18 vulnerabilities found for SIPLUS LOGO! 12/24RCE by Siemens
CVE-2025-40817 (GCVE-0-2025-40817)
Vulnerability from nvd – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 14:38 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40817",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:38:33.137767Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:38:40.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:23.184Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40817",
"datePublished": "2025-11-11T20:20:42.082Z",
"dateReserved": "2025-04-16T08:50:26.975Z",
"dateUpdated": "2026-10-13T09:18:23.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40816 (GCVE-0-2025-40816)
Vulnerability from nvd – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 14:39 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40816",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:39:36.309629Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:39:43.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:21.945Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40816",
"datePublished": "2025-11-11T20:20:39.123Z",
"dateReserved": "2025-04-16T08:50:26.975Z",
"dateUpdated": "2026-10-13T09:18:21.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40815 (GCVE-0-2025-40815)
Vulnerability from nvd – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 18:25 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40815",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T18:25:57.878232Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T18:29:21.159Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:20.838Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40815",
"datePublished": "2025-11-11T20:20:37.904Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2026-10-13T09:18:20.838Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-39922 (GCVE-0-2024-39922)
Vulnerability from nvd – Published: 2024-08-13 07:54 – Updated: 2024-08-14 17:38
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-14 17:37 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39922",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T17:37:52.047490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T17:38:02.012Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:17.388Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-921449.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-39922",
"datePublished": "2024-08-13T07:54:17.388Z",
"dateReserved": "2024-07-03T07:46:36.220Z",
"dateUpdated": "2024-08-14T17:38:02.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42784 (GCVE-0-2022-42784)
Vulnerability from nvd – Published: 2023-12-12 10:02 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Severity
CWE
- CWE-1319 - Improper Protection against Electromagnetic Fault Injection (EM-FI)
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:04.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions \u003e= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions \u003e= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions \u003e= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1319",
"description": "CWE-1319: Improper Protection against Electromagnetic Fault Injection (EM-FI)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:57.161Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-844582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-42784",
"datePublished": "2023-12-12T10:02:37.510Z",
"dateReserved": "2022-10-11T11:45:41.037Z",
"dateUpdated": "2024-10-08T08:39:57.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36363 (GCVE-0-2022-36363)
Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.
Severity
CWE
- CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1285",
"description": "CWE-1285: Improper Validation of Specified Index, Position, or Offset in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:55.848Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36363",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:55.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36362 (GCVE-0-2022-36362)
Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
Severity
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
All versions
|
|
| Siemens | LOGO! 230RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 230RCEo |
Affected:
All versions
|
|
| Siemens | LOGO! 24CE |
Affected:
All versions
|
|
| Siemens | LOGO! 24CEo |
Affected:
All versions
|
|
| Siemens | LOGO! 24RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 24RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:54.573Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36362",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:54.573Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36361 (GCVE-0-2022-36361)
Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2024-11-20 14:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2023-12-18 17:33 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.331Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36361",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-18T17:33:51.777423Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T14:54:31.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:53.190Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36361",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-11-20T14:54:31.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25236 (GCVE-0-2020-25236)
Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device
executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
Severity
CWE
- CWE-755 - Improper Handling of Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device\nexecuting the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755: Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:39.411Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-783481.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-25236",
"datePublished": "2021-03-15T17:03:30.000Z",
"dateReserved": "2020-09-10T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40817 (GCVE-0-2025-40817)
Vulnerability from cvelistv5 – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 14:38 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40817",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:38:33.137767Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:38:40.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:23.184Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40817",
"datePublished": "2025-11-11T20:20:42.082Z",
"dateReserved": "2025-04-16T08:50:26.975Z",
"dateUpdated": "2026-10-13T09:18:23.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40816 (GCVE-0-2025-40816)
Vulnerability from cvelistv5 – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 14:39 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40816",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:39:36.309629Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:39:43.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:21.945Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40816",
"datePublished": "2025-11-11T20:20:39.123Z",
"dateReserved": "2025-04-16T08:50:26.975Z",
"dateUpdated": "2026-10-13T09:18:21.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40815 (GCVE-0-2025-40815)
Vulnerability from cvelistv5 – Published: 2025-11-11 20:20 – Updated: 2026-10-13 09:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-12 18:25 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < V1.84.05
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < V1.84.05
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40815",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T18:25:57.878232Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T18:29:21.159Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.84.05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T09:18:20.838Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40815",
"datePublished": "2025-11-11T20:20:37.904Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2026-10-13T09:18:20.838Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-39922 (GCVE-0-2024-39922)
Vulnerability from cvelistv5 – Published: 2024-08-13 07:54 – Updated: 2024-08-14 17:38
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-14 17:37 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39922",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T17:37:52.047490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T17:38:02.012Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:17.388Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-921449.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-39922",
"datePublished": "2024-08-13T07:54:17.388Z",
"dateReserved": "2024-07-03T07:46:36.220Z",
"dateUpdated": "2024-08-14T17:38:02.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42784 (GCVE-0-2022-42784)
Vulnerability from cvelistv5 – Published: 2023-12-12 10:02 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Severity
CWE
- CWE-1319 - Improper Protection against Electromagnetic Fault Injection (EM-FI)
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:04.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions \u003e= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions \u003e= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions \u003e= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1319",
"description": "CWE-1319: Improper Protection against Electromagnetic Fault Injection (EM-FI)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:57.161Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-844582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-42784",
"datePublished": "2023-12-12T10:02:37.510Z",
"dateReserved": "2022-10-11T11:45:41.037Z",
"dateUpdated": "2024-10-08T08:39:57.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36362 (GCVE-0-2022-36362)
Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
Severity
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
All versions
|
|
| Siemens | LOGO! 230RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 230RCEo |
Affected:
All versions
|
|
| Siemens | LOGO! 24CE |
Affected:
All versions
|
|
| Siemens | LOGO! 24CEo |
Affected:
All versions
|
|
| Siemens | LOGO! 24RCE |
Affected:
All versions
|
|
| Siemens | LOGO! 24RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
All versions
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:54.573Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36362",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:54.573Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36363 (GCVE-0-2022-36363)
Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.
Severity
CWE
- CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1285",
"description": "CWE-1285: Improper Validation of Specified Index, Position, or Offset in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:55.848Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36363",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:55.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36361 (GCVE-0-2022-36361)
Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2024-11-20 14:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2023-12-18 17:33 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.331Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36361",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-18T17:33:51.777423Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T14:54:31.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:53.190Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-955858.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36361",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-07-21T00:00:00.000Z",
"dateUpdated": "2024-11-20T14:54:31.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25236 (GCVE-0-2020-25236)
Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-10-08 08:39
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device
executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
Severity
CWE
- CWE-755 - Improper Handling of Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device\nexecuting the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755: Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:39.411Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-783481.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-25236",
"datePublished": "2021-03-15T17:03:30.000Z",
"dateReserved": "2020-09-10T00:00:00.000Z",
"dateUpdated": "2024-10-08T08:39:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}