Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for R95 by D-Link

    CVE-2026-135789 (GCVE-0-2026-135789)

    Vulnerability from nvd – Published: 2026-11-24 16:30 – Updated: 2026-11-24 16:58
    VLAI
    Title
    D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection
    Summary
    A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-24 16:57 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/442752 vdb-entrytechnical-description
    https://vuldb.com/vuln/442752/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-135789 third-party-advisory
    https://vuldb.com/submit/1055810 third-party-advisory
    https://github.com/nenghun/IoT/blob/main/D-link%2… broken-linkexploit
    https://www.dlink.com/ product
    Impacted products
    Vendor Product Version
    D-Link R95 Affected: 101B06
        cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-135789",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-24T16:57:36.359861Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T16:58:46.331Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/1055810"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "DHMAPI SOAP Handler"
              ],
              "product": "R95",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "101B06"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "nenghun (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T16:30:22.766Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-442752 | D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/442752"
            },
            {
              "name": "VDB-442752 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/442752/cti"
            },
            {
              "name": "CVE-2026-135789 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-135789"
            },
            {
              "name": "Submit #1055810 | D-Link R95 (BE9500) R95A1_FW101B06 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1055810"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://github.com/nenghun/IoT/blob/main/D-link%20R95/rce.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T09:42:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-135789",
        "datePublished": "2026-11-24T16:30:22.766Z",
        "dateReserved": "2026-11-24T08:37:51.163Z",
        "dateUpdated": "2026-11-24T16:58:46.331Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-93958 (GCVE-0-2026-93958)

    Vulnerability from nvd – Published: 2026-09-20 01:15 – Updated: 2026-09-21 18:12
    VLAI
    Title
    D-Link R95 DHMAPI ssi system os command injection
    Summary
    A vulnerability was found in D-Link R95 BE9500_1.00.16. This vulnerability affects the function system of the file /bin/ssi of the component DHMAPI. The manipulation of the argument NTPServer results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-21 18:12 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/407917 vdb-entrytechnical-description
    https://vuldb.com/vuln/407917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-93958 third-party-advisory
    https://vuldb.com/submit/944149 third-party-advisory
    https://github.com/FoundTL/D-Link-R95-BE9500 exploit
    https://www.dlink.com/ product
    Impacted products
    Vendor Product Version
    D-Link R95 Affected: BE9500_1.00.16
        cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-93958",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-21T18:12:04.595932Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-21T18:12:35.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "DHMAPI"
              ],
              "product": "R95",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "BE9500_1.00.16"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Legion_TL (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in D-Link R95 BE9500_1.00.16. This vulnerability affects the function system of the file /bin/ssi of the component DHMAPI. The manipulation of the argument NTPServer results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-20T01:15:12.415Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-407917 | D-Link R95 DHMAPI ssi system os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/407917"
            },
            {
              "name": "VDB-407917 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/407917/cti"
            },
            {
              "name": "CVE-2026-93958 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-93958"
            },
            {
              "name": "Submit #944149 | DLink R95 1.01B06 CWE-78",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/944149"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/FoundTL/D-Link-R95-BE9500"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-19T11:17:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link R95 DHMAPI ssi system os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-93958",
        "datePublished": "2026-09-20T01:15:12.415Z",
        "dateReserved": "2026-09-19T09:12:08.815Z",
        "dateUpdated": "2026-09-21T18:12:35.896Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-135789 (GCVE-0-2026-135789)

    Vulnerability from cvelistv5 – Published: 2026-11-24 16:30 – Updated: 2026-11-24 16:58
    VLAI
    Title
    D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection
    Summary
    A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-24 16:57 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/442752 vdb-entrytechnical-description
    https://vuldb.com/vuln/442752/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-135789 third-party-advisory
    https://vuldb.com/submit/1055810 third-party-advisory
    https://github.com/nenghun/IoT/blob/main/D-link%2… broken-linkexploit
    https://www.dlink.com/ product
    Impacted products
    Vendor Product Version
    D-Link R95 Affected: 101B06
        cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-135789",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-24T16:57:36.359861Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T16:58:46.331Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/1055810"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "DHMAPI SOAP Handler"
              ],
              "product": "R95",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "101B06"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "nenghun (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T16:30:22.766Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-442752 | D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/442752"
            },
            {
              "name": "VDB-442752 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/442752/cti"
            },
            {
              "name": "CVE-2026-135789 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-135789"
            },
            {
              "name": "Submit #1055810 | D-Link R95 (BE9500) R95A1_FW101B06 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1055810"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://github.com/nenghun/IoT/blob/main/D-link%20R95/rce.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-24T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-24T09:42:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-135789",
        "datePublished": "2026-11-24T16:30:22.766Z",
        "dateReserved": "2026-11-24T08:37:51.163Z",
        "dateUpdated": "2026-11-24T16:58:46.331Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-93958 (GCVE-0-2026-93958)

    Vulnerability from cvelistv5 – Published: 2026-09-20 01:15 – Updated: 2026-09-21 18:12
    VLAI
    Title
    D-Link R95 DHMAPI ssi system os command injection
    Summary
    A vulnerability was found in D-Link R95 BE9500_1.00.16. This vulnerability affects the function system of the file /bin/ssi of the component DHMAPI. The manipulation of the argument NTPServer results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-21 18:12 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/407917 vdb-entrytechnical-description
    https://vuldb.com/vuln/407917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-93958 third-party-advisory
    https://vuldb.com/submit/944149 third-party-advisory
    https://github.com/FoundTL/D-Link-R95-BE9500 exploit
    https://www.dlink.com/ product
    Impacted products
    Vendor Product Version
    D-Link R95 Affected: BE9500_1.00.16
        cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-93958",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-21T18:12:04.595932Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-21T18:12:35.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "DHMAPI"
              ],
              "product": "R95",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "BE9500_1.00.16"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Legion_TL (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in D-Link R95 BE9500_1.00.16. This vulnerability affects the function system of the file /bin/ssi of the component DHMAPI. The manipulation of the argument NTPServer results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-20T01:15:12.415Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-407917 | D-Link R95 DHMAPI ssi system os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/407917"
            },
            {
              "name": "VDB-407917 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/407917/cti"
            },
            {
              "name": "CVE-2026-93958 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-93958"
            },
            {
              "name": "Submit #944149 | DLink R95 1.01B06 CWE-78",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/944149"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/FoundTL/D-Link-R95-BE9500"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-19T11:17:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link R95 DHMAPI ssi system os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-93958",
        "datePublished": "2026-09-20T01:15:12.415Z",
        "dateReserved": "2026-09-19T09:12:08.815Z",
        "dateUpdated": "2026-09-21T18:12:35.896Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }