Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for SCALANCE S612 by Siemens

    CVE-2019-6585 (GCVE-0-2019-6585)

    Vulnerability from nvd – Published: 2020-03-10 19:16 – Updated: 2024-08-04 20:23
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
    Severity
    No CVSS data available.
    CWE
    • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:23:22.461Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-80",
                  "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:19.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-6585",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-6585",
        "datePublished": "2020-03-10T19:16:17.000Z",
        "dateReserved": "2019-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:23:22.461Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13926 (GCVE-0-2019-13926)

    Vulnerability from nvd – Published: 2020-02-11 15:36 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-13926",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13926",
        "datePublished": "2020-02-11T15:36:10.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.805Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13925 (GCVE-0-2019-13925)

    Vulnerability from nvd – Published: 2020-02-11 15:36 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.784Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-13925",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13925",
        "datePublished": "2020-02-11T15:36:10.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13924 (GCVE-0-2019-13924)

    Vulnerability from nvd – Published: 2020-02-11 00:00 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
    Severity
    No CVSS data available.
    CWE
    • CWE-693 - Protection Mechanism Failure
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.919Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c 5.2.4"
                }
              ]
            },
            {
              "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.5.0"
                }
              ]
            },
            {
              "product": "SCALANCE X-200RNA switch family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.7"
                }
              ]
            },
            {
              "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c 4.1.3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693: Protection Mechanism Failure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-13T00:00:00.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
            },
            {
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13924",
        "datePublished": "2020-02-11T00:00:00.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.919Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6585 (GCVE-0-2019-6585)

    Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-04 20:23
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
    Severity
    No CVSS data available.
    CWE
    • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:23:22.461Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-80",
                  "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:19.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-6585",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-6585",
        "datePublished": "2020-03-10T19:16:17.000Z",
        "dateReserved": "2019-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:23:22.461Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13926 (GCVE-0-2019-13926)

    Vulnerability from cvelistv5 – Published: 2020-02-11 15:36 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-13926",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13926",
        "datePublished": "2020-02-11T15:36:10.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.805Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13925 (GCVE-0-2019-13925)

    Vulnerability from cvelistv5 – Published: 2020-02-11 15:36 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    References
    Impacted products
    Vendor Product Version
    Siemens SCALANCE S602 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S612 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S623 Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Siemens SCALANCE S627-2M Affected: All versions >= V3.0 and < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.784Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V3.0 and \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-13925",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SCALANCE S602",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S612",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S623",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S627-2M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V3.0 and \u003c V4.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13925",
        "datePublished": "2020-02-11T15:36:10.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13924 (GCVE-0-2019-13924)

    Vulnerability from cvelistv5 – Published: 2020-02-11 00:00 – Updated: 2024-08-05 00:05
    VLAI
    Summary
    A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
    Severity
    No CVSS data available.
    CWE
    • CWE-693 - Protection Mechanism Failure
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:05:43.919Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SCALANCE S602",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S612",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S623",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE S627-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c 5.2.4"
                }
              ]
            },
            {
              "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.5.0"
                }
              ]
            },
            {
              "product": "SCALANCE X-200RNA switch family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.7"
                }
              ]
            },
            {
              "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c 4.1.3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693: Protection Mechanism Failure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-13T00:00:00.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
            },
            {
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-13924",
        "datePublished": "2020-02-11T00:00:00.000Z",
        "dateReserved": "2019-07-18T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:05:43.919Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }