CVE-2026-109619 (GCVE-0-2026-109619)
Vulnerability from nvd – Published: 2026-10-21 13:54 – Updated: 2026-11-16 15:18Title
RCE via stale global state
Summary
PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-21 00:00 UTC
CWE
Assigner
References
19 references
Impacted products
110 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109619",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:47.838Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109619 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-10-23T14:07:57.152Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:24.606Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:54:43.866Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via stale global state",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109619",
"datePublished": "2026-10-21T13:54:43.866Z",
"dateReserved": "2026-10-12T21:04:00.504Z",
"dateUpdated": "2026-11-16T15:18:24.606Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-109618 (GCVE-0-2026-109618)
Vulnerability from nvd – Published: 2026-10-21 13:48 – Updated: 2026-11-16 15:18Title
RCE via OOM corruption
Summary
PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-21 00:00 UTC
CWE
Assigner
References
12 references
Impacted products
109 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109618",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:46.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109618 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-11-15T00:15:58.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
},
{
"url": "http://seclists.org/fulldisclosure/2026/Oct/51"
},
{
"url": "https://github.com/rapid7/metasploit-framework/pull/22139"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:23.272Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "finder",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
}
],
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:48:34.845Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via OOM corruption",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109618",
"datePublished": "2026-10-21T13:48:34.845Z",
"dateReserved": "2026-10-12T21:03:58.117Z",
"dateUpdated": "2026-11-16T15:18:23.272Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-59693 (GCVE-0-2026-59693)
Vulnerability from nvd – Published: 2026-08-11 12:20 – Updated: 2026-08-11 18:08
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01.21.233.16-7862), Desigo PXC4 (All versions < V02.21.194.36-2715), Desigo PXC5.E003 (All versions < V02.21.194.36-2715), Desigo PXC5.E24 (All versions < V02.21.194.36-2715), Desigo PXC7 (All versions < V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-11 18:08 UTC
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
0 , < V01.21.233.16-7862
(custom)
|
|
| Siemens | Desigo PXC3 |
Affected:
0 , < V01.21.233.16-7862
(custom)
|
|
| Siemens | Desigo PXC4 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC5.E003 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC5.E24 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC7 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59693",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-11T18:08:48.569650Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T18:08:58.835Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V01.21.233.16-7862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V01.21.233.16-7862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5.E003",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5.E24",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.233.16-7862), Desigo PXC3 (All versions \u003c V01.21.233.16-7862), Desigo PXC4 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E003 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E24 (All versions \u003c V02.21.194.36-2715), Desigo PXC7 (All versions \u003c V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:20:26.209Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-781903.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-59693",
"datePublished": "2026-08-11T12:20:26.209Z",
"dateReserved": "2026-07-06T13:50:39.917Z",
"dateUpdated": "2026-08-11T18:08:58.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-24045 (GCVE-0-2022-24045)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as “Secure”, “HttpOnly”, or “SameSite”). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information.
Severity
No CVSS data available.
CWE
- CWE-614 - Sensitive Cookie in HTTPS Session Without 'Secure' Attribute
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.659Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as \u201cSecure\u201d, \u201cHttpOnly\u201d, or \u201cSameSite\u201d). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-614",
"description": "CWE-614: Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:35.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24045",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as \u201cSecure\u201d, \u201cHttpOnly\u201d, or \u201cSameSite\u201d). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-614: Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24045",
"datePublished": "2022-05-10T09:46:56.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.659Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24044 (GCVE-0-2022-24044)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account.
Severity
No CVSS data available.
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:34.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24044",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24044",
"datePublished": "2022-05-10T09:46:54.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24043 (GCVE-0-2022-24043)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames.
Severity
No CVSS data available.
CWE
- CWE-203 - Observable Discrepancy
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.653Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-203",
"description": "CWE-203: Observable Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:33.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24043",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-203: Observable Discrepancy"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24043",
"datePublished": "2022-05-10T09:46:53.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.653Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24042 (GCVE-0-2022-24042)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization.
Severity
No CVSS data available.
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613: Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:32.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24042",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613: Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24042",
"datePublished": "2022-05-10T09:46:51.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24041 (GCVE-0-2022-24041)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users.
Severity
No CVSS data available.
CWE
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.481Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-916",
"description": "CWE-916: Use of Password Hash With Insufficient Computational Effort",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:31.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24041",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-916: Use of Password Hash With Insufficient Computational Effort"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24041",
"datePublished": "2022-05-10T09:46:49.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.481Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24040 (GCVE-0-2022-24040)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account.
Severity
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:30.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24040",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24040",
"datePublished": "2022-05-10T09:46:48.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24039 (GCVE-0-2022-24039)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The “addCell” JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator’s workstation.
Severity
No CVSS data available.
CWE
- CWE-75 - Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.647Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The \u201caddCell\u201d JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator\u2019s workstation."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-75",
"description": "CWE-75: Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:29.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24039",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The \u201caddCell\u201d JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator\u2019s workstation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-75: Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24039",
"datePublished": "2022-05-10T09:46:46.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.647Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41545 (GCVE-0-2021-41545)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2024-08-04 03:15
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:15:28.250Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a \u201cout of work\u201d state and could result in the controller going into a \u201cfactory reset\u201d state."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T09:46:45.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-41545",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a \u201cout of work\u201d state and could result in the controller going into a \u201cfactory reset\u201d state."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-41545",
"datePublished": "2022-05-10T09:46:45.000Z",
"dateReserved": "2021-09-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T03:15:28.250Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-109619 (GCVE-0-2026-109619)
Vulnerability from cvelistv5 – Published: 2026-10-21 13:54 – Updated: 2026-11-16 15:18Title
RCE via stale global state
Summary
PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-21 00:00 UTC
CWE
Assigner
References
19 references
Impacted products
110 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109619",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:47.838Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109619 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-10-23T14:07:57.152Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:24.606Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:54:43.866Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via stale global state",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109619",
"datePublished": "2026-10-21T13:54:43.866Z",
"dateReserved": "2026-10-12T21:04:00.504Z",
"dateUpdated": "2026-11-16T15:18:24.606Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-109618 (GCVE-0-2026-109618)
Vulnerability from cvelistv5 – Published: 2026-10-21 13:48 – Updated: 2026-11-16 15:18Title
RCE via OOM corruption
Summary
PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-21 00:00 UTC
CWE
Assigner
References
12 references
Impacted products
109 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHP Group | PHP |
Affected:
8.2.* , < 8.2.35
(semver)
Affected: 8.3.* , < 8.3.36 (semver) Affected: 8.4.* , < 8.4.27 (semver) Affected: 8.5.* , < 8.5.12 (semver) |
|
| Siemens | AMIS TS |
Affected:
0 , < *
(custom)
|
|
| Siemens | AX4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX |
Affected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 360 NX3 M6 WM OD IISX - S |
Affected:
0 , < *
(custom)
|
|
| Siemens | Building X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | CADRA |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Call stations |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Capital |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Chargesight |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Cloud IC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Climatix Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect Insights |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X200 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X300 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Connect X500 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | cRSP |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Depotfinity |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Designcenter X Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR2 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo DXR3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo Optic |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC4 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC5 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo PXC7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | DFMExpress |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V2.0SP9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Engage V3.1SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Energy Management System |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted RTLS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Enlighted Space |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox H60 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Rapid |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Local Monitoring bt-monitoring-vm |
Affected:
0 , < V20261103
(custom)
|
|
| Siemens | Navigator E&S |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Novigo VANSYS core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PACE-Design |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Professional - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard - XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | PADS Standard & Standard Plus |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Pathway to Learning Engineering |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Polarion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | QuadView |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sicharge D Configuration Backend |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flomaster |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Flux |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Simcenter Simlab |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sinteso FS20 EN |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SiPass integrated |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPORT |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Control Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Intrusion |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Siveillance Video |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Solid Edge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power 7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Spectrum Power TG |
Affected:
0 , < *
(custom)
|
|
| Siemens | Supply Chain Suite |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Product Cost Management |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Share |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Teamcenter Visualization |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | TestWay |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Valor NPI |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Verischarge |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloudHeliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm panels |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Voice alarm systems and audio matrices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Workplace Experience |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | WTV676-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | WTV776-HB6035 Firmware |
Affected:
0 , < *
(custom)
|
|
| Siemens | Xcargo |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Designer |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Enterprise XCR |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition IC Packaging |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Xpedition Layout Browser |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-109618",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-10-26",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:46.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.wiz.io/blog/php2shell-php-rce"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://php2shell.delftintellab.com"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-26T00:00:00.000Z",
"value": "CVE-2026-109618 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-11-15T00:15:58.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
},
{
"url": "http://seclists.org/fulldisclosure/2026/Oct/51"
},
{
"url": "https://github.com/rapid7/metasploit-framework/pull/22139"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "AMIS TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "AX4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 360 NX3 M6 WM OD IISX - S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Building X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CADRA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Call stations",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Chargesight",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Cloud IC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Climatix Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect Insights",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X300",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Connect X500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "cRSP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Depotfinity",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter X Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo DXR3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo Optic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DFMExpress",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V2.0SP9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Engage V3.1SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Energy Management System",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted RTLS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Enlighted Space",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox H60",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Rapid",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Local Monitoring bt-monitoring-vm",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V20261103",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Navigator E\u0026S",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Novigo VANSYS core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PACE-Design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard - XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Standard \u0026 Standard Plus",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Pathway to Learning Engineering",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Polarion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "QuadView",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sicharge D Configuration Backend",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flomaster",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Flux",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Simlab",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sinteso FS20 EN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPORT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Intrusion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Video",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Spectrum Power TG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Supply Chain Suite",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Product Cost Management",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Share",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TestWay",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Valor NPI",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Verischarge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloudHeliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Voice alarm systems and audio matrices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Workplace Experience",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV676-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "WTV776-HB6035 Firmware",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xcargo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise XCR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition IC Packaging",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-16T15:18:23.272Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "php-src",
"product": "PHP",
"vendor": "PHP Group",
"versions": [
{
"lessThan": "8.2.35",
"status": "affected",
"version": "8.2.*",
"versionType": "semver"
},
{
"lessThan": "8.3.36",
"status": "affected",
"version": "8.3.*",
"versionType": "semver"
},
{
"lessThan": "8.4.27",
"status": "affected",
"version": "8.4.*",
"versionType": "semver"
},
{
"lessThan": "8.5.12",
"status": "affected",
"version": "8.5.*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ryan at Calif.io"
},
{
"lang": "en",
"type": "reporter",
"value": "Wiz"
},
{
"lang": "en",
"type": "finder",
"value": "OpenAI"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Arnaud Le Blanc"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Ilija Tovilo"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Jakub Zelenka"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Nora Dossche"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
}
],
"value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a privileged process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of uninitialized pointer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1325",
"description": "CWE-1325 Improperly controlled sequential memory allocation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1419",
"description": "CWE-1419 Incorrect Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T13:48:34.845Z",
"orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"shortName": "php"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via OOM corruption",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"value": "Check the GitHub Security Advisory for mitigation strategies."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
"assignerShortName": "php",
"cveId": "CVE-2026-109618",
"datePublished": "2026-10-21T13:48:34.845Z",
"dateReserved": "2026-10-12T21:03:58.117Z",
"dateUpdated": "2026-11-16T15:18:23.272Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-59693 (GCVE-0-2026-59693)
Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 18:08
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01.21.233.16-7862), Desigo PXC4 (All versions < V02.21.194.36-2715), Desigo PXC5.E003 (All versions < V02.21.194.36-2715), Desigo PXC5.E24 (All versions < V02.21.194.36-2715), Desigo PXC7 (All versions < V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-11 18:08 UTC
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
0 , < V01.21.233.16-7862
(custom)
|
|
| Siemens | Desigo PXC3 |
Affected:
0 , < V01.21.233.16-7862
(custom)
|
|
| Siemens | Desigo PXC4 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC5.E003 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC5.E24 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
|
| Siemens | Desigo PXC7 |
Affected:
0 , < V02.21.194.36-2715
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59693",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-11T18:08:48.569650Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T18:08:58.835Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V01.21.233.16-7862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V01.21.233.16-7862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5.E003",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC5.E24",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V02.21.194.36-2715",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.233.16-7862), Desigo PXC3 (All versions \u003c V01.21.233.16-7862), Desigo PXC4 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E003 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E24 (All versions \u003c V02.21.194.36-2715), Desigo PXC7 (All versions \u003c V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:20:26.209Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-781903.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-59693",
"datePublished": "2026-08-11T12:20:26.209Z",
"dateReserved": "2026-07-06T13:50:39.917Z",
"dateUpdated": "2026-08-11T18:08:58.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-24045 (GCVE-0-2022-24045)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as “Secure”, “HttpOnly”, or “SameSite”). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information.
Severity
No CVSS data available.
CWE
- CWE-614 - Sensitive Cookie in HTTPS Session Without 'Secure' Attribute
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.659Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as \u201cSecure\u201d, \u201cHttpOnly\u201d, or \u201cSameSite\u201d). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-614",
"description": "CWE-614: Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:35.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24045",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as \u201cSecure\u201d, \u201cHttpOnly\u201d, or \u201cSameSite\u201d). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-614: Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24045",
"datePublished": "2022-05-10T09:46:56.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.659Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24044 (GCVE-0-2022-24044)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account.
Severity
No CVSS data available.
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:34.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24044",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24044",
"datePublished": "2022-05-10T09:46:54.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24043 (GCVE-0-2022-24043)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames.
Severity
No CVSS data available.
CWE
- CWE-203 - Observable Discrepancy
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.653Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-203",
"description": "CWE-203: Observable Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:33.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24043",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The login functionality of the application fails to normalize the response times of login attempts performed with wrong usernames with the ones executed with correct usernames. A remote unauthenticated attacker could exploit this side-channel information to perform a username enumeration attack and identify valid usernames."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-203: Observable Discrepancy"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24043",
"datePublished": "2022-05-10T09:46:53.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.653Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24042 (GCVE-0-2022-24042)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization.
Severity
No CVSS data available.
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613: Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:32.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24042",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613: Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24042",
"datePublished": "2022-05-10T09:46:51.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24041 (GCVE-0-2022-24041)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users.
Severity
No CVSS data available.
CWE
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.481Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-916",
"description": "CWE-916: Use of Password Hash With Insufficient Computational Effort",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:31.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24041",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-916: Use of Password Hash With Insufficient Computational Effort"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24041",
"datePublished": "2022-05-10T09:46:49.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.481Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24040 (GCVE-0-2022-24040)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account.
Severity
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:30.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24040",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The web application fails to enforce an upper bound to the cost factor of the PBKDF2 derived key during the creation or update of an account. An attacker with the user profile access privilege could cause a denial of service (DoS) condition through CPU consumption by setting a PBKDF2 derived key with a remarkably high cost effort and then attempting a login to the so-modified account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24040",
"datePublished": "2022-05-10T09:46:48.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24039 (GCVE-0-2022-24039)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-03 03:59
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The “addCell” JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator’s workstation.
Severity
No CVSS data available.
CWE
- CWE-75 - Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:59:23.647Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The \u201caddCell\u201d JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator\u2019s workstation."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-75",
"description": "CWE-75: Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:21:29.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-24039",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). The \u201caddCell\u201d JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator\u2019s workstation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-75: Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-626968.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24039",
"datePublished": "2022-05-10T09:46:46.000Z",
"dateReserved": "2022-01-27T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:59:23.647Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41545 (GCVE-0-2021-41545)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2024-08-04 03:15
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo DXR2 |
Affected:
All versions < V01.21.142.5-22
|
|
| Siemens | Desigo PXC3 |
Affected:
All versions < V01.21.142.4-18
|
|
| Siemens | Desigo PXC4 |
Affected:
All versions < V02.20.142.10-10884
|
|
| Siemens | Desigo PXC5 |
Affected:
All versions < V02.20.142.10-10884
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:15:28.250Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desigo DXR2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.5-22"
}
]
},
{
"product": "Desigo PXC3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.21.142.4-18"
}
]
},
{
"product": "Desigo PXC4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
},
{
"product": "Desigo PXC5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V02.20.142.10-10884"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a \u201cout of work\u201d state and could result in the controller going into a \u201cfactory reset\u201d state."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T09:46:45.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-41545",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desigo DXR2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.5-22"
}
]
}
},
{
"product_name": "Desigo PXC3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V01.21.142.4-18"
}
]
}
},
{
"product_name": "Desigo PXC4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
},
{
"product_name": "Desigo PXC5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V02.20.142.10-10884"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.142.5-22), Desigo PXC3 (All versions \u003c V01.21.142.4-18), Desigo PXC4 (All versions \u003c V02.20.142.10-10884), Desigo PXC5 (All versions \u003c V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a \u201cout of work\u201d state and could result in the controller going into a \u201cfactory reset\u201d state."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-41545",
"datePublished": "2022-05-10T09:46:45.000Z",
"dateReserved": "2021-09-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T03:15:28.250Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",