Search
Find a vulnerability
Search criteria
10 vulnerabilities found for iDRAC9 by Dell
CVE-2026-23855 (GCVE-0-2026-23855)
Vulnerability from nvd – Published: 2026-09-09 16:02 – Updated: 2026-09-11 03:56
VLAI
EPSS
VEX
Summary
Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 00:00 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050499… | vendor-advisory |
Impacted products
Date Public
2026-09-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23855",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-11T03:56:14.162Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.30.10.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.00.00.184 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iDRAC10",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.30.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-09-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection."
}
],
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T16:02:57.391Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000504998/dsa-2026-392-security-update-for-dell-idrac9-and-idrac10-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-23855",
"datePublished": "2026-09-09T16:02:57.391Z",
"dateReserved": "2026-01-16T18:05:07.319Z",
"dateUpdated": "2026-09-11T03:56:14.162Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-79940 (GCVE-0-2026-79940)
Vulnerability from nvd – Published: 2026-08-26 18:16 – Updated: 2026-08-26 19:46
VLAI
EPSS
VEX
Summary
Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-26 19:32 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050251… | vendor-advisory |
Impacted products
Date Public
2026-08-25 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-79940",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T19:32:50.836419Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T19:46:27.415Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.20.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.00.00.182 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-08-25T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data."
}
],
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T18:16:42.618Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000502514/dsa-2026-374-security-update-for-dell-idrac9-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-79940",
"datePublished": "2026-08-26T18:16:42.618Z",
"dateReserved": "2026-08-25T15:04:54.600Z",
"dateUpdated": "2026-08-26T19:46:27.415Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-70412 (GCVE-0-2026-70412)
Vulnerability from nvd – Published: 2026-08-17 13:04 – Updated: 2026-08-17 14:31
VLAI
EPSS
VEX
Summary
Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 14:30 UTC
CWE
- CWE-1330 - Remanent Data Readable after Memory Erase
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00049790… | vendor-advisory |
Impacted products
Date Public
2026-08-10 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-70412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T14:30:51.665942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T14:31:28.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.20.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iDRAC10",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.20.60.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-08-10T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1330",
"description": "CWE-1330: Remanent Data Readable after Memory Erase",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T13:04:52.184Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000497902/dsa-2026-348-security-update-for-dell-idrac9-and-idrac10-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-70412",
"datePublished": "2026-08-17T13:04:52.184Z",
"dateReserved": "2026-08-04T11:16:10.499Z",
"dateUpdated": "2026-08-17T14:31:28.807Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-25943 (GCVE-0-2024-25943)
Vulnerability from nvd – Published: 2024-06-29 12:52 – Updated: 2024-08-01 23:52
VLAI
EPSS
VEX
Summary
iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-02 19:10 UTC
CWE
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00022650… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
N/A , < 7.00.00.172
(semver)
Affected: N/A , < 7.10.50.00 (semver) |
|
| dell | integrated_dell_remote_access_controller_9_firmware |
Affected:
0 , < 7.00.00.172
(semver)
Affected: 0 , < 7.10.50.00 (semver) cpe:2.3:o:dell:integrated_dell_remote_access_controller_9_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-06-28 06:30
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:integrated_dell_remote_access_controller_9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "integrated_dell_remote_access_controller_9_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "7.00.00.172",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.10.50.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25943",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-02T19:10:06.274139Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-02T19:19:06.056Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.350Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226503/dsa-2024-099-security-update-for-dell-idrac9-ipmi-session-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.00.00.172",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.50.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-06-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application."
}
],
"value": "iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330: Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-29T12:52:27.699Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226503/dsa-2024-099-security-update-for-dell-idrac9-ipmi-session-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25943",
"datePublished": "2024-06-29T12:52:27.699Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-01T23:52:06.350Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24422 (GCVE-0-2022-24422)
Vulnerability from nvd – Published: 2022-05-26 15:20 – Updated: 2024-09-16 22:31
VLAI
EPSS
VEX
Summary
Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console.
Severity
9.6 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00019926… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
unspecified , < 5.10.10.00
(custom)
|
Date Public
2022-05-11 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:13:55.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.10.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-11T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-26T15:20:22.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2022-05-11",
"ID": "CVE-2022-24422",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller 9",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.10.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.6,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-24422",
"datePublished": "2022-05-26T15:20:22.189Z",
"dateReserved": "2022-02-04T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:31:28.430Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-23855 (GCVE-0-2026-23855)
Vulnerability from cvelistv5 – Published: 2026-09-09 16:02 – Updated: 2026-09-11 03:56
VLAI
EPSS
VEX
Summary
Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 00:00 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050499… | vendor-advisory |
Impacted products
Date Public
2026-09-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23855",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-11T03:56:14.162Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.30.10.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.00.00.184 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iDRAC10",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.30.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-09-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection."
}
],
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T16:02:57.391Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000504998/dsa-2026-392-security-update-for-dell-idrac9-and-idrac10-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-23855",
"datePublished": "2026-09-09T16:02:57.391Z",
"dateReserved": "2026-01-16T18:05:07.319Z",
"dateUpdated": "2026-09-11T03:56:14.162Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-79940 (GCVE-0-2026-79940)
Vulnerability from cvelistv5 – Published: 2026-08-26 18:16 – Updated: 2026-08-26 19:46
VLAI
EPSS
VEX
Summary
Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-26 19:32 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050251… | vendor-advisory |
Impacted products
Date Public
2026-08-25 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-79940",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T19:32:50.836419Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T19:46:27.415Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.20.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.00.00.182 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-08-25T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data."
}
],
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.182 and 15G/16G versions prior to 7.20.30.50, contains an Improper Access Control vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to gaining access to unauthorized data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T18:16:42.618Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000502514/dsa-2026-374-security-update-for-dell-idrac9-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-79940",
"datePublished": "2026-08-26T18:16:42.618Z",
"dateReserved": "2026-08-25T15:04:54.600Z",
"dateUpdated": "2026-08-26T19:46:27.415Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-70412 (GCVE-0-2026-70412)
Vulnerability from cvelistv5 – Published: 2026-08-17 13:04 – Updated: 2026-08-17 14:31
VLAI
EPSS
VEX
Summary
Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 14:30 UTC
CWE
- CWE-1330 - Remanent Data Readable after Memory Erase
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00049790… | vendor-advisory |
Impacted products
Date Public
2026-08-10 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-70412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T14:30:51.665942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T14:31:28.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iDRAC9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.20.30.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iDRAC10",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.20.60.50 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-08-10T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell iDRAC9, versions prior to 7.20.30.50, and Dell iDRAC10, version prior to 1.20.60.50, contain a Remanent Data Readable after Memory Erase vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1330",
"description": "CWE-1330: Remanent Data Readable after Memory Erase",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T13:04:52.184Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000497902/dsa-2026-348-security-update-for-dell-idrac9-and-idrac10-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-70412",
"datePublished": "2026-08-17T13:04:52.184Z",
"dateReserved": "2026-08-04T11:16:10.499Z",
"dateUpdated": "2026-08-17T14:31:28.807Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-25943 (GCVE-0-2024-25943)
Vulnerability from cvelistv5 – Published: 2024-06-29 12:52 – Updated: 2024-08-01 23:52
VLAI
EPSS
VEX
Summary
iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-02 19:10 UTC
CWE
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00022650… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
N/A , < 7.00.00.172
(semver)
Affected: N/A , < 7.10.50.00 (semver) |
|
| dell | integrated_dell_remote_access_controller_9_firmware |
Affected:
0 , < 7.00.00.172
(semver)
Affected: 0 , < 7.10.50.00 (semver) cpe:2.3:o:dell:integrated_dell_remote_access_controller_9_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-06-28 06:30
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:integrated_dell_remote_access_controller_9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "integrated_dell_remote_access_controller_9_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "7.00.00.172",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.10.50.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25943",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-02T19:10:06.274139Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-02T19:19:06.056Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.350Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226503/dsa-2024-099-security-update-for-dell-idrac9-ipmi-session-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThan": "7.00.00.172",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.50.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-06-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application."
}
],
"value": "iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330: Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-29T12:52:27.699Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226503/dsa-2024-099-security-update-for-dell-idrac9-ipmi-session-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25943",
"datePublished": "2024-06-29T12:52:27.699Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-01T23:52:06.350Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24422 (GCVE-0-2022-24422)
Vulnerability from cvelistv5 – Published: 2022-05-26 15:20 – Updated: 2024-09-16 22:31
VLAI
EPSS
VEX
Summary
Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console.
Severity
9.6 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00019926… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
unspecified , < 5.10.10.00
(custom)
|
Date Public
2022-05-11 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:13:55.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.10.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-11T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-26T15:20:22.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2022-05-11",
"ID": "CVE-2022-24422",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller 9",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.10.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.6,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-24422",
"datePublished": "2022-05-26T15:20:22.189Z",
"dateReserved": "2022-02-04T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:31:28.430Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}