Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for 800xa by abb

    CVE-2021-22277 (GCVE-0-2021-22277)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2024-09-17 01:41
    VLAI
    Title
    AC 800M MMS - Denial of Service vulnerability in MMS communication
    Summary
    Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
    CWE
    • CWE-20 - Improper Input Validation
    References
    Impacted products
    Vendor Product Version
    ABB 800xA, Control Software for AC 800M Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB Control Builder Safe Affected: 1.x
    Affected: 2.0
    Affected: 3.0
    Create a notification for this product.
    ABB Compact Product Suite - Control and I/O Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB ABB Base Software for SoftControl Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    Date Public
    2022-02-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:37:18.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA, Control Software for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Control Builder Safe",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.x"
                },
                {
                  "status": "affected",
                  "version": "2.0"
                },
                {
                  "status": "affected",
                  "version": "3.0"
                }
              ]
            },
            {
              "product": "Compact Product Suite - Control and I/O",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "ABB Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-02-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-01T22:17:43.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AC 800M MMS - Denial of Service vulnerability in MMS communication",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-02-17T10:33:00.000Z",
              "ID": "CVE-2021-22277",
              "STATE": "PUBLIC",
              "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA, Control Software for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder Safe",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.x"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "2.0"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "3.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Compact Product Suite - Control and I/O",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ABB Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22277",
        "datePublished": "2022-04-01T22:17:43.044Z",
        "dateReserved": "2021-01-05T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:41:41.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8485 (GCVE-0-2020-8485)

    Vulnerability from nvd – Published: 2020-04-29 01:59 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    References
    Impacted products
    Vendor Product Version
    ABB 800xA for MOD300 Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:46.099Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA for MOD300",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:59:04.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8485",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA for MOD300",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8485",
        "datePublished": "2020-04-29T01:59:04.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:46.099Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8484 (GCVE-0-2020-8484)

    Vulnerability from nvd – Published: 2020-04-29 01:58 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability - 800xA for DCI
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    References
    Impacted products
    Vendor Product Version
    ABB 800xA for DCI Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:45.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA for DCI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:58:57.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8484",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA for DCI",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8484",
        "datePublished": "2020-04-29T01:58:57.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22277 (GCVE-0-2021-22277)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2024-09-17 01:41
    VLAI
    Title
    AC 800M MMS - Denial of Service vulnerability in MMS communication
    Summary
    Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
    CWE
    • CWE-20 - Improper Input Validation
    References
    Impacted products
    Vendor Product Version
    ABB 800xA, Control Software for AC 800M Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB Control Builder Safe Affected: 1.x
    Affected: 2.0
    Affected: 3.0
    Create a notification for this product.
    ABB Compact Product Suite - Control and I/O Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB ABB Base Software for SoftControl Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    Date Public
    2022-02-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:37:18.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA, Control Software for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Control Builder Safe",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.x"
                },
                {
                  "status": "affected",
                  "version": "2.0"
                },
                {
                  "status": "affected",
                  "version": "3.0"
                }
              ]
            },
            {
              "product": "Compact Product Suite - Control and I/O",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "ABB Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-02-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-01T22:17:43.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AC 800M MMS - Denial of Service vulnerability in MMS communication",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-02-17T10:33:00.000Z",
              "ID": "CVE-2021-22277",
              "STATE": "PUBLIC",
              "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA, Control Software for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder Safe",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.x"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "2.0"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "3.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Compact Product Suite - Control and I/O",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ABB Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22277",
        "datePublished": "2022-04-01T22:17:43.044Z",
        "dateReserved": "2021-01-05T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:41:41.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8485 (GCVE-0-2020-8485)

    Vulnerability from cvelistv5 – Published: 2020-04-29 01:59 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    References
    Impacted products
    Vendor Product Version
    ABB 800xA for MOD300 Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:46.099Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA for MOD300",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:59:04.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8485",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA for MOD300",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8485",
        "datePublished": "2020-04-29T01:59:04.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:46.099Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8484 (GCVE-0-2020-8484)

    Vulnerability from cvelistv5 – Published: 2020-04-29 01:58 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability - 800xA for DCI
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    References
    Impacted products
    Vendor Product Version
    ABB 800xA for DCI Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:45.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA for DCI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:58:57.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8484",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA for DCI",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8484",
        "datePublished": "2020-04-29T01:58:57.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }