Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for Traffix SDC by F5

    CVE-2022-27880 (GCVE-0-2022-27880)

    Vulnerability from nvd – Published: 2022-05-05 16:32 – Updated: 2024-09-17 04:00
    VLAI
    Summary
    On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    References
    Impacted products
    Vendor Product Version
    F5 Traffix SDC Affected: 5.2.x , < 5.2.2 (custom)
    Affected: 5.1.x , < 5.1.35 (custom)
    Create a notification for this product.
    Date Public
    2022-05-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:41:10.976Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.f5.com/csp/article/K17341495"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Traffix SDC",
              "vendor": "F5",
              "versions": [
                {
                  "lessThan": "5.2.2",
                  "status": "affected",
                  "version": "5.2.x",
                  "versionType": "custom"
                },
                {
                  "lessThan": "5.1.35",
                  "status": "affected",
                  "version": "5.1.x",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
            }
          ],
          "datePublic": "2022-05-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-05T16:32:33.000Z",
            "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
            "shortName": "f5"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.f5.com/csp/article/K17341495"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "f5sirt@f5.com",
              "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
              "ID": "CVE-2022-27880",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Traffix SDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.2.x",
                                "version_value": "5.2.2"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.1.x",
                                "version_value": "5.1.35"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "F5"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.f5.com/csp/article/K17341495",
                  "refsource": "MISC",
                  "url": "https://support.f5.com/csp/article/K17341495"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "assignerShortName": "f5",
        "cveId": "CVE-2022-27880",
        "datePublished": "2022-05-05T16:32:33.813Z",
        "dateReserved": "2022-04-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:00:20.047Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27662 (GCVE-0-2022-27662)

    Vulnerability from nvd – Published: 2022-05-05 16:29 – Updated: 2024-09-16 20:16
    VLAI
    Summary
    On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
    CWE
    • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
    References
    Impacted products
    Vendor Product Version
    F5 Traffix SDC Affected: 5.2.x , < 5.2.2 (custom)
    Affected: 5.1.x , < 5.1.35 (custom)
    Create a notification for this product.
    Date Public
    2022-05-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.915Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.f5.com/csp/article/K24248011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Traffix SDC",
              "vendor": "F5",
              "versions": [
                {
                  "lessThan": "5.2.2",
                  "status": "affected",
                  "version": "5.2.x",
                  "versionType": "custom"
                },
                {
                  "lessThan": "5.1.35",
                  "status": "affected",
                  "version": "5.1.x",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
            }
          ],
          "datePublic": "2022-05-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1336",
                  "description": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-05T16:29:10.000Z",
            "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
            "shortName": "f5"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.f5.com/csp/article/K24248011"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "f5sirt@f5.com",
              "DATE_PUBLIC": "2022-05-04T19:45:00.000Z",
              "ID": "CVE-2022-27662",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Traffix SDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.2.x",
                                "version_value": "5.2.2"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.1.x",
                                "version_value": "5.1.35"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "F5"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.f5.com/csp/article/K24248011",
                  "refsource": "MISC",
                  "url": "https://support.f5.com/csp/article/K24248011"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "assignerShortName": "f5",
        "cveId": "CVE-2022-27662",
        "datePublished": "2022-05-05T16:29:10.065Z",
        "dateReserved": "2022-04-19T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:16:37.864Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27880 (GCVE-0-2022-27880)

    Vulnerability from cvelistv5 – Published: 2022-05-05 16:32 – Updated: 2024-09-17 04:00
    VLAI
    Summary
    On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    References
    Impacted products
    Vendor Product Version
    F5 Traffix SDC Affected: 5.2.x , < 5.2.2 (custom)
    Affected: 5.1.x , < 5.1.35 (custom)
    Create a notification for this product.
    Date Public
    2022-05-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:41:10.976Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.f5.com/csp/article/K17341495"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Traffix SDC",
              "vendor": "F5",
              "versions": [
                {
                  "lessThan": "5.2.2",
                  "status": "affected",
                  "version": "5.2.x",
                  "versionType": "custom"
                },
                {
                  "lessThan": "5.1.35",
                  "status": "affected",
                  "version": "5.1.x",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
            }
          ],
          "datePublic": "2022-05-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-05T16:32:33.000Z",
            "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
            "shortName": "f5"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.f5.com/csp/article/K17341495"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "f5sirt@f5.com",
              "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
              "ID": "CVE-2022-27880",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Traffix SDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.2.x",
                                "version_value": "5.2.2"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.1.x",
                                "version_value": "5.1.35"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "F5"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.f5.com/csp/article/K17341495",
                  "refsource": "MISC",
                  "url": "https://support.f5.com/csp/article/K17341495"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "assignerShortName": "f5",
        "cveId": "CVE-2022-27880",
        "datePublished": "2022-05-05T16:32:33.813Z",
        "dateReserved": "2022-04-19T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:00:20.047Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27662 (GCVE-0-2022-27662)

    Vulnerability from cvelistv5 – Published: 2022-05-05 16:29 – Updated: 2024-09-16 20:16
    VLAI
    Summary
    On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
    CWE
    • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
    References
    Impacted products
    Vendor Product Version
    F5 Traffix SDC Affected: 5.2.x , < 5.2.2 (custom)
    Affected: 5.1.x , < 5.1.35 (custom)
    Create a notification for this product.
    Date Public
    2022-05-04 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.915Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.f5.com/csp/article/K24248011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Traffix SDC",
              "vendor": "F5",
              "versions": [
                {
                  "lessThan": "5.2.2",
                  "status": "affected",
                  "version": "5.2.x",
                  "versionType": "custom"
                },
                {
                  "lessThan": "5.1.35",
                  "status": "affected",
                  "version": "5.1.x",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
            }
          ],
          "datePublic": "2022-05-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1336",
                  "description": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-05T16:29:10.000Z",
            "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
            "shortName": "f5"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.f5.com/csp/article/K24248011"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "f5sirt@f5.com",
              "DATE_PUBLIC": "2022-05-04T19:45:00.000Z",
              "ID": "CVE-2022-27662",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Traffix SDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.2.x",
                                "version_value": "5.2.2"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "5.1.x",
                                "version_value": "5.1.35"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "F5"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.f5.com/csp/article/K24248011",
                  "refsource": "MISC",
                  "url": "https://support.f5.com/csp/article/K24248011"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "assignerShortName": "f5",
        "cveId": "CVE-2022-27662",
        "datePublished": "2022-05-05T16:29:10.065Z",
        "dateReserved": "2022-04-19T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:16:37.864Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }