Search
Find a vulnerability
Search criteria
4 vulnerabilities found for wvc54gc by cisco
CVE-2009-1560 (GCVE-0-2009-1560)
Vulnerability from nvd – Published: 2009-05-06 16:00 – Updated: 2024-08-07 05:20
VLAI
EPSS
VEX
Summary
The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.vupen.com/english/advisories/2009/1173 | vdb-entryx_refsource_VUPEN |
| http://www.gnucitizen.org/blog/hacking-linksys-ip… | x_refsource_MISC |
Date Public
2009-04-25 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T05:20:34.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2009-04-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2009-1560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"name": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/",
"refsource": "MISC",
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2009-1560",
"datePublished": "2009-05-06T16:00:00.000Z",
"dateReserved": "2009-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-07T05:20:34.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4391 (GCVE-0-2008-4391)
Vulnerability from nvd – Published: 2008-12-09 00:00 – Updated: 2024-08-07 10:17
VLAI
EPSS
VEX
Summary
Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/639345 | third-party-advisoryx_refsource_CERT-VN |
| http://www.securityfocus.com/bid/32665 | vdb-entryx_refsource_BID |
| http://www.kb.cert.org/vuls/id/WDON-7M2U52 | x_refsource_CONFIRM |
| http://secunia.com/advisories/33032 | third-party-advisoryx_refsource_SECUNIA |
Date Public
2008-01-03 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:17:09.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/33032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2008-01-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2009-03-03T10:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/33032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2008-4391",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#639345",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/32665"
},
{
"name": "http://www.kb.cert.org/vuls/id/WDON-7M2U52",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/33032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2008-4391",
"datePublished": "2008-12-09T00:00:00.000Z",
"dateReserved": "2008-10-02T00:00:00.000Z",
"dateUpdated": "2024-08-07T10:17:09.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2009-1560 (GCVE-0-2009-1560)
Vulnerability from cvelistv5 – Published: 2009-05-06 16:00 – Updated: 2024-08-07 05:20
VLAI
EPSS
VEX
Summary
The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.vupen.com/english/advisories/2009/1173 | vdb-entryx_refsource_VUPEN |
| http://www.gnucitizen.org/blog/hacking-linksys-ip… | x_refsource_MISC |
Date Public
2009-04-25 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T05:20:34.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2009-04-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2009-1560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"name": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/",
"refsource": "MISC",
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2009-1560",
"datePublished": "2009-05-06T16:00:00.000Z",
"dateReserved": "2009-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-07T05:20:34.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4391 (GCVE-0-2008-4391)
Vulnerability from cvelistv5 – Published: 2008-12-09 00:00 – Updated: 2024-08-07 10:17
VLAI
EPSS
VEX
Summary
Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/639345 | third-party-advisoryx_refsource_CERT-VN |
| http://www.securityfocus.com/bid/32665 | vdb-entryx_refsource_BID |
| http://www.kb.cert.org/vuls/id/WDON-7M2U52 | x_refsource_CONFIRM |
| http://secunia.com/advisories/33032 | third-party-advisoryx_refsource_SECUNIA |
Date Public
2008-01-03 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:17:09.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/33032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2008-01-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2009-03-03T10:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/33032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2008-4391",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#639345",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/32665"
},
{
"name": "http://www.kb.cert.org/vuls/id/WDON-7M2U52",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/33032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2008-4391",
"datePublished": "2008-12-09T00:00:00.000Z",
"dateReserved": "2008-10-02T00:00:00.000Z",
"dateUpdated": "2024-08-07T10:17:09.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}