Find a vulnerability
Search criteria
10 vulnerabilities found for ioLogik E1200 Series by Moxa
CVE-2026-129972 (GCVE-0-2026-129972)
Vulnerability from nvd – Published: 2026-11-20 06:53 – Updated: 2026-11-20 17:16- CWE-120 - Buffer Copy without Checking Size of Input
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 4.0
(custom)
cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-129972",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-20T17:16:12.723334Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T17:16:22.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "4.0",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.0",
"versionStartIncluding": "1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A buffer overflow vulnerability exists in the web management service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit insufficient bounds checking of specially crafted HTTP requests, potentially causing the web management service to crash and resulting in a denial-of-service condition."
}
],
"value": "A buffer overflow vulnerability exists in the web management service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit insufficient bounds checking of specially crafted HTTP requests, potentially causing the web management service to crash and resulting in a denial-of-service condition."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100: Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T06:53:10.985Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please refer to the security advisory:\u003cdiv\u003ehttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os\u003c/div\u003e"
}
],
"value": "Please refer to the security advisory:https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-129972",
"datePublished": "2026-11-20T06:53:10.985Z",
"dateReserved": "2026-11-16T15:34:27.869Z",
"dateUpdated": "2026-11-20T17:16:22.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-129971 (GCVE-0-2026-129971)
Vulnerability from nvd – Published: 2026-11-20 06:51 – Updated: 2026-11-20 17:16- CWE-120 - Buffer Copy without Checking Size of Input
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 4.0
(custom)
cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-129971",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-20T17:16:40.536903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T17:16:53.518Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "4.0",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.0",
"versionStartIncluding": "1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A buffer overflow vulnerability exists in the SNMP service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit improper handling of specially crafted SNMP requests, potentially leading to a denial-of-service condition on the affected device."
}
],
"value": "A buffer overflow vulnerability exists in the SNMP service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit improper handling of specially crafted SNMP requests, potentially leading to a denial-of-service condition on the affected device."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100: Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T06:51:04.716Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please refer to the security advisory:\u0026nbsp;\u003cdiv\u003ehttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os\u0026nbsp;\u003c/div\u003e"
}
],
"value": "Please refer to the security advisory:\u00a0https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-129971",
"datePublished": "2026-11-20T06:51:04.716Z",
"dateReserved": "2026-11-16T15:34:26.051Z",
"dateUpdated": "2026-11-20T17:16:53.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-5962 (GCVE-0-2023-5962)
Vulnerability from nvd – Published: 2023-12-23 09:09 – Updated: 2024-10-28 06:14- CWE-328 - Use of Weak Hash
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 3.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.146Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "3.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reza Rashidi from HADESS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA weak cryptographic algorithm vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. This vulnerability can help an attacker compromise the confidentiality of sensitive data. This vulnerability may lead an attacker to get unexpected authorization.\u003c/p\u003e"
}
],
"value": "A weak cryptographic algorithm vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. This vulnerability can help an attacker compromise the confidentiality of sensitive data. This vulnerability may lead an attacker to get unexpected authorization."
}
],
"impacts": [
{
"capecId": "CAPEC-20",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-20: Encryption Brute Forcing"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-328",
"description": "CWE-328: Use of Weak Hash",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T06:14:46.184Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eioLogik E1200 Series : Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v3.3.7).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \n\n\n\n * ioLogik E1200 Series : Please contact Moxa Technical Support for the security patch (v3.3.7). https://www.moxa.com/tw/support/technical-support"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "ioLogik E1200 Series: Weak Cryptographic Algorithm Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-5962",
"datePublished": "2023-12-23T09:09:01.920Z",
"dateReserved": "2023-11-06T07:47:33.243Z",
"dateUpdated": "2024-10-28T06:14:46.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5961 (GCVE-0-2023-5961)
Vulnerability from nvd – Published: 2023-12-23 09:01 – Updated: 2024-11-27 18:28- CWE-352 - Cross-Site Request Forgery (CSRF)
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 3.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.125Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5961",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T18:28:26.021021Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T18:28:44.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "3.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reza Rashidi from HADESS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA Cross-Site Request Forgery (CSRF) vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. An attacker can exploit this vulnerability to trick a client into making an unintentional request to the web server, which will be treated as an authentic request. This vulnerability may lead an attacker to perform operations on behalf of the victimized user.\u003c/p\u003e"
}
],
"value": "A Cross-Site Request Forgery (CSRF) vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. An attacker can exploit this vulnerability to trick a client into making an unintentional request to the web server, which will be treated as an authentic request. This vulnerability may lead an attacker to perform operations on behalf of the victimized user.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-62",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-62: Cross Site Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-23T09:01:02.875Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \u003c/p\u003e\u003cul\u003e\u003cli\u003eioLogik E1200 Series : Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v3.3.7).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \n\n * ioLogik E1200 Series : Please contact Moxa Technical Support for the security patch (v3.3.7). https://www.moxa.com/tw/support/technical-support \n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "ioLogik E1200 Series: Cross-Site Request Forgery (CSRF) Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-5961",
"datePublished": "2023-12-23T09:01:02.875Z",
"dateReserved": "2023-11-06T07:47:31.237Z",
"dateUpdated": "2024-11-27T18:28:44.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-129972 (GCVE-0-2026-129972)
Vulnerability from cvelistv5 – Published: 2026-11-20 06:53 – Updated: 2026-11-20 17:16- CWE-120 - Buffer Copy without Checking Size of Input
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 4.0
(custom)
cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-129972",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-20T17:16:12.723334Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T17:16:22.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "4.0",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.0",
"versionStartIncluding": "1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A buffer overflow vulnerability exists in the web management service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit insufficient bounds checking of specially crafted HTTP requests, potentially causing the web management service to crash and resulting in a denial-of-service condition."
}
],
"value": "A buffer overflow vulnerability exists in the web management service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit insufficient bounds checking of specially crafted HTTP requests, potentially causing the web management service to crash and resulting in a denial-of-service condition."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100: Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T06:53:10.985Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please refer to the security advisory:\u003cdiv\u003ehttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os\u003c/div\u003e"
}
],
"value": "Please refer to the security advisory:https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-129972",
"datePublished": "2026-11-20T06:53:10.985Z",
"dateReserved": "2026-11-16T15:34:27.869Z",
"dateUpdated": "2026-11-20T17:16:22.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-129971 (GCVE-0-2026-129971)
Vulnerability from cvelistv5 – Published: 2026-11-20 06:51 – Updated: 2026-11-20 17:16- CWE-120 - Buffer Copy without Checking Size of Input
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 4.0
(custom)
cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-129971",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-20T17:16:40.536903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T17:16:53.518Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "4.0",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:iologik_e1200_series:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.0",
"versionStartIncluding": "1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A buffer overflow vulnerability exists in the SNMP service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit improper handling of specially crafted SNMP requests, potentially leading to a denial-of-service condition on the affected device."
}
],
"value": "A buffer overflow vulnerability exists in the SNMP service of the Ethernet Remote I/Os products. An unauthenticated remote attacker could exploit improper handling of specially crafted SNMP requests, potentially leading to a denial-of-service condition on the affected device."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100: Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-20T06:51:04.716Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please refer to the security advisory:\u0026nbsp;\u003cdiv\u003ehttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os\u0026nbsp;\u003c/div\u003e"
}
],
"value": "Please refer to the security advisory:\u00a0https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-129971",
"datePublished": "2026-11-20T06:51:04.716Z",
"dateReserved": "2026-11-16T15:34:26.051Z",
"dateUpdated": "2026-11-20T17:16:53.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-5962 (GCVE-0-2023-5962)
Vulnerability from cvelistv5 – Published: 2023-12-23 09:09 – Updated: 2024-10-28 06:14- CWE-328 - Use of Weak Hash
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 3.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.146Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "3.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reza Rashidi from HADESS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA weak cryptographic algorithm vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. This vulnerability can help an attacker compromise the confidentiality of sensitive data. This vulnerability may lead an attacker to get unexpected authorization.\u003c/p\u003e"
}
],
"value": "A weak cryptographic algorithm vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. This vulnerability can help an attacker compromise the confidentiality of sensitive data. This vulnerability may lead an attacker to get unexpected authorization."
}
],
"impacts": [
{
"capecId": "CAPEC-20",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-20: Encryption Brute Forcing"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-328",
"description": "CWE-328: Use of Weak Hash",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T06:14:46.184Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eioLogik E1200 Series : Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v3.3.7).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \n\n\n\n * ioLogik E1200 Series : Please contact Moxa Technical Support for the security patch (v3.3.7). https://www.moxa.com/tw/support/technical-support"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "ioLogik E1200 Series: Weak Cryptographic Algorithm Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-5962",
"datePublished": "2023-12-23T09:09:01.920Z",
"dateReserved": "2023-11-06T07:47:33.243Z",
"dateUpdated": "2024-10-28T06:14:46.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5961 (GCVE-0-2023-5961)
Vulnerability from cvelistv5 – Published: 2023-12-23 09:01 – Updated: 2024-11-27 18:28- CWE-352 - Cross-Site Request Forgery (CSRF)
| URL | Tags |
|---|---|
| https://www.moxa.com/en/support/product-support/s… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | ioLogik E1200 Series |
Affected:
1.0 , ≤ 3.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.125Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5961",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T18:28:26.021021Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T18:28:44.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ioLogik E1200 Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "3.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reza Rashidi from HADESS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA Cross-Site Request Forgery (CSRF) vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. An attacker can exploit this vulnerability to trick a client into making an unintentional request to the web server, which will be treated as an authentic request. This vulnerability may lead an attacker to perform operations on behalf of the victimized user.\u003c/p\u003e"
}
],
"value": "A Cross-Site Request Forgery (CSRF) vulnerability has been identified in ioLogik E1200 Series firmware versions v3.3 and prior. An attacker can exploit this vulnerability to trick a client into making an unintentional request to the web server, which will be treated as an authentic request. This vulnerability may lead an attacker to perform operations on behalf of the victimized user.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-62",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-62: Cross Site Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-23T09:01:02.875Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-235250-iologik-e1200-series-web-server-vulnerability"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \u003c/p\u003e\u003cul\u003e\u003cli\u003eioLogik E1200 Series : Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v3.3.7).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below. \n\n * ioLogik E1200 Series : Please contact Moxa Technical Support for the security patch (v3.3.7). https://www.moxa.com/tw/support/technical-support \n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "ioLogik E1200 Series: Cross-Site Request Forgery (CSRF) Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-5961",
"datePublished": "2023-12-23T09:01:02.875Z",
"dateReserved": "2023-11-06T07:47:31.237Z",
"dateUpdated": "2024-11-27T18:28:44.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CERTFR-2026-AVI-1589
Vulnerability from certfr_avis - Published: 2026-11-20 - Updated: 2026-11-20
De multiples vulnérabilités ont été découvertes dans les produits Moxa. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Aucun correctif n'est disponible pour les vulnérabilités CVE-2026-130493 et CVE-2026-130494, Moxa recommande de suivre les mesures de contournement préconisées dans le bulletin de sécurité.
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Moxa | N/A | les commutateurs Moxa, se référer au bulletin de sécurité de l'éditeur pour la liste des appareils vulnérables (cf. section Documentation). | ||
| Moxa | ioLogik E1200 Series | ioLogik E1200 versions antérieures à 4.0.5 |
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "les commutateurs Moxa, se r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour la liste des appareils vuln\u00e9rables (cf. section Documentation).",
"product": {
"name": "N/A",
"vendor": {
"name": "Moxa",
"scada": true
}
}
},
{
"description": "ioLogik E1200 versions ant\u00e9rieures \u00e0 4.0.5",
"product": {
"name": "ioLogik E1200 Series",
"vendor": {
"name": "Moxa",
"scada": true
}
}
}
],
"affected_systems_content": "Aucun correctif n\u0027est disponible pour les vuln\u00e9rabilit\u00e9s CVE-2026-130493 et CVE-2026-130494, Moxa recommande de suivre les mesures de contournement pr\u00e9conis\u00e9es dans le bulletin de s\u00e9curit\u00e9.",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2026-130494",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-130494"
},
{
"name": "CVE-2026-130493",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-130493"
},
{
"name": "CVE-2026-129972",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-129972"
},
{
"name": "CVE-2026-129971",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-129971"
}
],
"initial_release_date": "2026-11-20T00:00:00",
"last_revision_date": "2026-11-20T00:00:00",
"links": [],
"reference": "CERTFR-2026-AVI-1589",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2026-11-20T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Moxa. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Moxa",
"vendor_advisories": [
{
"published_at": "2026-11-20",
"title": "Bulletin de s\u00e9curit\u00e9 Moxa MPSA-264520",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-264520-cve-2026-129971,-cve-2026-129972-buffer-overflow-vulnerabilities-in-ethernet-remote-i-os"
},
{
"published_at": "2026-11-20",
"title": "Bulletin de s\u00e9curit\u00e9 Moxa MPSA-268140",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-268140-cve-2026-130493,-cve-2026-130494-multiple-vulnerabilities-in-ethernet-switches"
}
]
}
CERTFR-2025-AVI-1046
Vulnerability from certfr_avis - Published: 2025-11-28 - Updated: 2025-11-28
De multiples vulnérabilités ont été découvertes dans les produits Moxa. Elles permettent à un attaquant de provoquer une atteinte à la confidentialité des données et un contournement de la politique de sécurité.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Moxa | ioLogik E2200 Series | ioLogik E2200 Series toutes versions | ||
| Moxa | ioLogik E1200 Series | ioLogik E1200 Series toutes versions |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "ioLogik E2200 Series toutes versions",
"product": {
"name": "ioLogik E2200 Series",
"vendor": {
"name": "Moxa",
"scada": true
}
}
},
{
"description": "ioLogik E1200 Series toutes versions",
"product": {
"name": "ioLogik E1200 Series",
"vendor": {
"name": "Moxa",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [],
"initial_release_date": "2025-11-28T00:00:00",
"last_revision_date": "2025-11-28T00:00:00",
"links": [],
"reference": "CERTFR-2025-AVI-1046",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-11-28T00:00:00.000000"
}
],
"risks": [
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Moxa. Elles permettent \u00e0 un attaquant de provoquer une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et un contournement de la politique de s\u00e9curit\u00e9.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Moxa",
"vendor_advisories": [
{
"published_at": "2025-11-27",
"title": "Bulletin de s\u00e9curit\u00e9 Moxa mpsa-252213",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-252213-security-enhancement-web-application-potentially-vulnerable-to-clickjacking"
},
{
"published_at": "2025-11-27",
"title": "Bulletin de s\u00e9curit\u00e9 Moxa mpsa-252211",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-252211-security-enhancement-web-server-transmits-cleartext-credentials"
},
{
"published_at": "2025-11-27",
"title": "Bulletin de s\u00e9curit\u00e9 Moxa mpsa-252212",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-252212-security-enhancement-web-server-allows-password-auto-completion"
}
]
}