Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for cx-position by omron

    CVE-2022-26419 (GCVE-0-2022-26419)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Code Injection
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.898Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26419",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:14.434621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:14.774Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:15.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Code Injection",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26419",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Code Injection"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26419",
        "datePublished": "2022-04-01T22:17:56.304Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:14.774Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26417 (GCVE-0-2022-26417)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Use After Free
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.822Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26417",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:20.339620Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:32.232Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use After Free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:07.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Use After Free",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26417",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Use After Free"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-416 Use After Free"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26417",
        "datePublished": "2022-04-01T22:17:53.991Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:32.232Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26022 (GCVE-0-2022-26022)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:36.910Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26022",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:17.037995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:23.967Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26022",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787 Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26022",
        "datePublished": "2022-04-01T22:17:55.227Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:23.967Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-25959 (GCVE-0-2022-25959)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:36.490Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-25959",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:23.242858Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:41.902Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:08.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-25959",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-25959",
        "datePublished": "2022-04-01T22:17:53.047Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:41.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27261 (GCVE-0-2020-27261)

    Vulnerability from nvd – Published: 2021-02-09 14:09 – Updated: 2024-09-17 00:02
    VLAI
    Title
    Omron CX-One
    Summary
    The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.439Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:17.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27261",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27261",
        "datePublished": "2021-02-09T14:09:34.782Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:02:18.058Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27259 (GCVE-0-2020-27259)

    Vulnerability from nvd – Published: 2021-02-09 14:09 – Updated: 2024-09-16 16:33
    VLAI
    Title
    Omron CX-One
    Summary
    The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-822 - UNTRUSTED POINTER DEREFERENCE CWE-822
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-822",
                  "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:18.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27259",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27259",
        "datePublished": "2021-02-09T14:09:11.732Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:33:13.557Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27257 (GCVE-0-2020-27257)

    Vulnerability from nvd – Published: 2021-02-09 14:10 – Updated: 2024-09-17 02:47
    VLAI
    Title
    Omron CX-One
    Summary
    This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices.
    Severity
    No CVSS data available.
    CWE
    • CWE-843 - ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.464Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-843",
                  "description": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:13.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27257",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27257",
        "datePublished": "2021-02-09T14:10:19.507Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:47:28.530Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26419 (GCVE-0-2022-26419)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Code Injection
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.898Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26419",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:14.434621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:14.774Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:15.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Code Injection",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26419",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Code Injection"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-580/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-579/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-576/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-575/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26419",
        "datePublished": "2022-04-01T22:17:56.304Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:14.774Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26022 (GCVE-0-2022-26022)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:36.910Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26022",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:17.037995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:23.967Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26022",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787 Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-581/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26022",
        "datePublished": "2022-04-01T22:17:55.227Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:23.967Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26417 (GCVE-0-2022-26417)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Use After Free
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.822Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26417",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:20.339620Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:32.232Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use After Free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:07.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Use After Free",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-26417",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Use After Free"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-416 Use After Free"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-578/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-26417",
        "datePublished": "2022-04-01T22:17:53.991Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:32.232Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-25959 (GCVE-0-2022-25959)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 17:57
    VLAI
    Title
    Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer
    Summary
    Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:30 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    References
    Impacted products
    Vendor Product Version
    Omron CX-Position Affected: unspecified , ≤ 2.5.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:36.490Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-25959",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:30:23.242858Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:57:41.902Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-05T15:06:08.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-02",
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T19:11:00.000Z",
              "ID": "CVE-2022-25959",
              "STATE": "PUBLIC",
              "TITLE": "Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.5.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-577/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Omron has provided Version 2.5.4, which is only available to paying users who use the \u201cAuto Update\u201d function. Please contact Omron technical Support or an Omron representative for specific update information."
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-25959",
        "datePublished": "2022-04-01T22:17:53.047Z",
        "dateReserved": "2022-03-21T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:57:41.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27257 (GCVE-0-2020-27257)

    Vulnerability from cvelistv5 – Published: 2021-02-09 14:10 – Updated: 2024-09-17 02:47
    VLAI
    Title
    Omron CX-One
    Summary
    This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices.
    Severity
    No CVSS data available.
    CWE
    • CWE-843 - ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.464Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-843",
                  "description": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:13.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27257",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-184/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27257",
        "datePublished": "2021-02-09T14:10:19.507Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:47:28.530Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27261 (GCVE-0-2020-27261)

    Vulnerability from cvelistv5 – Published: 2021-02-09 14:09 – Updated: 2024-09-17 00:02
    VLAI
    Title
    Omron CX-One
    Summary
    The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.439Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:17.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27261",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-183/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-185/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27261",
        "datePublished": "2021-02-09T14:09:34.782Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:02:18.058Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27259 (GCVE-0-2020-27259)

    Vulnerability from cvelistv5 – Published: 2021-02-09 14:09 – Updated: 2024-09-16 16:33
    VLAI
    Title
    Omron CX-One
    Summary
    The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-822 - UNTRUSTED POINTER DEREFERENCE CWE-822
    Impacted products
    Vendor Product Version
    Omron CX-One Affected: unspecified , ≤ 4.60 (custom)
    Create a notification for this product.
    Omron CX-Protocol Affected: unspecified , ≤ 2.02 (custom)
    Create a notification for this product.
    Omron CX-Server Affected: unspecified , ≤ 5.0.28 (custom)
    Create a notification for this product.
    Omron CX-Position Affected: unspecified , ≤ 2.52 (custom)
    Create a notification for this product.
    Date Public
    2021-01-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CX-One",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "4.60",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Protocol",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.02",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Server",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.28",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CX-Position",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThanOrEqual": "2.52",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-01-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-822",
                  "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-10T18:06:18.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
            }
          ],
          "source": {
            "advisory": "ICSA-21-007-02",
            "discovery": "UNKNOWN"
          },
          "title": "Omron CX-One",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-01-07T17:00:00.000Z",
              "ID": "CVE-2020-27259",
              "STATE": "PUBLIC",
              "TITLE": "Omron CX-One"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CX-One",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.60"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Protocol",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.02"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.0.28"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CX-Position",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "2.52"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Omron"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-182/"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-007-02",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27259",
        "datePublished": "2021-02-09T14:09:11.732Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:33:13.557Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",