Search

Find a vulnerability

Search criteria

    42 vulnerabilities found for cloudlink by dell

    CVE-2025-46424 (GCVE-0-2025-46424)

    Vulnerability from nvd – Published: 2025-11-05 16:46 – Updated: 2026-11-03 22:03
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46424",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:41.464834Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:03:04.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1240",
                  "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:46:25.707Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46424",
        "datePublished": "2025-11-05T16:46:25.707Z",
        "dateReserved": "2025-04-24T05:03:44.662Z",
        "dateUpdated": "2026-11-03T22:03:04.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46366 (GCVE-0-2025-46366)

    Vulnerability from nvd – Published: 2025-11-05 16:50 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-256 - Plaintext Storage of a Password
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:42.512382Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:12.528Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue."
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256: Plaintext Storage of a Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:50:28.754Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46366",
        "datePublished": "2025-11-05T16:50:28.754Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:12.528Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46365 (GCVE-0-2025-46365)

    Vulnerability from nvd – Published: 2025-11-05 16:40 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46365",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:40.610497Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:13.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
                }
              ],
              "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:40:39.934Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46365",
        "datePublished": "2025-11-05T16:40:39.934Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:13.147Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46364 (GCVE-0-2025-46364)

    Vulnerability from nvd – Published: 2025-11-05 16:36 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    References
    Impacted products
    Vendor Product Version
    Dell CloudLin Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46364",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:39.793430Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:13.534Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLin",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:36:00.347Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46364",
        "datePublished": "2025-11-05T16:36:00.347Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:13.534Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-45379 (GCVE-0-2025-45379)

    Vulnerability from nvd – Published: 2025-11-05 16:31 – Updated: 2026-11-03 22:03
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45379",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:38.895071Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:03:04.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:31:57.457Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-45379",
        "datePublished": "2025-11-05T16:31:57.457Z",
        "dateReserved": "2025-04-22T05:03:45.359Z",
        "dateUpdated": "2026-11-03T22:03:04.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-45378 (GCVE-0-2025-45378)

    Vulnerability from nvd – Published: 2025-11-05 16:23 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system. If ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 8.0 , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45378",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:37.130318Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:16.150Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\u003cbr\u003e\u003cbr\u003eIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
                }
              ],
              "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\n\nIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:23:15.673Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-45378",
        "datePublished": "2025-11-05T16:23:15.673Z",
        "dateReserved": "2025-04-22T05:03:45.359Z",
        "dateUpdated": "2026-02-26T17:47:16.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-30479 (GCVE-0-2025-30479)

    Vulnerability from nvd – Published: 2025-11-05 16:27 – Updated: 2026-11-03 22:02
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30479",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:38.074331Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:02:57.780Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:27:33.266Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-30479",
        "datePublished": "2025-11-05T16:27:33.266Z",
        "dateReserved": "2025-03-23T18:45:23.729Z",
        "dateUpdated": "2026-11-03T22:02:57.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-26484 (GCVE-0-2025-26484)

    Vulnerability from nvd – Published: 2025-08-14 14:24 – Updated: 2025-08-14 14:48
    VLAI
    Summary
    Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-14 14:47 UTC
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 8.0 , ≤ 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-08-13 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-26484",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-14T14:47:55.328704Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-14T14:48:08.369Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "8.1.1",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue"
            }
          ],
          "datePublic": "2025-08-13T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
                }
              ],
              "value": "Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-14T14:24:13.765Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000356343/dsa-2025-321-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-26484",
        "datePublished": "2025-08-14T14:24:13.765Z",
        "dateReserved": "2025-02-11T06:06:12.147Z",
        "dateUpdated": "2025-08-14T14:48:08.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-38482 (GCVE-0-2024-38482)

    Vulnerability from nvd – Published: 2024-08-02 04:12 – Updated: 2024-08-02 17:38
    VLAI
    Summary
    CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-02 17:38 UTC
    CWE
    • CWE-703 - Improper Check or Handling of Exceptional Conditions
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1 (semver)
    Create a notification for this product.
    Date Public
    2024-08-01 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-38482",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-02T17:38:10.800621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:38:31.532Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank B4gpipe for reporting this issue."
            }
          ],
          "datePublic": "2024-08-01T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u0026nbsp; CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database."
                }
              ],
              "value": "CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-703",
                  "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-02T04:12:12.391Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000227493/dsa-2024-343-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-38482",
        "datePublished": "2024-08-02T04:12:12.391Z",
        "dateReserved": "2024-06-18T01:53:34.135Z",
        "dateUpdated": "2024-08-02T17:38:31.532Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37137 (GCVE-0-2024-37137)

    Vulnerability from nvd – Published: 2024-06-28 01:33 – Updated: 2024-08-02 03:50
    VLAI
    Summary
    Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-01 20:25 UTC
    CWE
    • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 7.1.9 (semver)
    Create a notification for this product.
    Date Public
    2024-06-27 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37137",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-01T20:25:40.409526Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-01T21:23:45.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:50:54.819Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000226476/dsa-2024-294-security-update-for-dell-cloudlink-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.9",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2024-06-27T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure."
                }
              ],
              "value": "Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1240",
                  "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-28T01:33:42.186Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000226476/dsa-2024-294-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-37137",
        "datePublished": "2024-06-28T01:33:42.186Z",
        "dateReserved": "2024-06-03T12:10:32.205Z",
        "dateUpdated": "2024-08-02T03:50:54.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-28076 (GCVE-0-2023-28076)

    Vulnerability from nvd – Published: 2023-05-16 15:26 – Updated: 2025-01-22 20:50
    VLAI
    Summary
    CloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-22 20:50 UTC
    CWE
    • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 7.1.2 and all prior versions
    Create a notification for this product.
    Date Public
    2023-04-05 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:30:24.268Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000212095/dsa-2023-121-dell-cloudlink-security-update-for-aes-gcm-ciphers-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-28076",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-22T20:50:02.606276Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-22T20:50:06.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "7.1.2 and all prior versions"
                }
              ]
            }
          ],
          "datePublic": "2023-04-05T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nCloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-16T15:26:19.265Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000212095/dsa-2023-121-dell-cloudlink-security-update-for-aes-gcm-ciphers-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-28076",
        "datePublished": "2023-05-16T15:26:19.265Z",
        "dateReserved": "2023-03-10T05:10:02.997Z",
        "dateUpdated": "2025-01-22T20:50:06.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34380 (GCVE-0-2022-34380)

    Vulnerability from nvd – Published: 2022-09-01 18:45 – Updated: 2024-09-16 23:30
    VLAI
    Summary
    Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.4 (custom)
    Create a notification for this product.
    Date Public
    2022-08-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.307Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-01T18:45:19.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-01",
              "ID": "CVE-2022-34380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 9.3,
                "baseSeverity": "Critical",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287: Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34380",
        "datePublished": "2022-09-01T18:45:19.634Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:30:42.245Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34379 (GCVE-0-2022-34379)

    Vulnerability from nvd – Published: 2022-09-01 18:45 – Updated: 2024-09-16 16:13
    VLAI
    Summary
    Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.3 (custom)
    Create a notification for this product.
    Date Public
    2022-08-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.241Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-01T18:45:18.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-01",
              "ID": "CVE-2022-34379",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 9.4,
                "baseSeverity": "Critical",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287: Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34379",
        "datePublished": "2022-09-01T18:45:18.835Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:13:20.117Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-24414 (GCVE-0-2022-24414)

    Vulnerability from nvd – Published: 2022-05-26 15:20 – Updated: 2024-09-17 00:55
    VLAI
    Summary
    Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks.
    CWE
    • CWE-598 - Information Exposure Through Query Strings in GET Request
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-16 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:13:55.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-03-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-598",
                  "description": "CWE-598: Information Exposure Through Query Strings in GET Request",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-26T15:20:17.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-03-16",
              "ID": "CVE-2022-24414",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 7.6,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-598: Information Exposure Through Query Strings in GET Request"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-24414",
        "datePublished": "2022-05-26T15:20:17.669Z",
        "dateReserved": "2022-02-04T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:55:43.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36335 (GCVE-0-2021-36335)

    Vulnerability from nvd – Published: 2021-11-23 20:00 – Updated: 2024-09-16 16:53
    VLAI
    Summary
    Dell EMC CloudLink 7.1 and all prior versions contain an Improper Input Validation Vulnerability. A remote low privileged attacker, may potentially exploit this vulnerability, leading to execution of arbitrary files on the server
    CWE
    • CWE-20 - Improper Input Validation
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.1 (custom)
    Create a notification for this product.
    Date Public
    2021-11-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:54:51.457Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1 and all prior versions contain an Improper Input Validation Vulnerability. A remote low privileged attacker, may potentially exploit this vulnerability, leading to execution of arbitrary files on the server"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-23T20:00:45.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2021-11-01",
              "ID": "CVE-2021-36335",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1 and all prior versions contain an Improper Input Validation Vulnerability. A remote low privileged attacker, may potentially exploit this vulnerability, leading to execution of arbitrary files on the server"
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 4.3,
                "baseSeverity": "Medium",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20: Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2021-36335",
        "datePublished": "2021-11-23T20:00:45.951Z",
        "dateReserved": "2021-07-08T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:53:37.374Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36334 (GCVE-0-2021-36334)

    Vulnerability from nvd – Published: 2021-11-23 20:00 – Updated: 2024-09-16 20:22
    VLAI
    Summary
    Dell EMC CloudLink 7.1 and all prior versions contain a CSV formula Injection Vulnerability. A remote high privileged attacker, may potentially exploit this vulnerability, leading to arbitrary code execution on end user machine
    CWE
    • Other
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.1 (custom)
    Create a notification for this product.
    Date Public
    2021-11-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:54:51.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1 and all prior versions contain a CSV formula Injection Vulnerability. A remote high privileged attacker, may potentially exploit this vulnerability, leading to arbitrary code execution on end user machine"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Other",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-23T20:00:44.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2021-11-01",
              "ID": "CVE-2021-36334",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1 and all prior versions contain a CSV formula Injection Vulnerability. A remote high privileged attacker, may potentially exploit this vulnerability, leading to arbitrary code execution on end user machine"
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Other"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000193031/https-dellservices-lightning-force-com-one-one-app"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2021-36334",
        "datePublished": "2021-11-23T20:00:44.446Z",
        "dateReserved": "2021-07-08T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:22:58.890Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-46366 (GCVE-0-2025-46366)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:50 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-256 - Plaintext Storage of a Password
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:42.512382Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:12.528Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue."
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256: Plaintext Storage of a Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:50:28.754Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46366",
        "datePublished": "2025-11-05T16:50:28.754Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:12.528Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46424 (GCVE-0-2025-46424)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:46 – Updated: 2026-11-03 22:03
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46424",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:41.464834Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:03:04.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1240",
                  "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:46:25.707Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46424",
        "datePublished": "2025-11-05T16:46:25.707Z",
        "dateReserved": "2025-04-24T05:03:44.662Z",
        "dateUpdated": "2026-11-03T22:03:04.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46365 (GCVE-0-2025-46365)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:40 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46365",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:40.610497Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:13.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
                }
              ],
              "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:40:39.934Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46365",
        "datePublished": "2025-11-05T16:40:39.934Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:13.147Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-46364 (GCVE-0-2025-46364)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:36 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    References
    Impacted products
    Vendor Product Version
    Dell CloudLin Affected: N/A , < 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-46364",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:39.793430Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:13.534Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLin",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:36:00.347Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-46364",
        "datePublished": "2025-11-05T16:36:00.347Z",
        "dateReserved": "2025-04-23T05:03:43.135Z",
        "dateUpdated": "2026-02-26T17:47:13.534Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-45379 (GCVE-0-2025-45379)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:31 – Updated: 2026-11-03 22:03
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45379",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:38.895071Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:03:04.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:31:57.457Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-45379",
        "datePublished": "2025-11-05T16:31:57.457Z",
        "dateReserved": "2025-04-22T05:03:45.359Z",
        "dateUpdated": "2026-11-03T22:03:04.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-30479 (GCVE-0-2025-30479)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:27 – Updated: 2026-11-03 22:02
    VLAI
    Summary
    Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30479",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:38.074331Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T22:02:57.780Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
                }
              ],
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:27:33.266Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-30479",
        "datePublished": "2025-11-05T16:27:33.266Z",
        "dateReserved": "2025-03-23T18:45:23.729Z",
        "dateUpdated": "2026-11-03T22:02:57.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-45378 (GCVE-0-2025-45378)

    Vulnerability from cvelistv5 – Published: 2025-11-05 16:23 – Updated: 2026-02-26 17:47
    VLAI
    Summary
    Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system. If ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-11-06 04:55 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 8.0 , < 8.2 (semver)
    Create a notification for this product.
    Date Public
    2025-10-29 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45378",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-06T04:55:37.130318Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:47:16.150Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.2",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-10-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\u003cbr\u003e\u003cbr\u003eIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
                }
              ],
              "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\n\nIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-05T16:23:15.673Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-45378",
        "datePublished": "2025-11-05T16:23:15.673Z",
        "dateReserved": "2025-04-22T05:03:45.359Z",
        "dateUpdated": "2026-02-26T17:47:16.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-26484 (GCVE-0-2025-26484)

    Vulnerability from cvelistv5 – Published: 2025-08-14 14:24 – Updated: 2025-08-14 14:48
    VLAI
    Summary
    Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-14 14:47 UTC
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 8.0 , ≤ 8.1.1 (semver)
    Create a notification for this product.
    Date Public
    2025-08-13 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-26484",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-14T14:47:55.328704Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-14T14:48:08.369Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "8.1.1",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue"
            }
          ],
          "datePublic": "2025-08-13T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
                }
              ],
              "value": "Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-14T14:24:13.765Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000356343/dsa-2025-321-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-26484",
        "datePublished": "2025-08-14T14:24:13.765Z",
        "dateReserved": "2025-02-11T06:06:12.147Z",
        "dateUpdated": "2025-08-14T14:48:08.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-38482 (GCVE-0-2024-38482)

    Vulnerability from cvelistv5 – Published: 2024-08-02 04:12 – Updated: 2024-08-02 17:38
    VLAI
    Summary
    CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-02 17:38 UTC
    CWE
    • CWE-703 - Improper Check or Handling of Exceptional Conditions
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 8.1 (semver)
    Create a notification for this product.
    Date Public
    2024-08-01 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-38482",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-02T17:38:10.800621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:38:31.532Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "8.1",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank B4gpipe for reporting this issue."
            }
          ],
          "datePublic": "2024-08-01T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u0026nbsp; CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database."
                }
              ],
              "value": "CloudLink, versions 7.1.x and 8.x, contain an Improper check or handling of Exceptional Conditions Vulnerability in Cluster Component. A highly privileged malicious user with remote access could potentially exploit this vulnerability, leading to execute unauthorized actions and retrieve sensitive information from the database."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-703",
                  "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-02T04:12:12.391Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000227493/dsa-2024-343-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-38482",
        "datePublished": "2024-08-02T04:12:12.391Z",
        "dateReserved": "2024-06-18T01:53:34.135Z",
        "dateUpdated": "2024-08-02T17:38:31.532Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37137 (GCVE-0-2024-37137)

    Vulnerability from cvelistv5 – Published: 2024-06-28 01:33 – Updated: 2024-08-02 03:50
    VLAI
    Summary
    Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-01 20:25 UTC
    CWE
    • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: N/A , < 7.1.9 (semver)
    Create a notification for this product.
    Date Public
    2024-06-27 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37137",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-01T20:25:40.409526Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-01T21:23:45.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:50:54.819Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000226476/dsa-2024-294-security-update-for-dell-cloudlink-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.9",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2024-06-27T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure."
                }
              ],
              "value": "Dell Key Trust Platform, v3.0.6 and prior, contains Use of a Cryptographic Primitive with a Risky Implementation vulnerability. A local privileged attacker could potentially exploit this vulnerability, leading to privileged information disclosure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1240",
                  "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-28T01:33:42.186Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000226476/dsa-2024-294-security-update-for-dell-cloudlink-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-37137",
        "datePublished": "2024-06-28T01:33:42.186Z",
        "dateReserved": "2024-06-03T12:10:32.205Z",
        "dateUpdated": "2024-08-02T03:50:54.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-28076 (GCVE-0-2023-28076)

    Vulnerability from cvelistv5 – Published: 2023-05-16 15:26 – Updated: 2025-01-22 20:50
    VLAI
    Summary
    CloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-22 20:50 UTC
    CWE
    • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: 7.1.2 and all prior versions
    Create a notification for this product.
    Date Public
    2023-04-05 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:30:24.268Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000212095/dsa-2023-121-dell-cloudlink-security-update-for-aes-gcm-ciphers-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-28076",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-22T20:50:02.606276Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-22T20:50:06.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "7.1.2 and all prior versions"
                }
              ]
            }
          ],
          "datePublic": "2023-04-05T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nCloudLink 7.1.2 and all prior versions contain a broken or risky cryptographic algorithm vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability leading to some information disclosure.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-16T15:26:19.265Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000212095/dsa-2023-121-dell-cloudlink-security-update-for-aes-gcm-ciphers-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-28076",
        "datePublished": "2023-05-16T15:26:19.265Z",
        "dateReserved": "2023-03-10T05:10:02.997Z",
        "dateUpdated": "2025-01-22T20:50:06.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34380 (GCVE-0-2022-34380)

    Vulnerability from cvelistv5 – Published: 2022-09-01 18:45 – Updated: 2024-09-16 23:30
    VLAI
    Summary
    Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.4 (custom)
    Create a notification for this product.
    Date Public
    2022-08-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.307Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-01T18:45:19.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-01",
              "ID": "CVE-2022-34380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell CloudLink 7.1.3 and all earlier versions contain an Authentication Bypass Using an Alternate Path or Channel Vulnerability. A high privileged local attacker may potentially exploit this vulnerability leading to authentication bypass and access the CloudLink system console. This is critical severity vulnerability as it allows attacker to take control of the system."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 9.3,
                "baseSeverity": "Critical",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287: Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202058/dsa-2022-210-dell-emc-cloudlink-security-update-for-multiple-security-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34380",
        "datePublished": "2022-09-01T18:45:19.634Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:30:42.245Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34379 (GCVE-0-2022-34379)

    Vulnerability from cvelistv5 – Published: 2022-09-01 18:45 – Updated: 2024-09-16 16:13
    VLAI
    Summary
    Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system.
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.3 (custom)
    Create a notification for this product.
    Date Public
    2022-08-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.241Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-01T18:45:18.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-01",
              "ID": "CVE-2022-34379",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1.2 and all prior versions contain an Authentication Bypass Vulnerability. A remote attacker, with the knowledge of the active directory usernames, could potentially exploit this vulnerability to gain unauthorized access to the system."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 9.4,
                "baseSeverity": "Critical",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287: Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202057/dsa-2022-207-dell-emc-cloudlink-security-update-for-an-ad-users-login-without-password-vulnerability"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34379",
        "datePublished": "2022-09-01T18:45:18.835Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:13:20.117Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-24414 (GCVE-0-2022-24414)

    Vulnerability from cvelistv5 – Published: 2022-05-26 15:20 – Updated: 2024-09-17 00:55
    VLAI
    Summary
    Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks.
    CWE
    • CWE-598 - Information Exposure Through Query Strings in GET Request
    References
    Impacted products
    Vendor Product Version
    Dell CloudLink Affected: unspecified , < 7.1.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-16 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:13:55.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CloudLink",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "7.1.3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-03-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-598",
                  "description": "CWE-598: Information Exposure Through Query Strings in GET Request",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-26T15:20:17.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-03-16",
              "ID": "CVE-2022-24414",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CloudLink",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "7.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 7.6,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-598: Information Exposure Through Query Strings in GET Request"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000197425/dsa-2022-064-dell-emc-cloudlink-security-update-for-security-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-24414",
        "datePublished": "2022-05-26T15:20:17.669Z",
        "dateReserved": "2022-02-04T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:55:43.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }