Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for SC-1000 WebConfig by ASSA ABLOY Seawing

    CVE-2026-97180 (GCVE-0-2026-97180)

    Vulnerability from nvd – Published: 2026-11-25 12:47 – Updated: 2026-11-25 16:44
    VLAI
    Title
    Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig
    Summary
    ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root user on the operating system. This issue was fixed in version 1.5.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-25 15:32 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Impacted products
    Vendor Product Version
    ASSA ABLOY Seawing SC-1000 WebConfig Affected: 0 , < 1.5.14 (semver)
        cpe:2.3:a:assa_abloy_seawing:sc-1000_webconfig:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-97180",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-25T15:32:21.852931Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-25T16:44:53.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SC-1000 WebConfig",
              "vendor": "ASSA ABLOY Seawing",
              "versions": [
                {
                  "lessThan": "1.5.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:assa_abloy_seawing:sc-1000_webconfig:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.5.14",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Maciej Kucab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Micha\u0142 Lipi\u0144ski"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root\u0026nbsp;user on the operating system.\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis issue was fixed in version 1.5.14.\u003c/div\u003e"
                }
              ],
              "value": "ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root\u00a0user on the operating system.\n\n\nThis issue was fixed in version 1.5.14."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T12:47:29.108Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2026/11/CVE-2026-97180"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.seawing.eu/hu/en/products/access-control/vezerlk1/sc-1000-termekcsalad"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.seawing.eu/hu/en/about-us/product-security-security-advisory"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig",
          "x_generator": {
            "engine": "Vulnogram 1.0.3"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2026-97180",
        "datePublished": "2026-11-25T12:47:29.108Z",
        "dateReserved": "2026-09-24T06:26:16.554Z",
        "dateUpdated": "2026-11-25T16:44:53.531Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-97180 (GCVE-0-2026-97180)

    Vulnerability from cvelistv5 – Published: 2026-11-25 12:47 – Updated: 2026-11-25 16:44
    VLAI
    Title
    Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig
    Summary
    ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root user on the operating system. This issue was fixed in version 1.5.14.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-25 15:32 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Impacted products
    Vendor Product Version
    ASSA ABLOY Seawing SC-1000 WebConfig Affected: 0 , < 1.5.14 (semver)
        cpe:2.3:a:assa_abloy_seawing:sc-1000_webconfig:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-97180",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-25T15:32:21.852931Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-25T16:44:53.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SC-1000 WebConfig",
              "vendor": "ASSA ABLOY Seawing",
              "versions": [
                {
                  "lessThan": "1.5.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:assa_abloy_seawing:sc-1000_webconfig:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.5.14",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Maciej Kucab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Micha\u0142 Lipi\u0144ski"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root\u0026nbsp;user on the operating system.\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis issue was fixed in version 1.5.14.\u003c/div\u003e"
                }
              ],
              "value": "ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root\u00a0user on the operating system.\n\n\nThis issue was fixed in version 1.5.14."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T12:47:29.108Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2026/11/CVE-2026-97180"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.seawing.eu/hu/en/products/access-control/vezerlk1/sc-1000-termekcsalad"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.seawing.eu/hu/en/about-us/product-security-security-advisory"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig",
          "x_generator": {
            "engine": "Vulnogram 1.0.3"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2026-97180",
        "datePublished": "2026-11-25T12:47:29.108Z",
        "dateReserved": "2026-09-24T06:26:16.554Z",
        "dateUpdated": "2026-11-25T16:44:53.531Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }