Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for msc800_firmware by sick

    CVE-2024-8751 (GCVE-0-2024-8751)

    Vulnerability from nvd – Published: 2024-09-12 21:38 – Updated: 2026-07-24 12:01
    VLAI
    Title
    CVE-2024-8751
    Summary
    A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-13 13:53 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    SICK AG MSC800 Affected: V1.0 , ≤ <=V4.25 (custom)
    Affected: S1.0 , ≤ <=S2.93.19 (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC200 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC280 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC300 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS100FT Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS200HW Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS300P Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MERCEM300Z Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser SAM800 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser SIPROCESS Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GMS800 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GMS800 FIDOR Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GM32 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser VICOTEC320 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCU ETH-Service and Modbus-TCP Module Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser FLPS Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MES1B B&B Converter Affected: all versions (custom)
    Create a notification for this product.
    sick msc800_firmware Affected: 1.0 , ≤ 4.25 (custom)
    Affected: 1.0 , ≤ s2.93.19 (custom)
        cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-09-12 21:33
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "msc800_firmware",
                "vendor": "sick",
                "versions": [
                  {
                    "lessThanOrEqual": "4.25",
                    "status": "affected",
                    "version": "1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "s2.93.19",
                    "status": "affected",
                    "version": "1.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8751",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-13T13:53:13.856056Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-13T14:02:19.375Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MSC800",
              "vendor": "SICK AG",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c=V4.25",
                  "status": "affected",
                  "version": "V1.0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "\u003c=S2.93.19",
                  "status": "affected",
                  "version": "S1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC200",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC280",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC300",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS100FT",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS200HW",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS300P",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MERCEM300Z",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "SAM800",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "SIPROCESS",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GMS800",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GMS800 FIDOR",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GM32",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "VICOTEC320",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCU ETH-Service and Modbus-TCP Module",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "FLPS",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MES1B B\u0026B Converter",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2024-09-12T21:33:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T12:01:28.194Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_SICK PSIRT Website"
              ],
              "url": "https://sick.com/psirt"
            },
            {
              "tags": [
                "x_SICK Operating Guidelines"
              ],
              "url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
            },
            {
              "tags": [
                "x_ICS-CERT recommended practices on Industrial Security"
              ],
              "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
            },
            {
              "tags": [
                "x_CVSS v3.1 Calculator"
              ],
              "url": "https://www.first.org/cvss/calculator/3.1"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.pdf"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.pdf"
            },
            {
              "tags": [
                "x_The canonical URL"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.json"
            },
            {
              "tags": [
                "x_The canonical URL"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.json"
            },
            {
              "tags": [
                "x_Endress+Hauser"
              ],
              "url": "https://www.endress.com"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26\n\n\u003cbr\u003e"
                }
              ],
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26"
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20.\n\n\u003cbr\u003e"
                }
              ],
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-12T21:36:00.000Z",
              "value": "1: Initial version"
            },
            {
              "lang": "en",
              "time": "2026-07-16T10:00:00.000Z",
              "value": "2: Added more products"
            }
          ],
          "title": "CVE-2024-8751",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eFor Endress+Hauser\u0026nbsp;MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026amp;B Converter:\u0026nbsp; Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices.\u003c/p\u003e"
                }
              ],
              "value": "For Endress+Hauser\u00a0MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026B Converter:\u00a0 Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2024-8751",
        "datePublished": "2024-09-12T21:38:37.516Z",
        "dateReserved": "2024-09-12T13:17:03.176Z",
        "dateUpdated": "2026-07-24T12:01:28.194Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-27577 (GCVE-0-2022-27577)

    Vulnerability from nvd – Published: 2022-04-11 19:37 – Updated: 2024-08-03 05:32
    VLAI
    Summary
    The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version.
    Severity
    No CVSS data available.
    CWE
    References
    URL Tags
    https://sick.com/psirt x_refsource_MISC
    Impacted products
    Vendor Product Version
    n/a SICK MSC800 Affected: All versions before 4.15
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.251Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sick.com/psirt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SICK MSC800",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions before 4.15"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-342",
                  "description": "CWE-342",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-11T19:37:47.000Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sick.com/psirt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@sick.de",
              "ID": "CVE-2022-27577",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICK MSC800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions before 4.15"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-342"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sick.com/psirt",
                  "refsource": "MISC",
                  "url": "https://sick.com/psirt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2022-27577",
        "datePublished": "2022-04-11T19:37:47.000Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:32:59.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-2075 (GCVE-0-2020-2075)

    Vulnerability from nvd – Published: 2020-08-31 17:09 – Updated: 2024-08-04 06:54
    VLAI
    Summary
    Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH.
    Severity
    No CVSS data available.
    CWE
    • CWE-703 - Improper Check or Handling of Exceptional Conditions
    References
    Impacted products
    Vendor Product Version
    n/a Bulkscan LMS111; Bulkscan LMS511; CLV62x – CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH Affected: All Versions < V1.04
    Affected: All Versions < V2.30
    Affected: All versions with Ethernet interface
    Affected: All ICR890-3 and ICR890-3.5 devices all versions
    Affected: All Versions < V2.0
    Affected: All Versions < V2.10
    Affected: All versions
    Affected: All Versions < V4.10
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T06:54:00.593Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c V1.04"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.30"
                },
                {
                  "status": "affected",
                  "version": "All versions with Ethernet interface"
                },
                {
                  "status": "affected",
                  "version": "All ICR890-3 and ICR890-3.5 devices all versions"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.0"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.10"
                },
                {
                  "status": "affected",
                  "version": "All versions"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V4.10"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-703",
                  "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-31T17:09:07.000Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@sick.de",
              "ID": "CVE-2020-2075",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c V1.04"
                              },
                              {
                                "version_value": "All Versions \u003c V2.30"
                              },
                              {
                                "version_value": "All versions with Ethernet interface"
                              },
                              {
                                "version_value": "All ICR890-3 and ICR890-3.5 devices all versions"
                              },
                              {
                                "version_value": "All Versions \u003c V2.0"
                              },
                              {
                                "version_value": "All Versions \u003c V2.10"
                              },
                              {
                                "version_value": "All versions"
                              },
                              {
                                "version_value": "All Versions \u003c V4.10"
                              },
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories",
                  "refsource": "MISC",
                  "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2020-2075",
        "datePublished": "2020-08-31T17:09:07.000Z",
        "dateReserved": "2019-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T06:54:00.593Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10979 (GCVE-0-2019-10979)

    Vulnerability from nvd – Published: 2019-07-01 20:05 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - USE OF HARD-CODED CREDENTIALS CWE-798
    References
    Impacted products
    Vendor Product Version
    SICK MSC800 Affected: all versions prior to Version 4.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.569Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "108924",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/108924"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MSC800",
              "vendor": "SICK",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions prior to Version 4.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "USE OF HARD-CODED CREDENTIALS CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-01T12:53:22.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "108924",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/108924"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2019-10979",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MSC800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "all versions prior to Version 4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SICK"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CREDENTIALS CWE-798"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "108924",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/108924"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
                },
                {
                  "name": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories",
                  "refsource": "CONFIRM",
                  "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2019-10979",
        "datePublished": "2019-07-01T20:05:10.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8751 (GCVE-0-2024-8751)

    Vulnerability from cvelistv5 – Published: 2024-09-12 21:38 – Updated: 2026-07-24 12:01
    VLAI
    Title
    CVE-2024-8751
    Summary
    A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-13 13:53 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    SICK AG MSC800 Affected: V1.0 , ≤ <=V4.25 (custom)
    Affected: S1.0 , ≤ <=S2.93.19 (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC200 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC280 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MARSIC300 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS100FT Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS200HW Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCS300P Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MERCEM300Z Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser SAM800 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser SIPROCESS Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GMS800 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GMS800 FIDOR Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser GM32 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser VICOTEC320 Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MCU ETH-Service and Modbus-TCP Module Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser FLPS Affected: all versions (custom)
    Create a notification for this product.
    Endress+Hauser MES1B B&B Converter Affected: all versions (custom)
    Create a notification for this product.
    sick msc800_firmware Affected: 1.0 , ≤ 4.25 (custom)
    Affected: 1.0 , ≤ s2.93.19 (custom)
        cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-09-12 21:33
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "msc800_firmware",
                "vendor": "sick",
                "versions": [
                  {
                    "lessThanOrEqual": "4.25",
                    "status": "affected",
                    "version": "1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "s2.93.19",
                    "status": "affected",
                    "version": "1.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8751",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-13T13:53:13.856056Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-13T14:02:19.375Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MSC800",
              "vendor": "SICK AG",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c=V4.25",
                  "status": "affected",
                  "version": "V1.0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "\u003c=S2.93.19",
                  "status": "affected",
                  "version": "S1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC200",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC280",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MARSIC300",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS100FT",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS200HW",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCS300P",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MERCEM300Z",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "SAM800",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "SIPROCESS",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GMS800",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GMS800 FIDOR",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "GM32",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "VICOTEC320",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MCU ETH-Service and Modbus-TCP Module",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "FLPS",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "affected",
              "product": "MES1B B\u0026B Converter",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2024-09-12T21:33:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T12:01:28.194Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_SICK PSIRT Website"
              ],
              "url": "https://sick.com/psirt"
            },
            {
              "tags": [
                "x_SICK Operating Guidelines"
              ],
              "url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
            },
            {
              "tags": [
                "x_ICS-CERT recommended practices on Industrial Security"
              ],
              "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
            },
            {
              "tags": [
                "x_CVSS v3.1 Calculator"
              ],
              "url": "https://www.first.org/cvss/calculator/3.1"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.pdf"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.pdf"
            },
            {
              "tags": [
                "x_The canonical URL"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.json"
            },
            {
              "tags": [
                "x_The canonical URL"
              ],
              "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.json"
            },
            {
              "tags": [
                "x_Endress+Hauser"
              ],
              "url": "https://www.endress.com"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26\n\n\u003cbr\u003e"
                }
              ],
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26"
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20.\n\n\u003cbr\u003e"
                }
              ],
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-12T21:36:00.000Z",
              "value": "1: Initial version"
            },
            {
              "lang": "en",
              "time": "2026-07-16T10:00:00.000Z",
              "value": "2: Added more products"
            }
          ],
          "title": "CVE-2024-8751",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eFor Endress+Hauser\u0026nbsp;MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026amp;B Converter:\u0026nbsp; Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices.\u003c/p\u003e"
                }
              ],
              "value": "For Endress+Hauser\u00a0MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026B Converter:\u00a0 Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2024-8751",
        "datePublished": "2024-09-12T21:38:37.516Z",
        "dateReserved": "2024-09-12T13:17:03.176Z",
        "dateUpdated": "2026-07-24T12:01:28.194Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-27577 (GCVE-0-2022-27577)

    Vulnerability from cvelistv5 – Published: 2022-04-11 19:37 – Updated: 2024-08-03 05:32
    VLAI
    Summary
    The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version.
    Severity
    No CVSS data available.
    CWE
    References
    URL Tags
    https://sick.com/psirt x_refsource_MISC
    Impacted products
    Vendor Product Version
    n/a SICK MSC800 Affected: All versions before 4.15
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.251Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sick.com/psirt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SICK MSC800",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions before 4.15"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-342",
                  "description": "CWE-342",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-11T19:37:47.000Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sick.com/psirt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@sick.de",
              "ID": "CVE-2022-27577",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICK MSC800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions before 4.15"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-342"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sick.com/psirt",
                  "refsource": "MISC",
                  "url": "https://sick.com/psirt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2022-27577",
        "datePublished": "2022-04-11T19:37:47.000Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:32:59.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-2075 (GCVE-0-2020-2075)

    Vulnerability from cvelistv5 – Published: 2020-08-31 17:09 – Updated: 2024-08-04 06:54
    VLAI
    Summary
    Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH.
    Severity
    No CVSS data available.
    CWE
    • CWE-703 - Improper Check or Handling of Exceptional Conditions
    References
    Impacted products
    Vendor Product Version
    n/a Bulkscan LMS111; Bulkscan LMS511; CLV62x – CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH Affected: All Versions < V1.04
    Affected: All Versions < V2.30
    Affected: All versions with Ethernet interface
    Affected: All ICR890-3 and ICR890-3.5 devices all versions
    Affected: All Versions < V2.0
    Affected: All Versions < V2.10
    Affected: All versions
    Affected: All Versions < V4.10
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T06:54:00.593Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c V1.04"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.30"
                },
                {
                  "status": "affected",
                  "version": "All versions with Ethernet interface"
                },
                {
                  "status": "affected",
                  "version": "All ICR890-3 and ICR890-3.5 devices all versions"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.0"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V2.10"
                },
                {
                  "status": "affected",
                  "version": "All versions"
                },
                {
                  "status": "affected",
                  "version": "All Versions \u003c V4.10"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-703",
                  "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-31T17:09:07.000Z",
            "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
            "shortName": "SICK AG"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@sick.de",
              "ID": "CVE-2020-2075",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c V1.04"
                              },
                              {
                                "version_value": "All Versions \u003c V2.30"
                              },
                              {
                                "version_value": "All versions with Ethernet interface"
                              },
                              {
                                "version_value": "All ICR890-3 and ICR890-3.5 devices all versions"
                              },
                              {
                                "version_value": "All Versions \u003c V2.0"
                              },
                              {
                                "version_value": "All Versions \u003c V2.10"
                              },
                              {
                                "version_value": "All versions"
                              },
                              {
                                "version_value": "All Versions \u003c V4.10"
                              },
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories",
                  "refsource": "MISC",
                  "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "assignerShortName": "SICK AG",
        "cveId": "CVE-2020-2075",
        "datePublished": "2020-08-31T17:09:07.000Z",
        "dateReserved": "2019-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T06:54:00.593Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10979 (GCVE-0-2019-10979)

    Vulnerability from cvelistv5 – Published: 2019-07-01 20:05 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - USE OF HARD-CODED CREDENTIALS CWE-798
    References
    Impacted products
    Vendor Product Version
    SICK MSC800 Affected: all versions prior to Version 4.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.569Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "108924",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/108924"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MSC800",
              "vendor": "SICK",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions prior to Version 4.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "USE OF HARD-CODED CREDENTIALS CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-01T12:53:22.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "108924",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/108924"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2019-10979",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MSC800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "all versions prior to Version 4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SICK"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CREDENTIALS CWE-798"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "108924",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/108924"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-04"
                },
                {
                  "name": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories",
                  "refsource": "CONFIRM",
                  "url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2019-10979",
        "datePublished": "2019-07-01T20:05:10.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }