod_http2/README.md?plain=1#L239-L244"
},
{
"url": "https://github.com/nghttp2/nghttp2/releases/tag/v1.57.0"
},
{
"url": "https://mailman.nginx.org/pipermail/nginx-devel/2023-October/S36Q5HBXR7CAIMPLLPRSSSYR4PCMWILK.html"
},
{
"url": "https://my.f5.com/manage/s/article/K000137106"
},
{
"url": "https://msrc.microsoft.com/blog/2023/10/microsoft-response-to-distributed-denial-of-service-ddos-attacks-against-http/2/"
},
{
"url": "https://bugzilla.proxmox.com/show_bug.cgi?id=4988"
},
{
"url": "https://cgit.freebsd.org/ports/commit/?id=c64c329c2c1752f46b73e3e6ce9f4329be6629f9"
},
{
"name": "[oss-security] 20231010 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/10/7"
},
{
"name": "[oss-security] 20231010 CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"url": "https://seanmonstar.com/post/730794151136935936/hyper-http2-rapid-reset-unaffected"
},
{
"url": "https://github.com/microsoft/CBL-Mariner/pull/6381"
},
{
"url": "https://groups.google.com/g/golang-announce/c/iNNxDTCjZvo"
},
{
"url": "https://github.com/facebook/proxygen/pull/466"
},
{
"url": "https://gist.github.com/adulau/7c2bfb8e9cdbe4b35a5e131c66a0c088"
},
{
"url": "https://github.com/micrictor/http2-rst-stream"
},
{
"url": "https://edg.io/lp/blog/resets-leaks-ddos-and-the-tale-of-a-hidden-cve"
},
{
"url": "https://openssf.org/blog/2023/10/10/http-2-rapid-reset-vulnerability-highlights-need-for-rapid-response/"
},
{
"url": "https://github.com/h2o/h2o/security/advisories/GHSA-2m7v-gc89-fjqf"
},
{
"url": "https://github.com/h2o/h2o/pull/3291"
},
{
"url": "https://github.com/nodejs/node/pull/50121"
},
{
"url": "https://github.com/dotnet/announcements/issues/277"
},
{
"url": "https://github.com/golang/go/issues/63417"
},
{
"url": "https://github.com/advisories/GHSA-vx74-f528-fxqg"
},
{
"url": "https://github.com/apache/trafficserver/pull/10564"
},
{
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-44487"
},
{
"url": "https://tomcat.apache.org/security-10.html#Fixed_in_Apache_Tomcat_10.1.14"
},
{
"url": "https://lists.apache.org/thread/5py8h42mxfsn8l1wy6o41xwhsjlsd87q"
},
{
"url": "https://www.openwall.com/lists/oss-security/2023/10/10/6"
},
{
"url": "https://www.haproxy.com/blog/haproxy-is-not-affected-by-the-http-2-rapid-reset-attack-cve-2023-44487"
},
{
"url": "https://github.com/opensearch-project/data-prepper/issues/3474"
},
{
"url": "https://github.com/kubernetes/kubernetes/pull/121120"
},
{
"url": "https://github.com/oqtane/oqtane.framework/discussions/3367"
},
{
"url": "https://github.com/advisories/GHSA-xpw8-rcwv-8f8p"
},
{
"url": "https://netty.io/news/2023/10/10/4-1-100-Final.html"
},
{
"url": "https://www.cisa.gov/news-events/alerts/2023/10/10/http2-rapid-reset-vulnerability-cve-2023-44487"
},
{
"url": "https://www.theregister.com/2023/10/10/http2_rapid_reset_zeroday/"
},
{
"url": "https://blog.qualys.com/vulnerabilities-threat-research/2023/10/10/cve-2023-44487-http-2-rapid-reset-attack"
},
{
"url": "https://news.ycombinator.com/item?id=37837043"
},
{
"url": "https://github.com/kazu-yamamoto/http2/issues/93"
},
{
"url": "https://martinthomson.github.io/h2-stream-limits/draft-thomson-httpbis-h2-stream-limits.html"
},
{
"url": "https://github.com/kazu-yamamoto/http2/commit/f61d41a502bd0f60eb24e1ce14edc7b6df6722a1"
},
{
"url": "https://github.com/apache/httpd/blob/afcdbeebbff4b0c50ea26cdd16e178c0d1f24152/modules/http2/h2_mplx.c#L1101-L1113"
},
{
"name": "DSA-5522",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5522"
},
{
"name": "DSA-5521",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5521"
},
{
"url": "https://access.redhat.com/security/cve/cve-2023-44487"
},
{
"url": "https://github.com/ninenines/cowboy/issues/1615"
},
{
"url": "https://github.com/varnishcache/varnish-cache/issues/3996"
},
{
"url": "https://github.com/tempesta-tech/tempesta/issues/1986"
},
{
"url": "https://blog.vespa.ai/cve-2023-44487/"
},
{
"url": "https://github.com/etcd-io/etcd/issues/16740"
},
{
"url": "https://www.darkreading.com/cloud/internet-wide-zero-day-bug-fuels-largest-ever-ddos-event"
},
{
"url": "https://istio.io/latest/news/security/istio-security-2023-004/"
},
{
"url": "https://github.com/junkurihara/rust-rpxy/issues/97"
},
{
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1216123"
},
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2242803"
},
{
"url": "https://ubuntu.com/security/CVE-2023-44487"
},
{
"url": "https://community.traefik.io/t/is-traefik-vulnerable-to-cve-2023-44487/20125"
},
{
"url": "https://github.com/advisories/GHSA-qppj-fm5r-hxr3"
},
{
"url": "https://github.com/apache/httpd-site/pull/10"
},
{
"url": "https://github.com/projectcontour/contour/pull/5826"
},
{
"url": "https://github.com/linkerd/website/pull/1695/commits/4b9c6836471bc8270ab48aae6fd2181bc73fd632"
},
{
"url": "https://github.com/line/armeria/pull/5232"
},
{
"url": "https://blog.litespeedtech.com/2023/10/11/rapid-reset-http-2-vulnerablilty/"
},
{
"url": "https://security.paloaltonetworks.com/CVE-2023-44487"
},
{
"url": "https://github.com/akka/akka-http/issues/4323"
},
{
"url": "https://github.com/openresty/openresty/issues/930"
},
{
"url": "https://github.com/apache/apisix/issues/10320"
},
{
"url": "https://github.com/Azure/AKS/issues/3947"
},
{
"url": "https://github.com/Kong/kong/discussions/11741"
},
{
"url": "https://github.com/arkrwn/PoC/tree/main/CVE-2023-44487"
},
{
"url": "https://www.netlify.com/blog/netlify-successfully-mitigates-cve-2023-44487/"
},
{
"url": "https://github.com/caddyserver/caddy/releases/tag/v2.7.5"
},
{
"name": "[debian-lts-announce] 20231013 [SECURITY] [DLA 3617-1] tomcat9 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00020.html"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/4"
},
{
"name": "[oss-security] 20231013 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/13/9"
},
{
"url": "https://arstechnica.com/security/2023/10/how-ddosers-used-the-http-2-protocol-to-deliver-attacks-of-unprecedented-size/"
},
{
"url": "https://lists.w3.org/Archives/Public/ietf-http-wg/2023OctDec/0025.html"
},
{
"name": "FEDORA-2023-ed2642fd58",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/JMEXY22BFG5Q64HQCM5CK2Q7KDKVV4TY/"
},
{
"url": "https://linkerd.io/2023/10/12/linkerd-cve-2023-44487/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3621-1] nghttp2 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00023.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20231016-0001/"
},
{
"name": "[debian-lts-announce] 20231016 [SECURITY] [DLA 3617-2] tomcat9 regression update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00024.html"
},
{
"name": "[oss-security] 20231018 Vulnerability in Jenkins",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/4"
},
{
"name": "[oss-security] 20231018 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/18/8"
},
{
"name": "[oss-security] 20231019 CVE-2023-45802: Apache HTTP Server: HTTP/2 stream memory not reclaimed right away on RST",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/19/6"
},
{
"name": "FEDORA-2023-54fadada12",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZKQSIKIAT5TJ3WSLU3RDBQ35YX4GY4V3/"
},
{
"name": "FEDORA-2023-5ff7bf1dd8",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/JIZSEFC3YKCGABA2BZW6ZJRMDZJMB7PJ/"
},
{
"name": "[oss-security] 20231020 Re: CVE-2023-44487: HTTP/2 Rapid Reset attack against many implementations",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/10/20/8"
},
{
"name": "FEDORA-2023-17efd3f2cd",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WLPRQ5TWUQQXYWBJM7ECYDAIL2YVKIUH/"
},
{
"name": "FEDORA-2023-d5030c983c",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/E72T67UPDRXHIDLO3OROR25YAMN4GGW5/"
},
{
"name": "FEDORA-2023-0259c3f26f",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/BFQD3KUEMFBHPAPBGLWQC34L4OWL5HAZ/"
},
{
"name": "FEDORA-2023-2a9214af5f",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZLU6U2R2IC2K64NDPNMV55AUAO65MAF4/"
},
{
"name": "FEDORA-2023-e9c04d81c1",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/X6QXN4ORIVF6XBW4WWFE7VNPVC74S45Y/"
},
{
"name": "FEDORA-2023-f66fc0f62a",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LKYHSZQFDNR7RSA7LHVLLIAQMVYCUGBG/"
},
{
"name": "FEDORA-2023-4d2fd884ea",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FNA62Q767CFAFHBCDKYNPBMZWB7TWYVU/"
},
{
"name": "FEDORA-2023-b2c50535cb",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LNMZJCDHGLJJLXO4OXWJMTVQRNWOC7UL/"
},
{
"name": "FEDORA-2023-fe53e13b5b",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/KSEGD2IWKNUO3DWY4KQGUQM5BISRWHQE/"
},
{
"name": "FEDORA-2023-4bf641255e",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/CLB4TW7KALB3EEQWNWCN7OUIWWVWWCG2/"
},
{
"name": "[debian-lts-announce] 20231030 [SECURITY] [DLA 3641-1] jetty9 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00045.html"
},
{
"name": "DSA-5540",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5540"
},
{
"name": "[debian-lts-announce] 20231031 [SECURITY] [DLA 3638-1] h2o security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00047.html"
},
{
"url": "https://discuss.hashicorp.com/t/hcsec-2023-32-vault-consul-and-boundary-affected-by-http-2-rapid-reset-denial-of-service-vulnerability-cve-2023-44487/59715"
},
{
"name": "FEDORA-2023-1caffb88af",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VHUHTSXLXGXS7JYKBXTA3VINUPHTNGVU/"
},
{
"name": "FEDORA-2023-3f70b8d406",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VSRDIV77HNKUSM7SJC5BKE5JSHLHU2NK/"
},
{
"name": "FEDORA-2023-7b52921cae",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/3N4NJ7FR4X4FPZUGNTQAPSTVB2HB2Y4A/"
},
{
"name": "FEDORA-2023-7934802344",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ZB43REMKRQR62NJEI7I5NQ4FSXNLBKRT/"
},
{
"name": "FEDORA-2023-dbe64661af",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HT7T2R4MQKLIF4ODV4BDLPARWFPCJ5CZ/"
},
{
"name": "FEDORA-2023-822aab0a5a",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/XFOIBB4YFICHDM7IBOP7PWXW3FX4HLL2/"
},
{
"name": "[debian-lts-announce] 20231105 [SECURITY] [DLA 3645-1] trafficserver security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00001.html"
},
{
"name": "DSA-5549",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5549"
},
{
"name": "FEDORA-2023-c0c6a91330",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/2MBEPPC36UBVOZZNAXFHKLFGSLCMN5LI/"
},
{
"name": "FEDORA-2023-492b7be466",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WE2I52RHNNU42PX6NZ2RBUHSFFJ2LVZX/"
},
{
"name": "DSA-5558",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5558"
},
{
"name": "[debian-lts-announce] 20231119 [SECURITY] [DLA 3656-1] netty security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/11/msg00012.html"
},
{
"name": "GLSA-202311-09",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202311-09"
},
{
"name": "DSA-5570",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5570"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240426-0007/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0007/"
},
{
"url": "https://github.com/grpc/grpc/releases/tag/v1.59.2"
},
{
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-http2-reset-d8Kf32vZ"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-44487",
"datePublished": "2023-10-10T00:00:00.000Z",
"dateReserved": "2023-09-29T00:00:00.000Z",
"dateUpdated": "2026-07-14T12:03:17.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27862 (GCVE-0-2021-27862)
Vulnerability from cvelistv5 – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with an invalid length during Ethernet to Wifi frame translation
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers).
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:04 UTC
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| IEEE | 802.2 |
Affected:
802.2h-1997 , ≤ 802.2h-1997
(custom)
|
|
| IETF | draft-ietf-v6ops-ra-guard-08 |
Affected:
08 , ≤ 08
(custom)
|
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:28.789Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27862",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:04:33.466068Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:04:40.862Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard-08",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-130",
"description": "CWE-130 Improper Handling of Length Parameter",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with an invalid length during Ethernet to Wifi frame translation"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27862",
"datePublished": "2022-09-27T18:40:14.712Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:28.789Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27861 (GCVE-0-2021-27861)
Vulnerability from cvelistv5 – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with invalid lengths
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length (and optionally VLAN0 headers)
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:06 UTC
Assigner
References
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:27.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27861",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:06:05.203947Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:06:11.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length (and optionally VLAN0 headers)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-130",
"description": "CWE-130 Improper Handling of Length Parameter",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0 and LLC/SNAP headers with invalid lengths"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27861",
"datePublished": "2022-09-27T18:40:13.742Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:27.712Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27854 (GCVE-0-2021-27854)
Vulnerability from cvelistv5 – Published: 2022-09-27 18:40 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering bypass using stacked VLAN0, LLC/SNAP headers, and Ethernet to Wifi frame translation
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using combinations of VLAN 0 headers, LLC/SNAP headers, and converting frames from Ethernet to Wifi and its reverse.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:06 UTC
CWE
- CWE-290 - Authentication Bypass by Spoofing
Assigner
References
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:26.598Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27854",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:06:23.882465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:06:44.230Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using combinations of VLAN 0 headers, LLC/SNAP headers, and converting frames from Ethernet to Wifi and its reverse."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering bypass using stacked VLAN0, LLC/SNAP headers, and Ethernet to Wifi frame translation"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27854",
"datePublished": "2022-09-27T18:40:12.738Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:26.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-27853 (GCVE-0-2021-27853)
Vulnerability from cvelistv5 – Published: 2022-09-27 17:55 – Updated: 2025-11-04 19:12
VLAI
EPSS
VEX
Title
L2 network filtering can be bypassed using stacked VLAN0 and LLC/SNAP headers
Summary
Layer 2 network filtering capabilities such as IPv6 RA guard or ARP inspection can be bypassed using combinations of VLAN 0 headers and LLC/SNAP headers.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-21 15:26 UTC
CWE
- CWE-290 - Authentication Bypass by Spoofing
Assigner
References
7 references
Impacted products
Date Public
2022-09-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:25.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"tags": [
"x_transferred"
],
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"name": "20220927 Vulnerabilities in Layer 2 Network Security Controls Affecting Cisco Products: September 2022",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-VU855201-J3z8CKTX"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"tags": [
"x_transferred"
],
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
},
{
"url": "https://www.kb.cert.org/vuls/id/855201"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27853",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:26:49.324466Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:27:39.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "802.2",
"vendor": "IEEE",
"versions": [
{
"lessThanOrEqual": "802.2h-1997",
"status": "affected",
"version": "802.2h-1997",
"versionType": "custom"
}
]
},
{
"product": "draft-ietf-v6ops-ra-guard",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "08",
"status": "affected",
"version": "08",
"versionType": "custom"
}
]
},
{
"product": "P802.1Q",
"vendor": "IETF",
"versions": [
{
"lessThanOrEqual": "D1.0",
"status": "affected",
"version": "D1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Etienne Champetier (@champtar) \u003cchampetier.etienne@gmail.com\u003e"
}
],
"datePublic": "2022-09-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Layer 2 network filtering capabilities such as IPv6 RA guard or ARP inspection can be bypassed using combinations of VLAN 0 headers and LLC/SNAP headers."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-12T00:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08/"
},
{
"url": "https://standards.ieee.org/ieee/802.2/1048/"
},
{
"url": "https://standards.ieee.org/ieee/802.1Q/10323/"
},
{
"name": "20220927 Vulnerabilities in Layer 2 Network Security Controls Affecting Cisco Products: September 2022",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-VU855201-J3z8CKTX"
},
{
"url": "https://kb.cert.org/vuls/id/855201"
},
{
"url": "https://blog.champtar.fr/VLAN0_LLC_SNAP/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "L2 network filtering can be bypassed using stacked VLAN0 and LLC/SNAP headers"
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2021-27853",
"datePublished": "2022-09-27T17:55:09.203Z",
"dateReserved": "2021-03-01T00:00:00.000Z",
"dateUpdated": "2025-11-04T19:12:25.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-20949 (GCVE-0-2020-20949)
Vulnerability from cvelistv5 – Published: 2021-01-20 15:42 – Updated: 2026-07-09 00:09
VLAI
EPSS
VEX
Summary
Bleichenbacher's attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher's oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:09:53.140Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T15:47:56.997Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20949",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in STM32 cryptographic firmware library software expansion for STM32Cube (UM1924). The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf",
"refsource": "MISC",
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"name": "http://st.com",
"refsource": "MISC",
"url": "http://st.com"
},
{
"name": "http://x-cube-cryptolib.com",
"refsource": "MISC",
"url": "http://x-cube-cryptolib.com"
},
{
"name": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html",
"refsource": "MISC",
"url": "https://www.st.com/en/embedded-software/x-cube-cryptolib.html"
},
{
"name": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb",
"refsource": "MISC",
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20949",
"datePublished": "2021-01-20T15:42:18.000Z",
"dateReserved": "2020-08-13T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:09:53.140Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-20950 (GCVE-0-2020-20950)
Vulnerability from cvelistv5 – Published: 2021-01-19 12:22 – Updated: 2026-07-09 00:09
VLAI
EPSS
VEX
Summary
Bleichenbacher's attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher's oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:09:54.370Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-04T23:46:45.075Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20950",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Bleichenbacher\u0027s attack on PKCS #1 v1.5 padding for RSA in Microchip Libraries for Applications 2018-11-26 All up to 2018-11-26. The vulnerability can allow one to use Bleichenbacher\u0027s oracle attack to decrypt an encrypted ciphertext by making successive queries to the server using the vulnerable library, resulting in remote information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf",
"refsource": "MISC",
"url": "http://archiv.infsec.ethz.ch/education/fs08/secsem/bleichenbacher98.pdf"
},
{
"name": "http://microchip.com",
"refsource": "MISC",
"url": "http://microchip.com"
},
{
"name": "https://www.microchip.com/mplab/microchip-libraries-for-applications",
"refsource": "MISC",
"url": "https://www.microchip.com/mplab/microchip-libraries-for-applications"
},
{
"name": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb",
"refsource": "MISC",
"url": "https://bi-zone.medium.com/silence-will-fall-or-how-it-can-take-2-years-to-get-your-vuln-registered-e6134846f5bb"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20950",
"datePublished": "2021-01-19T12:22:55.000Z",
"dateReserved": "2020-08-13T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:09:54.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}